Background: Deep learning (DL) has shown promising results in improving atrial fibrillation (AF) detection algorithms. However, these models are often criticized because of their "black box" nature. Aim: To develop a morphology based DL model to discriminate AF from sinus rhythm (SR), and to visualize which parts of the ECG are used by the model to derive to the right classification. Methods: We pre-processed raw data of 1469 ECGs in AF or SR, of patients with a history AF. Input data was generated by normalizing all single cycles (SC) of one ECG lead to SC-ECG samples by 1) centralizing the R wave or 2) scaling from R-to-R wave. Different DL models were trained by splitting the data in a training, validation and test set. By using a DL based heat mapping technique we visualized those areas of the ECG used by the classifier to come to the correct classification.Results: The DL model with the best performance was a feedforward neural network trained by SC-ECG samples on a R-to-R wave basis of lead II, resulting in an accuracy of 0.96 and F1-score of 0.94. The onset of the QRS complex proved to be the most relevant area for the model to discriminate AF from SR.
Conclusion:The morphology based DL model developed in this study was able to discriminate AF from SR with a very high accuracy. DL model visualization may help clinicians gain insights into which (unrecognized) ECG features are most sensitive to discriminate AF from SR.
Introduction: The two-incision implantation technique of the subcutaneous implantable cardioverter-defibrillator (S-ICD) was introduced as an alternative to the standard three-incision approach by omitting the superior parasternal incision. Thereby, complications may be prevented. Short-term follow-up demonstrated the safety and efficacy of the two-incision technique. However, long-term results are lacking. Methods: This retrospective study included patients implanted between February 2009 and June 2020. Patients were divided into a group of patients who were implanted with the standard three-incision technique and a group who were implanted with the two-incision technique. Outcomes were defibrillation impedance and efficacy and complications requiring intervention. Results: A total of 268 patients were included (age 42.4 ± 16.6 years, 35.4% female, BMI 25.1 ± 4.5 kg/m 2). Thirty-one patients underwent S-ICD implantation with the three-incision technique and 237 patients with the two-incision technique. First shock efficacy during defibrillation testing was 93% in the three-incision group versus 94% in the two-incision group (P = .69), and shock impedance was 85 versus 68 ohms (P = .04). First shock success was 75% versus 76% for spontaneous episodes (P = 1.00). Complication-free survival at 5-year follow-up in the three-incision group was estimated at 0.96 (95% CI 0.90-1.00) versus 0.98 (95% CI 0.96-1.00) in the two-incision group (P = .20) and for inappropriate shocks at 5-year 0.77 (95% CI 0.63-0.94) versus 0.83 (95% CI 0.77-0.89, P = .30), respectively. Conclusion: Five-year follow-up in this S-ICD cohort showed similar complication rates and effectiveness of two-incision technique compared to the three-incision
This is a PDF file of an article that has undergone enhancements after acceptance, such as the addition of a cover page and metadata, and formatting for readability, but it is not yet the definitive version of record. This version will undergo additional copyediting, typesetting and review before it is published in its final form, but we are providing this version to give early visibility of the article. Please note that, during the production process, errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.
Purpose of ReviewClear guidelines on when to select a subcutaneous ICD (S-ICD) over a transvenous ICD (TV-ICD) are lacking. This review will provide an overview of the most recent clinical data on S-ICD and TV-ICD therapy by pooling comparison studies in order to aid clinical decision making.Recent FindingsPooling of observational-matched studies demonstrated an incidence rate ratio (IRR) for device-related complication of 0.90 (95% CI 0.58–1.42) and IRR for lead-related complications of 0.15 (95% CI 0.06–0.39) in favor of S-ICD. The IRR for device infections was 2.00 (95% CI 0.95–4.22) in favor of TV-ICD. Both appropriate shocks (IRR 0.67 (95% CI 0.42–1.06)) and inappropriate shocks (IRR 1.17 (95% CI 0.77–1.79)) did not differ significantly between both groups.SummaryWith randomized data underway, the observational data demonstrate that the S-ICD is associated with reduced lead complications, but this has not yet resulted in a significant reduction in total number of complications compared to TV-ICDs. New technologies are expected to make the S-ICD a more attractive alternative.
Background: The subcutaneous implantable cardioverter-defibrillator (S-ICD) consists of a large generator and is implanted near the left breast. This might lead to discomfort and problems with self-perception and sexuality, especially in the female population. We aimed to assess the issues that female S-ICD patients experience and to provide practical guidance for cardiologists and implanters on minimizing these issues. Methods: For this retrospective single-center study, we conducted semi-structured interviews with four female S-ICD patients and processed their experiences into a questionnaire. This consisted of three open questions and 17 statements that participants could answer through a five-point Likert scale. The questionnaire was subsequently sent to all female adult patients who received an S-ICD between February 2009 and November 2018 in our tertiary centre in Amsterdam, the Netherlands. Results: The response rate of the questionnaire was 73%, with 52 female respondents (mean age 47.4 ± 12.5 years, mean time since implant 4.6 ± 3.1 years). Postoperative pain exceeded the expectation of 54% of the respondents. Furthermore, 14 out of 49 respondents (29%) expressed an unpleasant feeling during intimate contact with their sexual partner since the implant. Many women (44%) reported daily discomfort caused by their bra and preferred a more cranial and posterior position of the S-ICD generator. Finally, a smaller design of the generator is desired by a great majority (63%) of female S-ICD patients Conclusion: Female S-ICD patients experience a variety of issues with a substantial impact on their daily life. Most issues that we identified would benefit from adequate counseling and implanter awareness.
Despite our expanding knowledge about the mechanism underlying atrial fibrillation (AF), the interplay between the biological events underlying AF remains incompletely understood. This study aimed to identify the functionally enriched gene-sets in AF and capture their interconnection via pivotal factors, that may drive or be driven by AF. Global abundance of the proteins in the left atrium of AF patients compared to control patients (n = 3/group), and the functionally enriched biological processes in AF were determined by mass-spectrometry and gene set enrichment analysis, respectively. The data were validated in an independent cohort (n = 19–20/group). In AF, the gene-sets of innate immune system, metabolic process, cellular component disassembly and ion homeostasis were up-regulated, while the gene-set of ciliogenesis was down-regulated. The innate immune system was over-represented by neutrophil degranulation, the components of which were extensively shared by other gene-sets altered in AF. In the independent cohort, an activated form of neutrophils was more present in the left atrium of AF patients with the increased gene expression of neutrophil granules. MYH10, required for ciliogenesis, was decreased in the atrial fibroblasts of AF patients. We report the increased neutrophil degranulation appears to play a pivotal role, and affects multiple biological processes altered in AF.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.