The ever-increasing demand of mobile Internet and multimedia services poses unique and significant challenges for current and future generation wireless networks. These challenges are mainly relating to the support of massive ubiquitous connectivity, low latency and highly efficient utilization of spectrum resources. Therefore, it is vital to consider them extensively prior to design and deployment of future wireless networks. To this end, the present article provides a comprehensive overview of a particularly promising and effective wireless technology, namely, visible light communication (VLC). In this context, we initially provide a thorough overview of frequency domain multiple access techniques for single and multi-carrier systems, which is then followed by an in depth discussion on the technical considerations of optical code division multiple access techniques and their adoption in indoor VLC applications. Furthermore, we address space division multiple access and, finally, we revisit and analyze the distinct characteristics of a new technology, namely, non-orthogonal multiple access, which has been proposed recently as a particularly effective solution.
There is a growing need to develop novel well-characterized biological inks (bioinks) that are customizable for three-dimensional (3D) bioprinting of specific tissue types. Gelatin methacryloyl (GelMA) is one such candidate bioink due to its biocompatibility and tunable mechanical properties. Currently, only low-concentration GelMA hydrogels (≤5% w/v) are suitable as cell-laden bioinks, allowing high cell viability, elongation, and migration. Yet, they offer poor printability. Herein, we optimize GelMA bioinks in terms of concentration and cross-linking time for improved skeletal muscle C2C12 cell spreading in 3D, and we augment these by adding gold nanoparticles (AuNPs) or a two-dimensional (2D) transition metal carbide (MXene nanosheets) for enhanced printability and biological properties. AuNP and MXene addition endowed GelMA with increased conductivity (up to 0.8 ± 0.07 and 0.9 ± 0.12 S/m, respectively, compared to 0.3 ± 0.06 S/m for pure GelMA). Furthermore, it resulted in an improvement of rheological properties and printability, specifically at 10 °C. Improvements in electrical and rheological properties led to enhanced differentiation of encapsulated myoblasts and allowed for printing highly viable (97%) stable constructs. Taken together, these results constitute a significant step toward fabrication of 3D conductive tissue constructs with physiological relevance.
Stress urinary incontinence (SUI), the involuntary urine leakage due to failure of the urethral closure mechanism, is a global health challenge with substantial human suffering and socioeconomic costs. Approximately 167 million male and female patients are predicted to suffer from SUI in 2018, worldwide. A wide range of surgical interventions are available for the treatment of SUI. Severe cases, however, usually require the implantation of artificial urinary sphincter devices. This review comparatively presents and analyzes the working principles, as well as the challenges, associated with the current implantable SUI systems in clinical use. These include slings, urethral bulking agents, artificial urinary sphincters, and adjustable continence devices. It further reports on recent research progress and state-of-the-art in the field of SUI implants, including an original approach proposed by the authors with a pressure feedback sensory mechanism. The new emerging field of artificial muscle devices, including electroactive polymers, provides a promising innovative solution for replacing the weakened urethral sphincter in SUI patients.
An accurate bladder volume monitoring system is a critical component in diagnosis and treatment of urological disorders. Here, we report an implantable bladder volume sensor with a multi-level resistor ladder which estimates the bladder volume through discrete resistance values. Discretization allows the sensor output to be resilient to the long-term drift, hysteresis, and degradation of the sensor materials. Our sensor is composed of biocompatible polypyrrole/agarose hydrogel composite. Because Young's modulus of this composite is comparable to that of the bladder wall, the effect of mechanical loading of the sensor on the bladder movement is minimized which allows more accurate volume monitoring. We also demonstrate the patterning and molding capability of this material by fabrication various structures. Lastly, we successfully demonstrate the functionality of the multi-level resistor ladder sensor as a bladder volume sensor by attaching the sensor on the pig's bladder and observing the impedance change of the sensor.
Chronic monitoring of bladder activity and urine volume is essential for patients suffering from urinary dysfunctions. However, due to the anatomy and dynamics of the bladder, chronic and precise monitoring of bladder activity remains a challenge. Here, we propose a new sensing mechanism that measures the bladder volume using a resistive ladder network with contact switches. Instead of measuring the impedance between the electrode continuously, the proposed sensor provides a digitized output (‘on’ or ‘off’) when the bladder volume reaches a certain threshold value. We present simple proof-of-concept sensors which compare the discrete-mode operation to the continuous-mode operation. In addition, by using multiple pairs of this contact-mode switch in a resistor ladder structure, we demonstrate monitoring of the bladder volume in four discrete steps using an idealized balloon and an ex vivo pig’s bladder. We implemented the resistive ladder network using a conductive polypyrrole/agarose hydrogel composite which exhibits a Young’s modulus comparable to that of the bladder wall. Compared to the continuous-mode operation, the proposed sensing mechanism is less susceptible to drift due to material degradation and environmental factors.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.