Background-Percutaneous aortic valve implantation by an antegrade transvenous approach has been described but is problematic. Retrograde prosthetic aortic valve implantation via the femoral artery has potential advantages. Percutaneous prosthetic aortic valve implantation via the femoral arterial approach is described and the initial experience reported. Methods and Results-The valve prosthesis is constructed from a stainless steel stent with an attached trileaflet equine pericardial valve and a fabric cuff. After routine aortic balloon valvuloplasty, a 22F or 24F sheath is advanced from the femoral artery to the aorta. A steerable, deflectable catheter facilitates manipulation of the prosthesis around the aortic arch and through the stenotic valve. Rapid ventricular pacing is used to reduce cardiac output while the delivery balloon is inflated to deploy the prosthesis within the annulus. Percutaneous aortic prosthetic valve implantation was attempted in 18 patients (aged 81Ϯ6 years) in whom surgical risk was deemed excessive because of comorbidities. Iliac arterial injury, seen in the first 2 patients, did not recur after improvement in screening and access site management. Implantation was successful in 14 patients. After successful implantation, the aortic valve area increased from 0.6Ϯ0.
ObjectivesThe aim of this study was: 1) to evaluate the acute and late outcomes of a transcatheter aortic valve implantation (TAVI) program including both the transfemoral (TF) and transapical (TA) approaches; and 2) to determine the results of TAVI in patients deemed inoperable because of either porcelain aorta or frailty.
Background-The majority of prosthetic heart valves currently implanted are tissue valves that can be expected to degenerate with time and eventually fail. Repeat cardiac surgery to replace these valves is associated with significant morbidity and mortality. Transcatheter heart valve implantation within a failed bioprosthesis, a "valve-in-valve" procedure, may offer a less invasive alternative. Methods and Results-Valve-in-valve implantations were performed in 24 high-risk patients. Failed valves were aortic (nϭ10), mitral (nϭ7), pulmonary (nϭ6), or tricuspid (nϭ1) bioprostheses. Implantation was successful with immediate restoration of satisfactory valve function in all but 1 patient. No patient had more than mild regurgitation after implantation. No patients died during the procedure. Thirty-day mortality was 4.2%. Mortality was related primarily to learning-curve issues early in this high-risk experience. At baseline, 88% of patients were in New York Heart Association functional class III or IV; at the last follow-up, 88% of patients were in class I or II. At a median follow-up of 135 days (interquartile range, 46 to 254 days) and a maximum follow-up of 1045 days, 91.7% of patients remained alive with satisfactory valve function. Conclusions-Transcatheter valve-in-valve implantation is a reproducible option for the management of bioprosthetic valve failure. Aortic, pulmonary, mitral, and tricuspid tissue valves were amenable to this approach. This finding may have important implications with regard to valve replacement in high-risk patients.
Background-Aortic valve replacement with cardiopulmonary bypass is currently the treatment of choice for symptomatic aortic stenosis but carries a significant risk of morbidity and mortality, particularly in patients with comorbidities. Recently, percutaneous transfemoral aortic valve implantation has been proposed as a viable alternative in selected patients. We describe our experience with a new, minimally invasive, catheter-based approach to aortic valve implantation via left ventricular apical puncture without cardiopulmonary bypass or sternotomy. Methods and Results-A left anterolateral intercostal incision is used to expose the left ventricular apex. Direct needle puncture of the apex allows introduction of a hemostatic sheath into the left ventricle. The valve prosthesis, constructed from a stainless steel stent with an attached trileaflet equine pericardial valve, is crimped onto a valvuloplasty balloon. The prosthetic valve and balloon catheter are passed over a wire into the left ventricle. Positioning within the aortic annulus is confirmed by fluoroscopy, aortography, and echocardiography. Rapid ventricular pacing is used to reduce cardiac output while the balloon is inflated, deploying the prosthesis within the annulus. Transapical aortic valve implantation was successfully performed in 7 patients in whom surgical risk was deemed excessive because of comorbidities. Echocardiographic median aortic valve area increased from 0.7Ϯ0.1 cm 2 (interquartile range) to 1.8Ϯ0.8 cm 2 (interquartile range). There were no intraprocedural deaths. At a follow up of 87Ϯ56 days, 6 of 7 patients remain alive and well.
Conclusions-This
Background-Transcatheter aortic valve implantation is an alternative to open heart surgery in patients with aortic stenosis. However, long-term data on a programmatic approach to aortic valve implantation remain sparse. Methods and Results-Transcatheter aortic valve implantation was performed in 168 patients (median age, 84 years) in the setting of severe aortic stenosis and high surgical risk. Access was transarterial (nϭ113) or, in the presence of small iliofemoral artery diameter, transapical (nϭ55). The overall success rate was 94.1% in this early experience. Intraprocedural mortality was 1.2%. Operative (30-day) mortality was 11.3%, lower in the transarterial group than the transapical group (8.0% versus 18.2%; Pϭ0.07). Overall mortality fell from 14.3% in the initial half to 8.3% in the second half of the experience, from 12.3% to 3.6% (Pϭ0.16) in transarterial patients and from 25% to 11.1% (Pϭ0.30) in transapical patients. Functional class improved over the 1-year postprocedure period (PϽ0.001). Survival at 1 year was 74%. The bulk of late readmission and mortality was not procedure or valve related but rather was due to comorbidities. Paravalvular regurgitation was common but generally mild and remained stable at late follow-up. At a maximum of Ͼ3 years and a median of 221 days, structural valve failure was not observed.
Conclusions-Transcatheter
Aortic valve implantation can successfully be performed via a minimally invasive apical approach without the need for cardiopulmonary bypass. The early results in this initial series are encouraging. This initial experience suggests that the minimally invasive transapical approach is a viable alternative for patients in whom open-heart surgery is not feasible or poses unacceptable risks.
The incidence of CeV events is highest within 24 h of TAVI, but this risk may remain elevated for up to 2 months. A prior history of cerebrovascular disease is an independent predictor. This may have implications for patient selection and antithrombotic strategies.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.