Air conditioning is responsible for a considerable proportion of households’ electricity bills. During summer afternoons when households usually run their air conditioners, the retail time-of-use electricity tariffs are highest, and there is a peak demand in the electricity network. Pre-cooling is a method to shift air conditioning demand from peak hours to hours with lower demand and cheaper electricity tariffs. In this research, the pre-cooling potential of nine different types of residential housing in Sydney constructed with different star ratings and construction weights is evaluated. Star rating is the method to represent the annual heating and cooling requirements of buildings in Australia. Results highlight that pre-cooling produces cost saving for most of the days in 6-star and 8-star buildings. For 2-star buildings, pre-cooling sometimes leads to higher electricity costs. Moreover, pre-cooling improves thermal comfort, especially in 2-star light and medium weight buildings.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.