The aim of this study was to optimise the experimental protocol and data analysis for in-vivo breast cancer x-ray imaging. Results are presented of the experiment at the SYRMEP beamline of Elettra Synchrotron using the propagation-based phase-contrast mammographic tomography method, which incorporates not only absorption, but also x-ray phase information. In this study the images of breast tissue samples, of a size corresponding to a full human breast, with radiologically acceptable x-ray doses were obtained, and the degree of improvement of the image quality (from the diagnostic point of view) achievable using propagation-based phase-contrast image acquisition protocols with proper incorporation of x-ray phase retrieval into the reconstruction pipeline was investigated. Parameters such as the x-ray energy, sample-to-detector distance and data processing methods were tested, evaluated and optimized with respect to the estimated diagnostic value using a mastectomy sample with a malignant lesion. The results of quantitative evaluation of images were obtained by means of radiological assessment carried out by 13 experienced specialists. A comparative analysis was performed between the x-ray and the histological images of the specimen. The results of the analysis indicate that, within the investigated range of parameters, both the objective image quality characteristics and the subjective radiological scores of propagation-based phase-contrast images of breast tissues monotonically increase with the strength of phase contrast which in turn is directly proportional to the product of the radiation wavelength and the sample-to-detector distance. The outcomes of this study serve to define the practical imaging conditions and the CT reconstruction procedures appropriate for low-dose phase-contrast mammographic imaging of live patients at specially designed synchrotron beamlines.
Phase-contrast imaging depicts not only the absorption contrast but also the refraction contrast of the transmitted x-ray beam. Early data suggest that this new modality may overcome some of the diagnostic limitations associated with current clinically available mammography systems and that it has potential for improving breast cancer detection.
A method for extracting the dark-field signal in propagation-based phase-contrast imaging is proposed. In the case of objects consisting predominantly of a single material, or several different materials with similar ratios of the real decrement to the imaginary part of the complex refractive index, the proposed method requires a single image for extraction of the dark-field signal in two-dimensional projection imaging. In the case of three-dimensional tomographic imaging, the method needs only one image to be collected at each projection angle. Initial examples using simulated and experimental data indicate that this method can improve visualization of small sharp features inside a larger object, e.g. the visualization of microcalcifications in propagation-based x-ray breast cancer imaging. It is suggested that the proposed approach may be useful in other forms of biomedical imaging, where it can help one to obtain additional small-angle scattering information without increasing the radiation dose to the sample.
Purpose Propagation‐based phase‐contrast computed tomography (PB‐CT) is a method for three‐dimensional x‐ray imaging that utilizes refraction, as well as absorption, of x rays in the tissues to increase the signal‐to‐noise ratio (SNR) in the resultant images, in comparison with equivalent conventional absorption‐only x‐ray tomography (CT). Importantly, the higher SNR is achieved without sacrificing spatial resolution or increasing the radiation dose delivered to the imaged tissues. The present work has been carried out in the context of the current development of a breast CT imaging facility at the Australian Synchrotron. Methods Seven unfixed complete mastectomy samples with and without breast cancer lesions have been imaged using absorption‐only CT and PB‐CT techniques under controlled experimental conditions. The radiation doses delivered to the mastectomy samples during the scans were comparable to those approved for mammographic screening. Physical characteristics of the reconstructed images, such as spatial resolution and SNR, have been measured and compared with the results of the radiological quality assessment of the complete absorption CT and PB‐CT image stacks. Results Despite the presence of some image artefacts, the PB‐CT images have outperformed comparable absorption CT images collected at the same radiation dose, in terms of both the measured objective image characteristics and the radiological image scores. The outcomes of these experiments are shown to be consistent with predictions of the theory of PB‐CT imaging and previous reported experimental studies of this imaging modality. Conclusions The results presented in this paper demonstrate that PB‐CT holds a high potential for improving on the quality and diagnostic value of images obtained using existing medical x‐ray technologies, such as mammography and digital breast tomosynthesis (DBT). If implemented at suitable synchrotron imaging facilities, PB‐CT can be used to complement existing imaging modalities, leading to more accurate breast cancer diagnosis.
BackgroundIn this study, we explore the nexus between social networks and expertise development of Australian breast radiologists. Background literature has shown that a lack of appropriate social networks and interaction among certain professional group(s) may be an obstacle for knowledge acquisition, information flow and expertise sharing. To date there have not been any systematic studies investigating how social networks and expertise development are interconnected and whether this leads to improved performance for breast radiologists.MethodsThis study explores the value of social networks in building expertise alongside with other constructs of performance for the Australian radiology workforce using semi-structured in-depth interviews with 17 breast radiologists.ResultsThe findings from this study emphasise the influences of knowledge transfer and learning through social networks and interactions as well as knowledge acquisition and development through experience and feedback. The results also show that accessibility to learning resources and a variety of timely feedback on performance through the information and communication technologies (ICT) is likely to facilitate improved performance and build social support.ConclusionsWe argue that radiologists’ and, in particular, breast radiologists’ work performance, needs to be explored not only through individual numerical characteristics but also by analysing the social context and peer support networks in which they operate and we identify multidisciplinary care as a core entity of social learning.Electronic supplementary materialThe online version of this article (doi:10.1186/s12913-016-1938-9) contains supplementary material, which is available to authorized users.
The aim of this study was to highlight the advantages that propagation-based phase-contrast computed tomography (PB-CT) with synchrotron radiation can provide in breast cancer diagnostics. For the first time, a fresh and intact mastectomy sample from a 60 year old patient was scanned on the IMBL beamline at the Australian Synchrotron in PB-CT mode and reconstructed. The clinical picture was described and characterized by an experienced breast radiologist, who underlined the advantages of providing diagnosis on a PB-CT volume rather than conventional two-dimensional modalities. Subsequently, the image quality was assessed by 11 breast radiologists and medical imaging experts using a radiological scoring system. The results indicate that, with the radiation dose delivered to the sample being equal, the accuracy of a diagnosis made on PB-CT images is significantly higher than one using conventional techniques.
In this study we demonstrate the first direct comparison between synchrotron x-ray propagation-based CT (PB-CT) and cone-beam breast-CT (CB-CT) on human mastectomy specimens (N = 12) including different benign and malignant lesions. The image quality and diagnostic power of the obtained data sets were compared and judged by two independent expert radiologists. Two cases are presented in detail in this paper including a comparison with the corresponding histological evaluation. Results indicate that with PB-CT it is possible to increase the level of contrast-to-noise ratio (CNR) keeping the same level of dose used for the CB-CT or achieve the same level of CNR reached by CB-CT at a lower level of dose. In other words, PB-CT can achieve a higher diagnostic potential compared to the commercial breast-CT system while also delivering a considerably lower mean glandular dose. Therefore, we believe that PB-CT technique, if translated to a clinical setting, could have a significant impact in improving breast cancer diagnosis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.