For the treatment of concomitant LHBT lesions in patients with rotator cuff tears, both a funnel tenotomy and an intracuff tenodesis showed good clinical outcomes. Even though the incidence of Popeye deformity in the funnel tenotomy group tended to be higher, there was no significant difference in the overall incidence of cosmetic deformity between the 2 groups.
BackgroundThere has been no report to date regarding retraction patterns of delaminated rotator cuff tears. The purpose of this study was to evaluate the incidence and tearing patterns of delamination and repair integrity after the dual-layer repair of delaminated cuff tears.Methods/designA consecutive series of 64 patients with posterosuperior rotator cuff tears underwent arthroscopic rotator cuff repair from August 2011 to September 2012. Among the patients, 53 who received either dual-layer double-row (DLDR) repair or dual-layer suture bridge (DLSB) repair and 11 who received a single-layer repair were evaluated. The mean follow-up period after surgery was 26.5 months. The retraction direction of the deep and superficial layers was analyzed, and the integrity of the repaired constructs was determined in 37 patients through magnetic resonance imaging at a mean of 12.1 months after surgery.ResultsThe incidence of delamination was 82.8 %. Posteromedial retraction of the deep and superficial layers was observed in 98.1 and 88.5 % of cases, respectively. The Constant score and UCLA score increased preoperatively to postoperatively, showing no significant differences between the dual-layer repair group and single-layer repair group. Retear was found in two (7.6 %) patients in the dual-layer repair group and three (27.2 %) patients in the single-layer repair group (p = 0.016).ConclusionsDifferential rotator cuff repair strategies are needed to address rotator cuff tears, since recent studies have changed our concept of rotator cuff tears. We have focused on three areas: incidence, retraction patterns, and clinical outcomes. The incidence of delamination was extremely high. Both the superficial layer and deep layer were mainly retracted posteromedially. The retraction of the deep layer and superficial layer may be affected by the infraspinatus. Dual-layer rotator cuff repair based on the retraction pattern of delamination is recommended for improvement of repair integrity and of clinical outcomes.
[Purpose] This study aimed to elucidate the effects of a novel walking training program
with postural correction and visual feedback on walking function in patients with
post-stroke hemiparesis. [Subjects] Sixteen subjects were randomly allocated to either the
experimental group (EG) or the control group (CG), with eight subjects in each. [Methods]
EG and CG subjects performed a 30-min treadmill walking training exercise twice daily for
2 weeks. EG subjects also underwent postural correction using elastic bands and received
visual feedback during walking. The 10-m walk test was performed, and gait parameters were
measured using a gait analysis system. [Results] All parameters showed significant main
effects for the group factor and time-by-group interactions. Significant main effects for
the time factor were found in the stride length and stance phase ratios. [Conclusion] The
novel walking training program with postural correction and visual feedback may improve
walking function in patients with post-stroke hemiparesis.
Between open and arthroscopic repair for severely retracted, large to massive rotator cuff tears, there was no significant difference in detachment of the deltoid origin and alterations of the deltoid muscle after repair. Postoperative alterations of the deltoid occurred in arthroscopic surgery as well as in open surgery. For immobile massive rotator cuff tear, open repair is an acceptable technique as long as the deltoid muscle is meticulously reattached after surgery.
Background: Indirect reduction technique offers a valid option in the treatment of proximal humerus fracture. The purpose of this study is to evaluate the functional outcome and the complication rate after indirect reduction and internal fixation of unstable proximal humeral fractures with use of a locking plate. Methods: Twenty four patients with acute proximal humerus fracture were managed with indirect reduction and internal fixation with a locking plate. The mean follow-up period was 15.5 months.
Results:The anatomical reduction of the medial cortex buttress was seen in 16 patients (66%) of the Group A and the non-anatomical reduction was seen in 8 patients (33%) of the Group B. Mean union time was 3.2 ± 1.9 months; it was 2.2 ± 0.6 months in the Group A and 5.3 ± 2.2 months in the Group B (p < 0.05). In our series, there were 6 cases of complications and these include 2 cases of varus malunion, 2 cases of shoulder stiffness, 1 case of heterotrophic ossification, 2 cases of screw perforation and 1 case of impingement. Conclusions: We conclude from our studies that indirect reduction and internal fixation using locking plate for acute proximal humerus fracture can give good results with bony union and predictable good overall functional outcome. If the medial cortex buttress is well maintained, a better anatomical reduction would be achieved, the union would be prompted, the pain would be further reduced and the range of the motion would be recovered more promptly. (Clin Shoulder Elb 2014;17(1):2-9)
Isolated acromial fracture is not common and it frequently accompanies fractures to the coracoid process and glenoid bone and also injuries to the acromioclavicular joint. Furthermore, most of these combined acromial fractures have minimal displacement, which needs no additional treatment other than protection for a certain period of time. We have experienced a case of isolated fracture of the posterolateral angle of the acromion, which we reduced and fixated using K-wire and cannulated screws. We report on the technical aspects and clinical results of this reduction and fixation, along with a review of the literature.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.