Background Several clusters of serogroup C meningococcal disease among men who have sex with men (MSM) have been reported in the United States in recent years. The epidemiology and risk of meningococcal disease among MSM is not well described. Methods All meningococcal disease cases among men aged 18–64 years reported to the National Notifiable Disease Surveillance System between January 2012 and June 2015 were reviewed. Characteristics of meningococcal disease cases among MSM and men not known to be MSM (non-MSM) were described. Annualized incidence rates among MSM and non-MSM were compared through calculation of the relative risk and 95% confidence intervals. Isolates from meningococcal disease cases among MSM were characterized using standard microbiological methods and whole-genome sequencing. Results Seventy-four cases of meningococcal disease were reported among MSM and 453 among non-MSM. Annualized incidence of meningococcal disease among MSM was 0.56 cases per 100 000 population, compared to 0.14 among non-MSM, for a relative risk of 4.0 (95% confidence interval [CI], 3.1–5.1). Among the 64 MSM with known status, 38 (59%) were infected with human immunodeficiency virus (HIV). HIV-infected MSM had 10.1 times (95% CI, 6.1–16.6) the risk of HIV-uninfected MSM. All isolates from cluster-associated cases were serogroup C sequence type 11. Conclusions MSM are at increased risk for meningococcal disease, although the incidence of disease remains low. HIV infection may be an important factor for this increased risk. Routine vaccination of HIV-infected persons with a quadrivalent meningococcal conjugate vaccine in accordance with Advisory Committee on Immunization Practices recommendations should be encouraged.
We sought to estimate West Nile virus (WNV) activity in mosquito populations weekly at the census tract level in Chicago, IL, and to provide this information graphically. Each week we calculated a vector index (VI) for each mosquito trap then generated tract estimates using geographic information systems. During June 29-September 13, 2008, a median of 527 (60%) of 874 possible tracts per week had a VI value. Overall, 94% of the weekly VI tract estimates were 0; among those with a VI estimate greater than 0, the median was 0.33 (range 0.003-3.5). Officials deemed risk levels and weather conditions appropriate for adulticide treatments on 3 occasions, resulting in the treatment of approximately 252 linear kilometers of residential streets and alleys. Our analysis successfully converted complex, raw surveillance data into a format that highlighted areas of elevated WNV activity and facilitated the determination of appropriate response procedures.
Background. In August 2012, the Chicago Department of Public Health (CDPH) was notified of acute respiratory illness, including 1 fatality, among a group of meeting attendees who stayed at a Chicago hotel during July 30–August 3, 2012. Suspecting Legionnaires' disease (LD), CDPH advised the hotel to close their swimming pool, spa, and decorative lobby fountain and began an investigation.Methods. Case finding included notification of individuals potentially exposed during July 16–August 15, 2012. Individuals were interviewed using a standardized questionnaire. An environmental assessment was performed.Results. One hundred fourteen cases were identified: 11 confirmed LD, 29 suspect LD, and 74 Pontiac fever cases. Illness onsets occurred July 21–August 22, 2012. Median age was 48 years (range, 22–82 years), 64% were male, 59% sought medical care (15 hospitalizations), and 3 died. Relative risks for hotel exposures revealed that persons who spent time near the decorative fountain or bar, both located in the lobby were respectively 2.13 (95%, 1.64–2.77) and 1.25 (95% CI, 1.09–1.44) times more likely to become ill than those who did not. Legionella pneumophila serogroup 1 was isolated from samples collected from the fountain, spa, and women's locker room fixtures. Legionella pneumophila serogroup 1 environmental isolates and a clinical isolate had matching sequence-based types. Hotel maintenance records lacked a record of regular cleaning and disinfection of the fountain.Conclusions. Environmental testing identified Legionella in the hotel's potable water system. Epidemiologic and laboratory data indicated the decorative fountain as the source. Poor fountain maintenance likely created favorable conditions for Legionella overgrowth.
Rotavirus outbreaks can occur among adults, including young adults. Health professionals should consider rotavirus as a cause of acute gastroenteritis in adults.
Control in the Communicable Diseases Program. Her research interests include vaccine-preventable disease and sexual and reproductive health.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.