The provided electrophysiological and immunohistochemical data provide strong support to the viability of the developed probe technology. Furthermore, the obtained data provide insights into further optimization of the probe design, including tip geometry, use of neurotrophic and anti-inflammatory drugs in the Matrigel coating, and placement of the recording sites.
A Parylene C neural probe with a three dimensional sheath structure was designed, fabricated, and characterized. Multiple platinum (Pt) electrodes for recording neural signals were fabricated on both inner and outer surfaces of the sheath structure. Thermoforming of Parylene was used to create the three dimensional sheath structures from flat surface micromachined microchannels using solid microwires as molds. Benchtop electrochemical characterization was performed on the thin film Pt electrodes using cyclic voltammetry and electrochemical impedance spectroscopy and showed that electrodes possessed low impedances suitable for neuronal recordings. A procedure for implantation of the neural probe was developed and successfully demonstrated in vitro into an agarose brain tissue model. The electrode-lined sheath will be decorated with eluting neurotrophic factors to promote in vivo neural tissue ingrowth post-implantation. These features will enhance tissue integration and improve recording quality towards realizing reliable chronic neural interfaces.
The Barostim neo™ electrode was developed by CVRx, Inc.to deliver baroreflex activation therapy (BAT)™ to treat hypertension and heart failure. The neo electrode concept was designed to deliver electrical stimulation to the baroreceptors within the carotid sinus bulb, while minimizing invasiveness of the implant procedure. This device is currently CE marked in Europe, and in a Pivotal (akin to Phase III) Trial in the United States. Here we present the in vitro and in vivo safety testing that was completed in order to obtain necessary regulatory approval prior to conducting human studies in Europe, as well as an FDA Investigational Device Exemption (IDE) to conduct a Pivotal Trial in the United States. Stimulated electrodes (10 mA, 500 μs, 100 Hz) were compared to unstimulated electrodes using optical microscopy and several electrochemical techniques over the course of 27 weeks. Electrode dissolution was evaluated by analyzing trace metal content of solutions in which electrodes were stimulated. Lastly, safety testing under Good Laboratory Practice guidelines was conducted in an ovine animal model over a 12 and 24 week time period, with results processed and evaluated by an independent histopathologist. Long-term stimulation testing indicated that the neo electrode with a sputtered iridium oxide coating can be stimulated at maximal levels for the lifetime of the implant without clinically significant dissolution of platinum or iridium, and without increasing the potential at the electrode interface to cause hydrolysis or significant tissue damage. Histological examination of tissue that was adjacent to the neo electrodes indicated no clinically significant signs of increased inflammation and no arterial stenosis as a result of 6 months of continuous stimulation. The work presented here involved rigorous characterization and evaluation testing of the neo electrode, which was used to support its safety for chronic implantation. The testing strategies discussed provide a starting point and proven framework for testing new neuromodulation electrode concepts to support regulatory approval for clinical studies.
The PSEA demonstrates the scalability of sheath electrode technology and provides higher electrode count and density to access a greater volume for recording. This study provided support for the importance of creating a supportive biological environment around the probes to promote the long-term electrophysiological performance of flexible probes in the cerebral cortex. In particular, we demonstrated beneficial effects of the Matrigel coating and the long-term expression of Caveolin-1. Furthermore, we provided support to an idea of using an artificial acellular tissue compartment as a way to counteract the walling-off effect of the astrocytic scar formation around the probes as a means of establishing a more intimate and stable neural interface.
Carbon-based electrodes combined with fast-scan cyclic voltammetry (FSCV) enable neurochemical sensing with high spatiotemporal resolution and sensitivity. While their attractive electrochemical and conductive properties have established a long history of use in the detection of neurotransmitters both in vitro and in vivo, carbon fiber microelectrodes (CFMEs) also have limitations in their fabrication, flexibility, and chronic stability. Diamond is a form of carbon with a more rigid bonding structure (sp3-hybridized) which can become conductive when boron-doped. Boron-doped diamond (BDD) is characterized by an extremely wide potential window, low background current, and good biocompatibility. Additionally, methods for processing and patterning diamond allow for high-throughput batch fabrication and customization of electrode arrays with unique architectures. While tradeoffs in sensitivity can undermine the advantages of BDD as a neurochemical sensor, there are numerous untapped opportunities to further improve performance, including anodic pretreatment, or optimization of the FSCV waveform, instrumentation, sp2/sp3 character, doping, surface characteristics, and signal processing. Here, we review the state-of-the-art in diamond electrodes for neurochemical sensing and discuss potential opportunities for future advancements of the technology. We highlight our team’s progress with the development of an all-diamond fiber ultramicroelectrode as a novel approach to advance the performance and applications of diamond-based neurochemical sensors.
The biologically derived hydrogel Matrigel (MG) was used to coat a Parylene-based sheath intracortical electrode to act as a mechanical and biological buffer as well as a matrix for delivering bioactive molecules to modulate the cellular response and improve recording quality. MG was loaded with dexamethasone to reduce the immune response together with nerve growth factor (NGF) and brain-derived neurotrophic factor (BDNF) to maintain neuronal density and encourage neuronal ingrowth toward electrodes within the sheath. Coating the Parylene sheath electrode with the loaded MG significantly improved the signal-to-noise ratio for neural events recorded from the motor cortex in rat for more than 3 months. Electron microscopy showed even coverage of both the Parylene substrate and the platinum recording electrodes. Electrochemical impedance spectroscopy (EIS) of coated electrodes in 1× phosphate-buffered saline demonstrated low impedance required for recording neural signals. This result was confirmed by in vivo EIS data, showing significantly decreased impedance during the first week of recording. Dexamethasone, NGF, and BDNF loaded into MG were released within 1 day in 1× phosphate-buffered saline. Although previous studies showed that MG loaded with either the immunosuppressant or the neurotrophic factor cocktail provided modest improvement in recording quality in a 1-month in vivo study, the combination of these bioactive molecules did not improve the signal quality over coating probes with only MG in a 3-month in vivo study. The MG coating may further improve recording quality by optimizing the in vivo release profile for the bioactive molecules.
Implantable devices to measure neurochemical or electrical activity from the brain are mainstays of neuroscience research and have become increasingly utilized as enabling components of clinical therapies. In order to increase the number of recording channels on these devices while minimizing the immune response, flexible electrodes under 10 µm in diameter have been proposed as ideal next-generation neural interfaces. However, the representation of motion artifact during neurochemical or electrophysiological recordings using ultra-small, flexible electrodes remains unexplored. In this short communication, we characterize motion artifact generated by the movement of 7 µm diameter carbon fiber electrodes during electrophysiological recordings and fast-scan cyclic voltammetry (FSCV) measurements of electroactive neurochemicals. Through in vitro and in vivo experiments, we demonstrate that artifact induced by motion can be problematic to distinguish from the characteristic signals associated with recorded action potentials or neurochemical measurements. These results underscore that new electrode materials and recording paradigms can alter the representation of common sources of artifact in vivo and therefore must be carefully characterized.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.