Patients and MethodsThis study was approved by Ann & Robert H. Lurie Children's Hospital of Chicago Institutional Review Board. The requirement of obtaining informed consent was waived. Between 2002 and 2017, 10 patients with a double aortic arch underwent vascular ring repair that included KD excision. During that same period, 66 patients with a double aortic arch underwent operative repair. Of those 66 patients, 82% had a right dominant double aortic arch. These patients' medical records were retrospectively reviewed to collect medical history, presenting symptoms, perioperative imaging, operative procedure descriptions, and postoperative
The ultimate strength of blade stiffened composite plates with various sizes of the stiffener is studied numerically using ANSYS software. The GFRP stiffened composite plates were modeled in ANSYS as SHELL elements with orthotropic properties. The finite element model of the GFRP stiffened composite plates was analysed to obtain deflection, axial deformation and stress contours and the ultimate load values. The obtained results of the finite element model were validated with that of available experimental data. The validated finite element model was used to study the effect of stiffener size. The stiffener size was varied from 10mm to 100mm. It was observed that smaller size of stiffeners were ineffective in stiffening the plate. The optimum size of stiffener was found to be 50mm to 75 mm. .
Background: A 49-year-old male presented with a delayed diagnosis of infective endocarditis leading to extensive intracardiac destruction. Such cases present technical challenges to operative debridement as crucial anchoring points for replacement conduits are compromised.
Case Presentation: Our patient presented at age 49 with nausea, lethargy, and diarrhea 2 weeks after recent travel. His prior history included bioprosthetic valve replacement for a bicuspid aortic valve. The patient was first given a trial of antimicrobials for a suspected UTI. Subsequently, he was admitted briefly to an outside hospital for a “cardiac work-up,” which returned negative. The patient sought care for the third time, during which he developed unstable supraventricular tachycardia, prompting echocardiography 16 days following the onset of symptoms. Echocardiography demonstrated a 6 cm abscess cavity invading the interventricular septum with a fistula into the left ventricular outflow tract, multiple ventricular septal defects (VSD), and suspected fistulae into the right ventricular outflow tract. The patient was treated with valve explant and extensive debridement. A valved-conduit for the aorta could not be sewn to the aortic annulus in the usual fashion due to destruction and debridement of the annulus, so a neo-annulus was created using the anterior leaflet of the mitral valve and the left ventricular outflow tract of the heart below the level of the VSDs. A mechanical-valved conduit was implanted onto the neo-annulus. A pacemaker was subsequently implanted.
Conclusion: In patients with extensive intracardiac destruction with the compromise of the aortic annulus due to infective endocarditis, a low-seated, mechanical-valved conduit implanted directly to the aorto-mitral curtain and left ventricular outflow tract should be considered a novel, durable reconstructive option that allows complete debridement of infected tissues.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.