BackgroundHelicobacter pylori is an important global pathogen infecting approximately 50% of the world’s population. This study was undertaken in order to estimate the prevalence rate of Helicobacter pylori infections among adults living in Turkey and to investigate the associated risk factors.MethodThis study was a nationally representative cross sectional survey, using weighted multistage stratified cluster sampling. All individuals aged ≥18 years in the selected households were invited to participate in the survey. Ninety two percent (n = 2382) of the households in 55 cities participated; 4622 individuals from these households were tested with the 13C-Urea breath test. Helicobacter pylori prevalence and associated factors were analysed by the t test, chi square and multiple logistic regression with SPSS11.0.ResultsThe weighted overall prevalence was 82.5% (95% CI: 81.0-84.2) and was higher in men. It was lowest in the South which has the major fruit growing areas of the country. The factors included in the final model were sex, age, education, marital status, type of insurance (social security), residential region, alcohol use, smoking, drinking water source. While education was the only significant factor for women, residential region, housing tenure, smoking and alcohol use were significant for men in models by sex.ConclusionIn Turkey, Helicobacter pylori prevalence was found to be very high. Individuals who were women, elderly adults, single, had a high educational level, were living in the fruit growing region, had social security from Emekli Sandigi, were drinking bottled water, non smokers and regular alcohol consumers, were under less risk of Helicobacter pylori infection than others.
OBJECTIVE To determine the typical microbial bioburden (overall bacterial and multidrug-resistant organisms [MDROs]) on high-touch healthcare environmental surfaces after routine or terminal cleaning. DESIGN Prospective 2.5-year microbiological survey of large surface areas (>1,000 cm2). SETTING MDRO contact-precaution rooms from 9 acute-care hospitals and 2 long-term care facilities in 4 states. PARTICIPANTS Samples from 166 rooms (113 routine cleaned and 53 terminal cleaned rooms). METHODS Using a standard sponge-wipe sampling protocol, 2 composite samples were collected from each room; a third sample was collected from each Clostridium difficile room. Composite 1 included the TV remote, telephone, call button, and bed rails. Composite 2 included the room door handle, IV pole, and overbed table. Composite 3 included toileting surfaces. Total bacteria and MDROs (ie, methicillin-resistant Staphylococcus aureus, vancomycin-resistant enterococci [VRE], Acinetobacter baumannii, Klebsiella pneumoniae, and C. difficile) were quantified, confirmed, and tested for drug resistance. RESULTS The mean microbial bioburden and range from routine cleaned room composites were higher (2,700 colony-forming units [CFU]/100 cm2; ≤1-130,000 CFU/100 cm2) than from terminal cleaned room composites (353 CFU/100 cm2; ≤1-4,300 CFU/100 cm2). MDROs were recovered from 34% of routine cleaned room composites (range ≤1-13,000 CFU/100 cm2) and 17% of terminal cleaned room composites (≤1-524 CFU/100 cm2). MDROs were recovered from 40% of rooms; VRE was the most common (19%). CONCLUSIONS This multicenter bioburden summary provides a first step to determining microbial bioburden on healthcare surfaces, which may help provide a basis for developing standards to evaluate cleaning and disinfection as well as a framework for studies using an evidentiary hierarchy for environmental infection control. Infect Control Hosp Epidemiol 2016;1426-1432.
Ventilation standards, health, and indoor air quality have not been adequately examined for residential weatherization. This randomized trial showed how ASHRAE 62-1989 (n=39 houses) and ASHRAE 62.2-2010 (n=42 houses) influenced ventilation rates, moisture balance, indoor air quality, and self-reported physical and mental health outcomes. Average total airflow was nearly twice as high for ASHRAE 62.2-2010 (79 vs. 39 cfm). Volatile organic compounds, formaldehyde and carbon dioxide were all significantly reduced for the newer standard and first-floor radon was marginally lower, but for the older standard, only formaldehyde significantly decreased. Humidity in the ASHRAE 62.2-2010 group was only about half that of the ASHRAE 62-1989 group using the moisture balance metric. Radon was higher in the basement but lower on the first floor for ASHRAE 62.2-2010. Children in each group had fewer headaches, eczema, and skin allergies after weatherization and adults had improvements in psychological distress. Indoor air quality and health improve when weatherization is accompanied by an ASHRAE residential ventilation standard, and the 2010 ASHRAE standard has greater improvements in certain outcomes compared to the 1989 standard. Weatherization, home repair, and energy conservation projects should use the newer ASHRAE standard to improve indoor air quality and health.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.