Selective serotonin reuptake inhibitors (SSRIs), the most widely used drugs for the treatment of depression, have been reported to reduce bone formation and increase the risk of bone fracture. Since osseointegration is influenced by bone metabolism, this study aimed to investigate the association between SSRIs and the risk of failures in osseointegrated implants. This retrospective cohort study was conducted on patients treated with dental implants from January 2007 to January 2013. A total of 916 dental implants in 490 patients (94 implants on 51 patients using SSRIs) were used to estimate the risk of failure associated with the use of SSRIs. Data analysis involved Cox proportional hazards, generalized estimating equation models, multilevel mixed effects parametric survival analysis, and Kaplan-Meier analysis. After 3 to 67 mo of follow-up, 38 dental implants failed and 784 succeeded in the nonusers group, while 10 failed and 84 succeeded in the SSRI-users group. The main limitation of this retrospective study was that drug compliance dose and treatment period could not be acquired from the files of the patients. The primary outcome was that compared with nonusers of SSRIs, SSRI usage was associated with an increased risk of dental implants failure (hazard ratio, 6.28; 95% confidence interval, 1.25-31.61; p = .03). The failure rates were 4.6% for SSRI nonusers and 10.6% for SSRI users. The secondary outcomes were that small implant diameters (≤4 mm; p = .02) and smoking habits (p = .01) also seemed to be associated with higher risk of implant failure. Our findings indicate that treatment with SSRIs is associated with an increased failure risk of osseointegrated implants, which might suggest a careful surgical treatment planning for SSRI users.
This study assessed the effect of simulated mastication on the retention of two stud attachment systems for 2-implants overdentures. Sixteen specimens, each simulating an edentulous ridge with implants and an overdenture were divided into two groups, according to the attachment system: Group I (Nobel Biocare ball-socket attachments) and Group II (Locator attachments). Retention forces were measured before and after 400,000 simulated masticatory loads in a customised device. Data were compared by two-way anova followed by Bonferroni test (α = 0·05). Group I presented significantly lower retention forces (Newtons) than Group II at baseline (10·6 ± 3·6 and 66·4 ± 16·0, respectively). However, differences were not significant after 400,000 loads (7·9 ± 4·3 and 21·6 ± 17·0). The number of cycles did not influence the measurements in Group I, whereas a non-linear descending curve was found for Group II. It was concluded that simulated mastication resulted in minor changes for the ball attachment tested. Nevertheless, it reduced the retention of Locator attachments to 40% of the baseline values, what suggests that mastication is a major factor associated with maintenance needs for this system.
The aim of this study was to validate an original portable device to measure attachment retention of implant overdentures both in the lab and in clinical settings. The device was built with a digital force measurement gauge (Imada) secured to a vertical wheel stand associated with a customized support to hold and position the denture in adjustable angulations. Sixteen matrix and patrix cylindrical stud attachments (Locator) were randomly assigned as in vitro test specimens. Attachment abutments were secured in an implant analogue hung to the digital force gauge or to the load cell of a traction machine used as the gold standard (Instron Universal Testing Machine). Matrices were secured in a denture duplicate attached to the customized support, permitting reproducibility of their position on both pulling devices. Attachment retention in the axial direction was evaluated by measuring maximum dislodging force or peak load during five consecutive linear dislodgments of each attachment on both devices. After a wear simulation, retention was measured again at several time periods. The peak load measurements with the customized Imada device were similar to those obtained with the gold standard Instron machine. These findings suggest that the proposed portable device can provide accurate information on the retentive properties of attachment systems for removable dental prostheses.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.