Purpose. This study evaluated the influence of recycling process on the torsional strength of mini-implants. Materials and Methods. Two hundred mini-implants were divided into 4 groups with 50 screws equally distributed in five diameters (1.3 to 1.7 mm): control group (CG): unused mini-implants, G1: mini-implants inserted in pig iliac bone and removed, G2: same protocol of group 1 followed by sonication for cleaning and autoclave sterilization, and G3: same insertion protocol of group 1 followed by sonication for cleaning before and after sandblasting (Al2O3-90 µ) and autoclave sterilization. G2 and G3 mini-implants were weighed after recycling process to evaluate weight loss (W). All the screws were broken to determine the fracture torque (FT). The influence of recycling process on FT and W was evaluated by ANOVA, Mann-Whitney, and multiple linear regression analysis. Results. FT was not influenced by recycling protocols even when sandblasting was added. Sandblasting caused weight loss due to abrasive mechanical stripping of screw surface. Screw diameter was the only variable that affected FT. Conclusions. Torsional strengths of screws that underwent the recycling protocols were not changed. Thus, screw diameter choice can be a more critical step to avoid screw fracture than recycling decision.
BackgroundThe purpose of this study was to compare the occlusal stability of class II subdivision malocclusion treatment with 3 and 4 first premolar extractions. A sample of 156 dental casts from 52 patients with class II subdivision malocclusion was divided into two groups according to the extraction protocol. Group 1 comprised 24 patients treated with 3 premolar extractions and group 2 included 28 patients treated with 4 premolar extractions.MethodsPeer assessment rating (PAR) indexes were measured on the dental casts obtained before (T1) and after treatment (T2) and at a mean of 6.9 years after the end of treatment (T3). The groups were matching regarding sex distribution, pretreatment, posttreatment and long-term posttreatment ages, and treatment and long-term posttreatment times. They were also comparable concerning the initial malocclusion severity and the occlusal results at the end of treatment. Stability evaluation was calculated by subtracting the posttreatment from the long-term posttreatment index values (T3 − T2). T tests were used to compare the amount and percentage of long-term posttreatment changes.ResultsThere were no intergroup differences regarding the amount and percentage of long-term posttreatment changes.ConclusionTreatment of class II subdivision malocclusion with 3 and 4 premolar extractions have a similar long-term posttreatment occlusal stability.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.