A sorption thermal energy storage (TES) device for domestic heating is presented in this article. The TES device adopts the new design scenario with valve-less adsorber and separate reservoir to eliminate the largediameter vacuum valve for vapor flow, which decreases the cost, reduces the vapor flow resistance, and improves the system reliability. The device is charged by the electric heater, which can add much flexibility to the building energy system as well as contribute to the valley filling and peak shaving from demand side management. The newly developed composite sorbent of zeolite 13X/MgSO4/ENG-TSA (expanded natural graphite treated with sulfuric acid) with the salt mass fraction of 15% in the zeolite 13X/MgSO4 mixture is tested and used in the TES device (denoted as XM15/ENG-TSA). Experimental results show that the TES device with XM15/ENG-TSA has the energy storage density of 120.3 kWh•m −3 at 250°C charging temperature and 25-90°C discharging temperature. The temperature lift is as high as 65-69°C with the adsorption and evaporating temperatures of 25°C. The impregnation of MgSO4 dramatically improves the temperature rising rate during the adsorption heat recovery process, but the specific energy storage capacity of XM15/ENG-TSA is similar to that of zeolite 13X/ENG-TSA. The effect of the impregnated MgSO4 suggests that MgSO4 can be used for low-temperature TES to relieve the self-hindrance of the hydration reaction.
The composite sorbents of MgSO4-impregnated zeolite 13X and activated alumina are developed for thermal energy storage (TES) with different temperature ranges. The sorption and desorption characteristics of raw and MgSO4-impregnated activated alumina are studied, and the performances of the selected sorbents are tested in a closed-system TES device. The results are compared with those of raw and MgSO4-impregnated zeolite 13X. It is shown that the impregnated MgSO4 improves the overall TES performances of zeolite 13X and activated alumina. Compared to the raw host matrices, the impregnated MgSO4 remarkably accelerates the temperature-rising rate of zeolite 13X to about three times and improves the temperature lift of activated alumina by 32.5%. The experimental energy storage densities of MgSO4-impregnated zeolite 13X and activated alumina are 123.4 kWh m −3 and 82.6 kWh m −3 , respectively. The sorption temperature region of activated alumina is more aligned with the preferred hydration temperature of MgSO4 in comparison with zeolite 13X. The hydration characteristics of MgSO4 can resolve the solution leakage issue of open systems.Thermodynamic analysis is conducted to evaluate the performances of the TES device with different sorbents.It is found that entransy can be used to assess thermally and electrically driven TES systems reasonably.
Purpose:To investigate the clinical usage of dose verification of Helical Tomotherapy plans by using 2D-array ion chambers, and to develop an efficient way to validate the dose delivered for the patients during treatments.Materials and Methods:A pixel-segmented ionisation chamber device, IMRT MatriXX™ and Multicube™ phantom from IBA were used on ten selected Tomotherapy IMRT/IGRT head and neck plans in this study. The combined phantom was set up to measure the dose distribution from coronal and sagittal planes. The setup of phantom was guided for verifying the correction position by pre-treatment Tomotherapy MVCT images. After the irradiation, the measured dose distributions of coronal and sagittal planes were compared with those from calculation by the planning system for cross verification. The results were evaluated by the absolute and relative doses as well as Gamma (γ) function. The feasibility of the different measuring methods was studied for this rotational treatment technique.Results:The dose distributions measured by the MatriXX 2D array were in good agreements with plans calculated by Tomotherapy planning system. The discrepancy between the measured dose and predicted dose in the selected points was within ±3%. In the comparison of the pixel-segmented ionisation chamber versus treatment planning system using the 3 mm/3% γ-function criteria, the mean passing rates of 2 mm dose grid with γ-parameter ≤1 were 97.37% and 96.91%, in two orthogonal planes (coronal and sagittal directions), respectively.Conclusion:MatriXX with Multicube is a new system created for rotational delivery quality assurance (QA) and found to be reliable to measure both absolute dose and relative dose distributions, simultaneously. It achieves the goal of an efficient and accurate dosimetry validation method of the helical delivery pattern for the Helical Tomotherapy IMRT planning.
Summary
This paper focuses on the novelty pumpless organic Rankine cycle (ORC) and its choice of working fluids. Based on the selection criteria, the refrigerant of R1233zd(E) is firstly chosen and investigated in the pumpless ORC system. In the system, the feed pump is removed, and the refrigerant flows back and forth between two heat exchangers, which act as the evaporator or condenser, respectively. The impacts of the heating water temperature and loads on the system performance are studied to find out the best operating conditions. The low‐grade heat source is simulated by an electric boiler. The temperature of the heat resource ranges from 80°C to 100°C with the interval of 5°C. The temperature of the cooling water inlet is 10°C and is kept constant. The largest average power output is 127 W under the condition of 100°C heating water with nine loads. Because the cycle efficiency with heating steam temperature of 100°C cannot be determined, the highest energy and exergy efficiencies are 3.5% and 17.1%, respectively, for heating water of 95°C with seven loads. The experimental results show that the energy and exergy efficiencies increase with the increase of the heating temperature. The power and current outputs increase when the loads increase under the condition of the constant heating water temperature, whereas the voltage output decreases meanwhile. The generating time increases when the loads increase. This phenomenon is mainly caused by the increasing evaporating pressure and decreasing condensing pressure when the loads increases.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.