Background and study aim
Different types of endoscopic ultrasound (EUS)-guided fine-needle aspiration (FNA) techniques are used in clinical practice; the best method in terms of outcome has not been determined. The aim of the study was to compare the diagnostic adequacy of aspirated material, and the cytopathological and EUS morphological features between capillary action, suction, and no-suction FNA methods.
Patients and methods
This was a prospective, single-blinded, randomized study conducted at a tertiary care hospital. Patients were randomized to the three groups: capillary action, suction, and no suction. A total of 300 patients were included, with 100 patients in each arm.
Results
A total of 300 patients (195 males) underwent EUS-FNA of 235 lymph nodes and 65 pancreatic masses (distribution not statistically different between the groups). The mean age was 52 ± 14 years. A 22 gauge needle was used in the majority (93 %) of procedures. There was no statistical difference between the three groups regarding lymph node size at the largest axis and ratio, type of needle, echo features, echogenicity, calcification, necrosis, shape, borders (lymph nodes), number of passes, and cellularity. Diagnostic adequacy of the specimen was 91 %, 91 %, and 94 % in the capillary, suction, and no suction groups, respectively (
P
= 0.67). Significantly more slides and blood clots were generated by the suction method compared with the other methods.
Conclusion
The capillary action, suction, and no suction methods of EUS-FNA are similar in terms of diagnostic adequacy of the specimen. The suction method has the disadvantages of causing more bleeding and generating more slides.
Background and aims
Endoscopic ultrasound (EUS) guided drainage of symptomatic pancreatic walled-off necrosis (WON) followed by fully covered self-expanding metal stent (FCSEMS) placement offers several advantages such as higher technical success rate and the option of necrosectomy. The aim of this study was to evaluate the safety and efficacy of EUS guided drainage of patients with WON by using FCSEMS and intracavitary lavage with a solution containing hydrogen peroxide and adopting a step-up approach.
Methods
A prospective open label study was carried out at a single tertiary care center between January 2014 and January 2016. Patients with symptomatic WON who underwent EUS guided drainage followed by FCSEMS placement were included. Primary end points were complete drainage with improvement in symptoms or major adverse events. Secondary end points were minor adverse events related to the procedures.
Results
A total of 64 patients (mean age 36 years; 52 males) were included. Technical success was achieved in 100 % of patients and clinical success was achieved in 90.6 %. Complete drainage was achieved with FCSEMS alone in 18 (28.1 %), FCSEMS with necrosectomy using lavage in 40 (62.5 %), FCSEMS with percutaneous drainage (PCD) in 5 (7.8 %), and 1 (1.6 %) patient required salvage surgery. The major adverse event was life threatening bleeding in 3 (4.7 %) patients. Minor adverse events were non-life threatening bleeding in 2 (3.1 %) patients and stent migration in 3 (4.7 %) patients.
Conclusion
EUS guided WON drainage with FCSEMS followed by necrosectomy with lavage using a solution containing hydrogen peroxide as a step-up approach is a minimally invasive and effective method with a high technical and clinical success rate. Patients with solid debris > 40 % need aggressive management.
Background and study aims
The role of endoscopic-ultrasound (EUS) guided fine-needle aspiration (FNA) in patients with lymphadenopathy in terms of diagnostic adequacy and safety in large population is not well defined. The aim of this study was to evaluate diagnostic adequacy and safety of EUS-FNA in patients with lymphadenopathy.
Patients and methods
Retrospective study from October 2010 to September 2015 at tertiary care center in Delhi-NCR. We analyzed data from 1005 EUS- FNAs of lymph nodes.
Results
The study cohort comprised 1005 lymph nodes in 865 patients; 68 % were males, mean age was 50 ± 14 years. Indications of FNA were to look for etiology of pyrexia of unknown origin or staging of malignancy mainly. FNA was taken from mediastinal nodes (n = 528, 52.5 %) and intra-abdominal nodes (n = 477, 47.5 %). Median size of nodes at long axis and short axis was 17 (12 – 25.7) and 10 (8 – 15) mm respectively. Adequate material by FNA was obtained in 92.8 % cases. The cytopathologic diagnosis were malignancy in 153 (15.2 %), granulomatous change in 452 (42 %), and reactive lymphadenopathy in 328 (35.6 %). There was statistically significant difference seen between groups with pathological and reactive lymph nodes regarding size at long and short axis, hypoechoic nature, well defined borders and presence of necrosis and calcification. Procedure-related adverse effects were encountered in 6 patients (0.8 %). Four patients had mild mucosal bleeding in chronic liver disease patients and two had mild hepatic encephalopathy related to sedation.
Conclusion
EUS-FNA of lymph nodes has good diagnostic adequacy and safety.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.