Background: Total ankle arthroplasty is an alternative for arthrodesis. The objective of this study was to investigate the safety of trabecular-metal ankle prosthetic system with transfibular approach and external frame and its association with changes in clinical and functional scores. Methods: Between May 2013 and June 2017, a total of 104 consecutive patients underwent primary total ankle arthroplasty with a trabecular metal implant. The prospective clinical and radiographic data were collected. The mean follow-up time was 43.6 (14.6) months. Results: Of 104 patients, 88 (89%) reported improved functioning and 65 (66%) were very satisfied with the surgery. Of the patients, 51 (50%) did not report any pain at the end of follow-up at all. The average Kofoed score was 37.6 (SD 17.4) points at baseline and 74.8 (SD 20.6) points at the end of follow-up. There were 37 additional procedures, and the complication rate was nearly 20%. Conclusion: Trabecular-metal total ankle prosthesis showed promising clinical results concerning pain and function. At 5-year follow-up, osteolysis and component loosening were rare. Level of Evidence: Level IV, case series.
Background: Peri-implant osteolysis is one of the major complications related to total ankle replacement. The aim of this study was to investigate the short- to midterm incidence of peri-implant osteolysis using computed tomography (CT) as imaging method for the Trabecular Metal Total Ankle (TMTA) implant representing a novel total ankle replacement (TAR) implant design regarding material and surgical technique. Methods: In total, 104 consecutive patients who had a primary TMTA replacement between March 2013 and October 2017 were included in the study. The radiographic evaluation included weightbearing anteroposterior and lateral views at baseline and after 3, 6, and every 12 months postoperatively. A helical CT was undertaken preoperatively and of the 80 patients available to follow up at least 12 months postoperatively, with average time interval between the TAR operation and the latest CT of 39 (range, 12-85) months. Results: Eight of 80 patients had altogether 11 osteolytic lesions around the components on CT images. Seven lesions were found in tibia, 3 in talus, and 1 in distal fibula. Four of the tibial lesions were situated in the medial malleolus and were not in contact with the prosthesis component. The sizes of the osteolytic lesions ranged between 7 and 20 mm, and the average volume of the lesions was 689 mm3. Conclusion: We conclude that the risk of peri-implant osteolysis with the TMTA implant is minimal in short to midterm. The anatomic configuration, unique material, and surgical technique may all contribute to the TMTA implant having a low rate of peri-implant osteolysis. Level of Evidence: Level IV, case series.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.