Objectives: A long-lasting legionellosis outbreak was reported between November 2011 and July 2012 in a hotel in Calpe (Spain) affecting 44 patients including six deaths. Intensive epidemiological and microbiological investigations were performed in order to detect the reservoirs.Methods: Clinical and environmental samples were tested for the presence and genetic characterization of Legionella pneumophila. Six of the isolates were subjected to whole-genome sequencing.Results: Sequencing of 14 clinical and 260 environmental samples revealed sequence type (ST) 23 as the main responsible strain for the infections. This ST was found in the spa pool, from where it spread to other hotel public spaces, explaining the ST23 clinical cases, including guests who had not visited the spa. Uncultured clinical specimens showed profiles compatible with ST23, ST578, and mixed patterns. Profiles compatible with ST578 were obtained by direct sequencing from biofilm samples collected from the domestic water system, which provided evidence for the source of infection for non ST23 patients. Whole genome data from five ST23 strains and the identification of different STs and Legionella species showed that different hotel premises were likely colonized since the hotel opening thus explaining how different patients had been infected by distinct STs.Conclusions: Both epidemiological and molecular data are essential in the investigation of legionellosis outbreaks. Whole-genome sequencing data revealed significant intra-ST variability and allowed to make further inference on the short-term evolution of a local colonization of L. pneumophila.
A total of 63 families with Huntington disease (HD) were examined for linkage between HD and G8 (D4S10). The families included 57 Caucasian, four Black American, and two Japanese. The combined maximum lod score was 87.69 at theta = 0.04 (99% confidence interval 0.018-0.071). The maximum frequency of recombination was 0.03 in males and 0.05 in females. Fifty-seven families gave positive lod scores; five small families gave mildly negative lod scores. The maximum likelihood estimate of alpha, the proportion of linked loci, was 1.0 with a lower 99% confidence interval of 0.88. These data suggest that there is only one HD locus, although a second rare locus cannot be ruled out.
According to European Guidelines for Legionnaires’ Disease prevention and control, travel-associated Legionnaires’ disease (TALD) cases are managed differently if classified as sporadic or as part of a cluster and more stringent control measures are deployed after clusters are identified. In this study, we propose to modify the current cluster definition: ‘two or more cases of Legionnaires’ disease (LD) who stayed at, or visited, the same commercial accommodation site 2–10 days before onset of illness and whose onset is within the same 2-year period’ with a new cluster definition, i.e. accommodation sites associated with multiple cases regardless of the time elapsed between them. TALD cases occurred in Italy and in the Balearic Islands between 2005 and 2015 were analysed applying the current European Legionnaires’ Disease Surveillance Network (ELDSNet) cluster definition. In a sample of selected accommodation sites with multiple cases, a microbiological study was also conducted. Using the new definition, 63 additional sites (16.4% increase) and 225 additional linked cases (19.5% increase) were identified. Legionella pneumophila sg1 was isolated from 90.7% of the selected accommodation sites. The use of the here proposed TALD cluster definition would warrant a full investigation for each new identified case. This approach should therefore increase the number of sites that will require a risk assessment and, in the presence of an increased risk, the adoption of LD control measures to hopefully prevent additional cases.
Different guidelines and regulations for the prevention of legionellosis in public facilities include the recommendation of a periodical thermal shock in the hot water system. The purpose of this study was to assess the efficacy of periodical thermal shocks along a 1-year period on the presence of Legionella spp. in the domestic hot water system of hotels. The Legionella testing results from the period January–December 2019 coming from a group of 77 hotel facilities in the Balearic Islands (Spain) conducting periodical thermal shocks were analyzed. A second group of 44 hotels operating without periodical thermal shocks was used for a comparative analysis. In the facilities where the periodical thermal shock was performed, 16.0% of the results (429 hot water samples collected) were positive for Legionella spp., compared to 21.1% (298 samples), where periodical thermal shock was not performed. Overall, in the thermal shock group, 32.5% of the sites presented at least 1 positive sample along the period of study versus 45.5% in the control group. None of these differences was statistically significant (p-value > 0.05). These findings suggest that the efficacy of regular thermal shock for long-term control of Legionella spp. in domestic hot water systems of hotels is low.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.