In order to optimize the accuracy of imaging in Gamma Knife radiosurgery using the image fusion options available in the Leksell gamma plan. Phantom images from 1.5 Tesla MRI Scan (Magnetom vision -Siemens) and Computed Tomography images from Philips Brilliance 16 CT scanner were used for image fusion in Gammaplan treatment planning system . The images were fused using co-registration technique using multiview and imagemerge modules. Stereotactic coordinates were then calculated for known targets. Vector distances from the centre of the Leksell coordinate system to five known targets were measured in CT, MR and CT-MR fused images and compared with geometrical measurements. The mean values of maximum absolute errors were 0.34 mm ,0.41 mm.0.38 mm (along x-axis), 0.43 mm, 1.53 mm, 0.62 mm (along y-axis) and 0.75 mm 2.02 mm, 0.93 mm (along z-axis) for CT ,MR and CT-MR fused image data respectively.The mean error in calculating the vector distances from the center of the Leksell coordinate system (100, 100, 100) to the known target volumes are 0.22 mm, 0.8 mm and 0.43 mm for CT, MR and CT-MR fused images, respectively. Image fusion functions available in gamma plan are useful for combining the features of CT and MR imaging modalities. These methods are highly useful in clinical situations where the error associated with Magnetic Resonance Imaging is beyond acceptable levels.
Abstract. With the increase in design complexity, verification times are growing significantly. Reuse of verification environment is an important means of reducing the verification effort. This paper address the problem of developing a reusable and a scalable verification environment for memory controllers. Though the architecture of different memory controllers varies significantly, they share a common transactional property. This property is exploited to develop a reusable verification environment. The proposed transactional verification environment coupled with the assertion based latency checkers achieve near cycle-accurate efficiency. The proposed verification environment is also scalable to verify memory controllers with multiple ports. We applied the above approach for the verification of three memory controllers, and results showed significant improvement in productivity and effectiveness.
Dosimetrical evaluation of Leksell Gamma Knife 4C radiosurgery unit A number of experiments was performed using standard protocols, in order to evaluate the dosimetric accuracy of Leksell Gamma Knife 4C unit. Verification of the beam alignment has been performed for all collimators using solid plastic head phantom and Gafchromic™ type MD-55 films. The study showed a good agreement of Leksell Gammaplan calculated dose profiles with experimentally determined profiles in all three axes. Isocentric accuracy is verified using a specially machined cylindrical aluminium film holder tool made with very narrow geometric tolerances aligned between trunnions of 4 mm collimator. Considering all uncertainties in all three dimensions, the estimated accuracy of the unit was 0.1 mm. Dose rate at the centre point of the unit has been determined according to the IAEA, TRS-398 protocol, using Unidose-E (PTW-Freiburg, Germany) with a 0.125 cc ion chamber, over a period of 6 years. The study showed that the Leksell Gamma Knife 4C unit is excellent radiosurgical equipment with high accuracy and precision, which makes it possible to deliver larger doses of radiation, within the limits defined by national and international guidelines, applicable for stereotactic radiosurgery procedures.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.