Purpose To evaluate safety, human radiation dosimetry and optimal imaging time of [89Zr]trastuzumab in patients with HER2-positive breast cancer. Procedures Twelve women with HER2-positive breast cancer underwent [89Zr]trastuzumab-PET/CT twice within 7 days postinjection. Biodistribution data from whole-torso PET/CT images, and organ time-activity curves were created using data from all patients. Human dosimetry was calculated using OLINDA with the adult female model. Results High-quality images and the greatest tumor-to-nontumor contrast were achieved with images performed 5 ± 1 day postinjection. Increased [89Zr]trastuzumab uptake was seen in at least one known lesion in 10 patients. The liver was the dose-limiting organ (retention of ~12% of the injected dose and average dose of 1.54 mSv/MBq. The effective dose was 0.47 mSv/MBq. No adverse effects of [89Zr]trastuzumab were encountered. Conclusion [89Zr]trastuzumab was safe and optimally imaged at least 4 days post-injection. The liver was the dose-limiting organ.
Complete the test online no later than December 2022. Your online test will be scored immediately. You may make 3 attempts to pass the test and must answer 80% of the questions correctly to receive 1.0 CEH (Continuing Education Hour) credit. SNMMI members will have their CEH credit added to their VOICE transcript automatically; nonmembers will be able to print out a CE certificate upon successfully completing the test. The online test is free to SNMMI members; nonmembers must pay $15.00 by credit card when logging onto the website to take the test. The Health Insurance Portability and Accountability Act (HIPAA) of 1996 has made an impact on the operation of health-care organizations. HIPAA includes 5 titles, and its regulations are complex. Many are familiar with the HIPAA aspects that address protection of the privacy and security of patients' medical records. There are new rules to HIPAA that address the implementation of electronic medical records. HIPAA provides rules for protected health information (PHI) and what should be protected and secured. The privacy rule regulates the use and disclosure of PHI and sets standards that an entity working with health data must follow to protect patients' private medical information. The HIPAA security rule complements the privacy rule and requires entities to implement physical, technical, and administrative safeguards to protect the privacy of PHI. This article-part 1 of a 2-part series-is a refresher on HIPAA, its history, its rules, its implications, and the role that imaging professionals play.
A novel quality control and quality assurance device provides time-activity curves that can identify and characterize PET/CT radiotracer infiltration at the injection site during the uptake phase. The purpose of this study was to compare rates of infiltration detected by the device with rates detected by physicians. We also assessed the value of using the device to improve injection results in our center. 109 subjects consented to the study. All had passive device sensors applied to their skin near the injection site and mirrored on the contralateral arm during the entire uptake period. Nuclear medicine physicians reviewed standard images for the presence of dose infiltration. Sensor-generated time-activity curves were independently examined and then compared with the physician reports. Injection data captured by the software were analyzed, and the results were provided to the technologists. Improvement measures were implemented, and rates were remeasured. Physician review of the initial 40 head-to-toe field-of-view images identified 15 cases (38%) of dose infiltration (9 minor, 5 moderate, and 1 significant). Sensor time-activity curves on these 40 cases independently identified 22 cases (55%) of dose infiltration (16 minor, 5 moderate, and 1 significant). After the time-activity curve results and the contributing factor analysis were shared with technologists, injection techniques were modified and an additional 69 cases were studied. Of these, physician review identified 17 cases (25%) of infiltration (13 minor, 3 moderate, and 1 significant), a 34% decline. Sensor time-activity curves identified 4 cases (6%) of infiltration (2 minor and 2 moderate), an 89% decline. The device provides valuable quality control information for each subject. Time-activity curves can further characterize visible infiltration. Even when the injection site was out of the field of view, the time-activity curves could still detect and characterize infiltration. Our initial experience showed that the quality assurance information obtained from the device helped reduce the rate and severity of infiltration. The device revealed site-specific contributing factors that helped nuclear medicine physicians and technologists customize their quality improvement efforts to these site-specific issues. Reducing infiltration can improve image quality and SUV quantification, as well as the ability to minimize variability in a site's PET/CT results.
Background: Infiltrations of 18F-fluorodeoxyglucose (FDG) injections affect positron emission tomography/computed tomography (PET/CT) image quality and quantification. A device using scintillation sensors (Lucerno Dynamics, Cary, NC) provides dynamic measurements acquired during FDG uptake to identify and characterize radioactivity near the injection site prior to patient imaging. Our aim was to compare sensor measurements against dynamic PET image acquisition, our proposed reference in assessing injection quality during the uptake period.Methods: Subjects undergoing routine FDG PET/CT imaging were eligible for this Institutional Review Board approved prospective study. After providing informed consent, subjects had sensors topically placed on their arms. FDG was injected into subjects' veins directly on the PET imaging table. Dynamic images of the injection site were acquired during 45 min of the uptake period. These dynamic image acquisitions and subjects' routine standard static images were evaluated by nuclear medicine physicians for abnormal FDG accumulation near the injection site. Sensor measurements were interpreted independently by Lucerno staff. Dynamic image acquisition interpretation results were compared to the sensor measurement interpretations and to static image interpretations.Results: Twenty-four subjects were consented and enrolled. Data from 21 subjects were gathered. During dynamic image acquisition review, physicians interpreted 4 subjects with no FDG accumulation at the injection site, whereas 17 showed evidence of accumulation. In 10 of the 17 cases that showed FDG accumulation, the FDG presence at the injection site resolved completely during uptake corresponding to venous stasis, the temporary sequestration of blood from circulation. Static image interpretation agreed with dynamic images interpretation in 11/21 (52%) subjects. Sensor measurement interpretations agreed with the dynamic images interpretations in 18/21 (86%) subjects.Conclusions: Sensor measurements can be an effective way to identify and characterize infiltrations and venous stasis. Comparable to an infiltration, venous stasis may produce spurious and clinically meaningful measurement bias and possibly even scan misinterpretation. Since the quality and quantification of PET/CT studies are of clinical importance, sensor measurements acquired during the FDG uptake may prove to be a useful quality control measure to reduce infiltration rates and potentially improve patient care.Registration: Clinicaltrials.gov, Identifier: NCT03041090
Purpose:PGN650 is a F(ab′)2 antibody fragment that targets phosphatidylserine (PS), a marker normally absent that becomes exposed on tumor cells and tumor vasculature in response to oxidative stress and increases in response to therapy. PGN650 was labeled with 124I to create a positron emission tomography (PET) agent as an in vivo biomarker for tumor microenvironment and response to therapy. In this phase 0 study, we evaluated the pharmacokinetics, safety, radiation dosimetry, and tumor targeting of this tracer in a cohort of patients with cancer.Methods:Eleven patients with known solid tumors received approximately 140 MBq (3.8 mCi) 124I-PGN650 intravenously and underwent positron emission tomography–computed tomography (PET/CT) approximately 1 hour, 3 hours, and either 24 hours or 48 hours later to establish tracer kinetics for the purpose of calculating radiation dosimetry (from integration of the organ time-activity curves and OLINDA/EXM using the adult male and female models).Results:Known tumor foci demonstrated mildly increased uptake, with the highest activity at the latest imaging time. There were no unexpected adverse events. The liver was the organ receiving the highest radiation dose (0.77 mGy/MBq); the effective dose was 0.41 mSv/MBq.Conclusion:Although 124I-PGN650 is safe for human PET imaging, the tumor targeting with this agent in patients was less than previously observed in animal studies.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.