Increased neck muscle activity and increased postural sway during simple balance tasks indicate disturbed sensory feedback patterns in people with whiplash-associated disorder, which may have negative consequences when performing daily activities.
BackgroundThere is a shortage of agreement studies relevant for measuring changes over time in lumbar intervertebral disc structures. The objectives of this study were: 1) to develop a method for measurement of intervertebral disc height, anterior and posterior disc material and dural sac diameter using MRI, 2) to evaluate intra- and inter-rater agreement and reliability for the measurements included, and 3) to identify factors compromising agreement.MethodsMeasurements were performed on MRIs from 16 people with and 16 without lumbar disc herniation, purposefully chosen to represent all possible disc contours among participants in a general population study cohort. Using the new method, MRIs were measured twice by one rater and once by a second rater. Agreement on the sagittal start- and end-slice was evaluated using weighted Kappa. Length and volume measurements were conducted on available slices between intervertebral foramens, and cross-sectional areas (CSA) were calculated from length measurements and slice thickness. Results were reported as Bland and Altman’s limits of agreement (LOA) and intraclass correlation coefficients (ICC).ResultsWeighted Kappa (Kw (95% CI)) for start- and end-slice were: intra-: 0.82(0.60;0.97) & 0.71(0.43;0.93); inter-rater: 0.56(0.29;0.78) & 0.60(0.35;0.81). For length measurements, LOA ranged from [−1.0;1.0] mm to [−2.0;2.3] mm for intra-; and from [−1.1; 1.4] mm to [−2.6;2.0] mm for inter-rater. For volume measurements, LOA ranged from [−293;199] mm3 to [−582;382] mm3 for intra-, and from [−17;801] mm3 to [−450;713] mm3 for inter-rater. For CSAs, LOA ranged between [−21.3; 18.8] mm2 and [−31.2; 43.7] mm2 for intra-, and between [−10.8; 16.4] mm2 and [−64.6; 27.1] mm2 for inter-rater. In general, LOA as a proportion of mean values gradually decreased with increasing size of the measured structures. Agreement was compromised by difficulties in identifying the vertebral corners, the anterior and posterior boundaries of the intervertebral disc and the dural sac posterior boundary. With two exceptions, ICCs were above 0.81.ConclusionsLength measurements and calculated CSAs of disc morphology and dural sac diameter from MRIs showed acceptable intra- and inter-rater agreement and reliability. However, caution should be taken when measuring very small structures and defining anatomical landmarks.
Impaired postural control and steadiness may only be quantifiable in individuals experiencing acute neck pain of certain intensity, and there may be a ceiling effect in the ability to improve these parameters. For individuals with highly developed physiological capacity, a battery of tests with more stringent demands should be considered, e.g., increased number of repetitions, prolonged duration of the tests, or testing with eyes closed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.