Objective Tocodynamometry (Toco—strain gauge technology) provides contraction frequency and approximate duration of labor contractions, but suffers frequent signal dropout necessitating re-positioning by a nurse, and may fail in obese patients. The alternative invasive intrauterine pressure catheter (IUPC) is more reliable and adds contraction pressure information, but requires ruptured membranes and introduces small risks of infection and abruption. Electrohysterography (EHG) reports the electrical activity of the uterus through electrodes placed on the maternal abdomen. This study compared all three methods of contraction detection simultaneously in laboring women. Study Design Upon consent, laboring women were monitored simultaneously with Toco, EHG, and IUPC. Contraction curves were generated in real-time for the EHG and all three curves were stored electronically. A contraction detection algorithm was used to compare frequency and timing between methods. Seventy-three subjects were enrolled in the study; 14 were excluded due to hardware failure of one or more of the devices (12) or inadequate data collection duration(2). Results In comparison with the gold-standard IUPC, EHG performed significantly better than Toco with regard to Contractions Consistency Index (CCI). The mean CCI for EHG was 0.88 ± 0.17 compared to 0.69 ± 0.27 for Toco (p<.0001). In contrast to Toco, EHG was not significantly affected by obesity. Conclusion Toco does not correlate well with the gold-standard IUPC and fails more frequently in obese patients. EHG provides a reliable non-invasive alternative regardless of body habitus.
The purpose of the study was to compare the accuracy of a noninvasive fetal heart rate monitor with that of ultrasound, using a fetal scalp electrode as the gold standard, in laboring women of varying body habitus, throughout labor and delivery. Laboring women requiring fetal scalp electrode were monitored simultaneously with the investigational device (noninvasive fetal ECG), ultrasound, and fetal scalp electrode. An algorithm extracted the fetal heart rate from the noninvasive fetal ECG signal. Each noninvasive device recording was compared with fetal scalp electrode with regard to reliability by positive percent agreement and accuracy by root mean squared error. Seventy-one women were included in this analysis. Positive percent agreement was 83.4 ± 15.4% for noninvasive fetal ECG and 62.4 ± 26.7% for ultrasound. The root mean squared error compared with fetal scalp electrode-derived fetal heart rate was 4.8 ± 2.0 bpm for noninvasive fetal ECG and 14.3 ± 8.2 bpm for ultrasound. The superiority of noninvasive fetal ECG was maintained for stages 1 and 2 of labor and increases in body mass index. Compared with fetal scalp electrode-derived fetal heart rate, noninvasive fetal ECG is more accurate and reliable than ultrasound for intrapartum monitoring for stages 1 and 2 of labor and is less affected by increasing maternal body mass index. This confirms the results of other workers in this field.
Objective The aim of this article was to compare clinical interpretation of uterine activity tracings acquired by tocodynamometry and electrohysterography with the gold standard, intrauterine pressure. Study Design Using data from a previous study, subjects who had simultaneous monitoring with all three uterine activity devices were included in this study. These were parturients who required intrauterine pressure catheter (IUPC) placement for obstetric indication. A Web-based application displayed scrolling 30-minute segments of uterine activity. Two blinded obstetricians and two blinded obstetric nurses independently reviewed the segments, marking uninterpretable segments and the peak of each contraction. Interpretability was compared using positive percent agreement. False positives are contractions marked in the noninvasive strip that have no corresponding contraction in the IUPC strip. False negatives are the reverse. Results A total of 135 segments, acquired during either Stage 1 (active labor) or Stage 2 (pushing), from 105 women, were included in this analysis. For all four observers, both interpretability and sensitivity of electrohysterography exceeded that of tocodynamometry (p < 0.0001). This remained true for the obese population (96 segments). Conclusion Compared with the IUPC, electrohysterography is more sensitive and provides tracings that are more often interpretable than tocodynamometry for intrapartum monitoring; electrohysterography is also less affected by increasing maternal body mass index.
Vascular parameters, as assessed noninvasively by photoplethysmography and heart rate variability, may have a role in screening women suspected of having preeclampsia, particularly in areas with limited resources.
BACKGROUND-The goal of this study was to determine a set of timing, shape, and statistical features available through non-invasive monitoring of maternal electrocardiogram and photoplethysmography that identifies preeclamptic patients.METHODS-Pregnant women admitted to Labor and Delivery were monitored with pulse oximetry and electrocardiogram for 30 min. Photoplethysmogram features and heart rate variability were extracted from each data set and applied to a sequential feature selection algorithm to discriminate women with preeclampsia with severe features, from normotensive and hypertensive controls. The classification boundary was chosen to minimize the expected misclassification cost. The prior probabilities of the misclassification costs were assumed to be equal.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.