A total of 13 ferroconcrete slab specimens reinforced by composite mortar were used to conduct a strength performance evaluation with the types of reinforcement and the diameter of wire meshes as its parameters to determine failure modes, ductility and stiffness. A total of six floor impact noise tests based on KS F 2810-2:2012 were performed at the construction site of H apartment complex, which had just completed frame construction. The study used Ethylene-Vinyl Acetate Copolymer (EVA), Expanded Polystyrene (EPS), and Polypropylene (PP) as the reinforcement materials effective against floor impact noise, and employed the gridshaped steel wire meshes for improving strength performance.The test results showed that in the case of the reinforced slab specimens, there was no detachment of reinforcement materials like the wire meshes and composite mortar thanks to the bonding force of anchor bolts and composite mortar. Under the maximum strength, the EVA-reinforced slab specimen was the most effective by improving the heavyweight floor impact noise by 23% and the lightweight floor impact noise by 12%.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.