Background Numerous fast threshold strategies have been developed in perimetry which use maximum likelihood approaches to estimate the threshold. A recent approach to threshold estimation has been developed estimating the threshold from a limited number of test points which further reduces examination time. This strategy, SPARK, has not been compared to the SITA strategy. The aim of this study was to compare SPARK with SITA in a normal cohort to evaluate within and between strategy agreement in threshold estimates. Methods A total of 83 normal subjects each underwent two visual field examinations with SITA and SPARK on two separate occasions on a randomly selected eye. The eye examined and the order of strategy examined first was randomised but remained constant over the two perimetry visits. Results Visual field examination with SPARK Precision was on average 33% faster than SITA Standard. A positive correlation between group mean sensitivities of SITA Standard and SPARK Precision (rho = 0.713, p < 0.001) was found. In total, 95% of stimulus locations were located within the 95% limits of agreement and linear regression on the differences in sensitivities showed no statistically significant proportional bias (t = 1.713, p = 0.09). Pointwise analysis showed SITA Standard had significantly larger variability for individual stimulus locations examined over two visits when compared to SPARK (t = 9.175, p < 0.001). Conclusion The clinical examination of SPARK yields a sensitivity profile similar to SITA but in a faster examination time. The lower threshold variability of SPARK may be as a result of data smoothing in the threshold estimation process.
Purpose The aims of this paper were to examine focal and diffuse visual field loss in terms of threshold agreement between the widely used SITA Standard Humphrey Field Analyser (HFA) threshold algorithm with the SPARK Precision algorithm (Oculus Twinfield 2). Methods A total of 39 treated glaucoma patients (34 primary open angle and 5 primary angle closure glaucoma) and 31 cataract patients without glaucoma were tested in succession with the Oculus Twinfield 2 (Oculus Optikgeräte GmbH, Wetzlar, Germany) using the SPARK Precision algorithm and with the HFA 3 (Carl Zeiss Meditec, Dublin, CA) using the 30–2 SITA Standard algorithm. Results SPARK Precision required around half the testing time of SITA Standard. There was a good correlation between the MS of the two threshold algorithms but MD and PSD were significantly less severe with SPARK Precision in both glaucoma (focal field loss) and cataract (diffuse field loss) groups (p < 0.001). There was poor agreement for all global indices (MS, MD and PSD) between the two algorithms and there was a significant proportional bias of MD in the glaucoma group and PSD in both glaucoma and cataract groups. The pointwise sensitivity analysis yielded higher threshold estimates in SPARK Precision than in SITA Standard in the nasal field. Classification of glaucoma severity using AGIS was significantly lower with SPARK Precision compared to SITA Standard (p < 0.001). Conclusion SITA renders deeper defects than SPARK. Compared to the SITA Standard threshold algorithm, SPARK Precision cannot quantify early glaucomatous field loss. This may be due to the mathematical linear interpolation of threshold sensitivity or deeper scotomas due to the plateau effect caused by the reduced dynamic range of the Twinfield 2 perimeter. Although not of clinical significance in early glaucoma, the plateau effect may hinder the long-term follow-up of patients during disease progression.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.