BackgroundSoluble LH/hCG receptor (sLHCGR) released from placental explants and transfected cells can be detected in sera from pregnant women. To determine whether sLHCGR has diagnostic potential, quantitative ELISAs were developed and tested to examine the correlation between pregnancy outcome and levels of serum sLHCGR and hCG-sLHCGR complex.MethodsAnti-LHCGR poly- and monoclonal antibodies recognizing defined LHCGR epitopes, commerical anti-hCGbeta antibody, together with recombinant LHCGR and yoked hCGbeta-LHCGR standard calibrators were used to develop two ELISAs. These assays were employed to quantify serum sLHCGR and hCG-sLHCGR at first trimester human pregnancy.ResultsTwo ELISAs were developed and validated. Unlike any known biomarker, sLHCGR and hCG-sLHCGR are unique because Down’s syndrome (DS), preeclampsia and preterm delivery are linked to both low (less than or equal to 5 pmol/mL), and high (equal to or greater than 170 pmol/mL) concentrations. At these cut-off values, serum hCG-sLHCGR together with PAPP-A detected additional DS pregnancies (21%) which were negative by free hCGbeta plus PAPP-A screening procedure. Therefore, sLHCGR/hCG-sLHCGR has an additive effect on the current primary biochemical screening of aneuploid pregnancies. More than 88% of pregnancies destined to end in fetal demise (stillbirth) exhibited very low serum hCG-sLHCGR(less than or equal to 5 pmol/mL) compared to controls (median 16.15 pmol/mL, n = 390). The frequency of high hCG-sLHCGR concentrations (equal to or greater than 170 pmol/mL) in pathological pregnancies was at least 3-6-fold higher than that of the control, suggesting possible modulation of the thyrotropic effect of hCG by sLHCGR.ConclusionsSerum sLHCGR/hCG-sLHCGR together with PAPP-A, have significant potential as first trimester screening markers for predicting pathological outcomes in pregnancy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.