Breast cancer is the most common malignant tumor of females, the incidence increases with age. Bone is the most common site to which breast cancer metastasizes. Between 30% to 85% of patients with metastatic breast cancer develop bone metastases during the course of the disease. Bone scan is the most commonly used means of detecting bone metastasis; it visualizes increases in osteoblastic activity and skeletal vascularity. Many radio-pharmaceuticals (radionuclides) have been used in bone scan including technetium-99m bound to methylene diphosphonate (MDP). Published sensitivity and specificity rates of bone scan for diagnosis varies, with sensitivity ranging from 62% to 100% and specificity from 78% to 100%. However, bone scan is generally considered sensitive for detecting bone metastases on whole-body images.The aim of this study was to evaluate the pattern of distribution of skeletal metastases in patients with breast carcinoma by using Tc-99m MDP bone scan. A retrospective study was conducted on 245 consecutive female breast carcinoma patients irrespective of clinical staging, menopausal status and pre-operative / post- mastectomy status, referred for bone scan to Institute of Nuclear Medicine and Allied Sciences, Rajshahi from July 2015 to June 2017. The mean age of the patients was 43.4 ± 13.8 years (mean ± SD) with range from 29 to 66 years. Bone scan was performed by an intravenous bolus injection of 20 mCi Tc99m-MDP. Bone phase images were taken at three hours after injection of the radiotracer. Out of 245 studied patients, 163 patients (66.53%) were negative for skeletal metastasis and 82 patients (33.47%) were positive for skeletal metastasis. Out of 82 patients with positive skeletal metastasis, 68 (82.93%) patients had multiple sites (two or more) and 14 (17.07%) patients had solitary site of bony involvement. Out of 68 patients with multiple sites of skeletal metastasis, highest number was noted in thoraco-lumbar spine (80.89%), followed by ribs including sternum and clavicle (57.35%), pelvic bones (47.06%), upper extremities including scapula (41.18%), lower extremities (33.82%), cervical spine (23.53%) and skull bone (8.82%). Among 14 patients with solitary skeletal metastasis, maximum number was noted in thoraco-lumbar spine (64.29%), followed by cervical spine (14.29%), pelvic bone (07.14%), ribs (07.14%) and sternum (07.14%). Skeletal metastases were much more common in multiple sites than solitary lesion in breast cancer patients. Thoraco-lumbar spine was the most common site of involvement in both solitary and multiple lesions in our study. Axial skeleton was more commonly involved than the appendicular skeleton. Bone scan may pick up bone metastases up to 18 months earlier than conventional radiology, with an average lead of four months. 99m Tc- MDP bone scan is very cost effective in comparison to other imaging modalities (CT, MRI, and PET) and play a major role in early detection of skeletal metastasis in breast cancer patients. Bangladesh J. Nuclear Med. 21(1): 21-25, January 2018
<p><strong><em>Background: </em></strong>Lung cancer is the leading cause of cancer deaths worldwide. Lung cancer is often insidious, producing no symptoms until the disease is well advanced. In approximately 7-10% of cases, lung cancer is diagnosed in asymptomatic patients. Some patients are asymptomatic for skeletal metastasis and a recent prospective study showed that in staging of non-small cell lung cancer (NSCLC), failure to perform a bone scan could miss asymptomatic bone metastasis in 14–22% of patients. Radionuclide bone scintigraphy with <sup>99m</sup> Tc MDP (Technetium-99mmethylene diphosphonate) is very useful nuclear imaging tool to detect skeletal metastasis with a sensitivity of 98.2% and a specificity of 95.2%. The aim of this study was to detect the asymptomatic skeletal metastasis of non-small cell lung cancer patients by <sup>99m</sup>Tc MDP bone scan.</p><p><strong><em>Patients and methods:</em></strong> It is a retrospective study, carried out from January 2015 to December 2016 in Institute of Nuclear Medicine and Allied Sciences, Rajshahi. Bone scan was performed by an intravenous bolus injection of 20 m Ci <sup>99m</sup>Tc MDP. Bone phase images were taken at three hours after injection of the radiotracer.</p><p><strong><em>Results:</em></strong> A total of 52 patients were enrolled in the study. The mean age of the patients was 57.6 ± 14.5 years (mean ± SD) with range from 36 to 75 years and 42 (80.77%) were male and 10 (19.23%) were female. Out of 52 patients, only 06 (11.54%) patients were diagnosed as positive and 46 (88.46%) were negative for bone metastasis. Out of 06 patients with positive skeletal metastasis 04 (66.67%) patients had multiple sites (two or more) and 02 (33.33%) patients had solitary site of bone involvement. Common sites of metastasis were in thoracic (83.33%) and lumbar spine (83.33%), ribs (50%), pelvic bones (33.33%), long bones (16.66%), skull (16.66%) and other bony sites including clavicle, sternum, scapula, sacrum (16.66%). Regarding staging prior to bone scan, out of 06 bone scan positive patients 03 (50%) patients were in stage III, 02 (33.33%) patients were in stage IV and 01(16.67%) patient was in stage II. On the basis of histopathology, out of 06 skeletal metastatic patients 04 (66.67%) patients had adenocarcinoma, 01 (16.67%) patient had squamous cell carcinoma and 01 (16.67%) had large cell carcinoma. The exclusion of bone metastasis is important in the initial staging of non-small cell lung cancer.</p><p><strong><em>Conclusion:</em></strong> There is debate about whether bone scans should be performed routinely or restricted to patients who present with clinical or laboratory indicators suggesting skeletal metastasis. The present study indicates that if bone scans were done only in patients reporting skeletal symptoms an important number of patients (11.54%) would have been miss-staged due to asymptomatic bone metastasis. As bone scan is very cost effective in comparison to other imaging modalities (MRI / PET-CT), it can play a vital role in detecting asymptomatic skeletal metastasis in NSCLC patients.</p><p>Bangladesh J. Nuclear Med. 20(2): 110-114, July 2017</p>
This study highlights two cases having fused pelvic kidneys who were referred at this institute by clinicians/nephrologists for 99mTechnetium (99mTc) DMSA and DTPA renal scintigraphy. One case was 24 year old female and the other case was 21 year old male. Both cases were undergone ultrasonographic examination for correlative purpose before renal scintigraphy. Their urinary drainage system was assessed with DMSA and DTPA renal scintigraphy, showing normal functioning fused pelvic kidneys. The authors also used diuretic during DTPA renogram to exclude the true obstructive feature of urinary tract.TAJ 2016; 29(1): 55-57
Turning is one of the most widely accepted metal cutting processes in manufacturing industry. Due to global competitiveness, there is an increasing demand for product quality. Surface roughness represents the dimensional accuracy of the finished product and is one of the most important quality requirements of the finished product. Surface roughness is generally detrimental to the efficient performance of machined parts, especially where relative motion between parts is concerned. In this paper, a new novel technique has been proposed and adopted with an aim to reduce surface roughness of the machined surface. External ultrasonic sound waves were applied during the turning process of mild steel and its effect on surface quality was studied. Detailed experimentations were carried out under different ultrasonic frequencies to determine the effective frequency range which optimizes surface roughness to the best degree possible. The experimental results showed significant improvements in surface roughness in machined products. In addition to these, the effect of orientation of the application of the ultrasonic sound waves and the amplitude of the waves were studied in detail.
To study the variation of kidney counts, uptake and Glomerular filtration rate with renal split function, 27 patient’s renogram data were taken. Therefore, To investigate of glomerular filtration rate (GFR) for renal split function with 99mTc-DTPA.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.