BACKGROUND AND PURPOSE:Tinnitus is a common disorder, and the etiology remains mostly unclear. The purpose of this study was to investigate the causative effect of the vascular loop and compression of the vestibulocochlear nerve at the cerebellopontine angle in patients with unexplained tinnitus.
Popliteal artery entrapment (PAE) syndrome is an uncommon congenital anomaly seen in young adults causing ischemic symptoms in the lower extremities. It is the result of various types of anomalous relationships between the popliteal artery and the neighboring muscular structures. The purpose of this study was to define the role of MR imaging combined with MR angiography in the diagnosis of PAE cases. Four cases with segmental occlusion and medial displacement of popliteal artery in digital subtraction angiography (DSA) examinations were diagnosed as PAE syndrome by MR imaging and MR angiography. The DSA and MRA images are compared. All of the cases showed various degrees of abnormal intercondylar insertion of the medial head of the gastrocnemius muscle. The MR images showed detailed anatomy of the region revealing the cause of the arterial entrapment. Subclassification of the cases were done and fat tissue filling the normal localization of the muscle was evaluated. The DSA and MRA images demonstrated the length and localization of the occluded segment and collateral vascular developments equally. It is concluded that angiographic evaluation alone in PAE syndrome might result in overlooking the underlying cause of the arterial occlusion, which in turn leads to unsuccessful therapy procedures such as balloon angioplasty. Magnetic resonance imaging combined with MR angiography demonstrates both the vascular anatomy and the variations in the muscular structures in the popliteal fossa successfully, and this combination seems to be the most effective way of evaluating young adults with ischemic symptoms suggesting PAE syndrome.
Primary stenting is an effective and reliable approach for complex plaques in stenoses. Patency of the arterial segment with a smooth lumen can be created without the risk of acute complications such as distal embolization, dissection, or occlusion.
We report a retrospective study to determine the cost-effectiveness of cranial computed tomography in patients with headache without neurological finding. Five hundred ninety-two neurologically normal patients were examined between 1990 and 1993 for the complaint of headache. Examination results were reevaluated from written report and image archive systems. Results were divided into three groups. In group P0, we included patients with normal cranial computed tomography findings. In group P1, patients showed some minor pathologies like ischemic or atrophic changes. These findings neither explained the reason for headache nor changed the clinical or therapeutic approach. The third group (P2) was to include patients with gross intracranial pathology like space-occupying lesions or bleeding. Five hundred forty-six of 592 patients were in the P0 group (92%), and the remaining 46 patients were in the P1 group (8%). No patient was found to have serious intracranial pathology detected by computed tomography. Cost of detection of a case with significant pathology was calculated. It is our opinion that computed tomography is an unrewarding technique in the evaluation of patients with chronic headache whose neurological examinations are normal.
BACKGROUND AND PURPOSE:The endovascular treatment of aneurysms located at or distal to the circle of Willis and not amenable to coiling remains a challenge. We report our experience with flow-diversion treatment using low-profile braided stents as a stent monotherapy procedure for treating distally located very small or uncoilable aneurysms.
Our results with a mean follow-up 18.5 months suggest that stent-graft implantation for the closure of postcatheterization femoral AVFs originating from the deep femoral artery is an effective, minimally invasive alternative procedure.
Introduction and Objective. Disadvantages associated with direct high b-value measurements may be avoided with use of computed diffusion-weighted imaging (cDWI). The purpose of this study is to assess the diagnostic performance of cDWI image sets calculated for high b-values of 1500, 2000, and 3000 s/mm2. Materials and Methods. Twenty-eight patients who underwent multiparametric MRI of the prostate and radical prostatectomy consecutively were enrolled in this retrospective study. Using a software developed at our institute, cDWI1500, cDWI2000, and cDWI3000 image sets were generated by fitting a monoexponential model. Index lesions on cDWI image sets were scored by two radiologists in consensus considering lesion conspicuity, suppression of background prostate tissue, distortion, image set preferability, and contrast ratio measurements were performed. Results. Lesion detection rates are the same for computed b-values of 2000 and 3000 s/mm2 and are better than b-values of 1500 s/mm2. Best lesion conspicuity and best background prostate tissue suppression are provided by cDWI3000 image set. cDWI2000 image set provides the best zonal anatomical delineation and less distortion and was chosen as the most preferred image set. Average contrast ratio measured on these image sets shows almost a linear relation with the b-values. Conclusion. cDWI2000 image set with similar conspicuity and the same lesion detection rate, but better zonal anatomical delineation, and less distortion, was chosen as the preferable image set.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.