Respiratory motion causes errors when planning and delivering radiotherapy treatment to lung cancer patients. To reduce these errors, methods of acquiring and using four-dimensional computed tomography (4DCT) datasets have been developed. We have developed a novel method of constructing computational motion models from 4DCT. The motion models attempt to describe an average respiratory cycle, which reduces the effects of variation between different cycles. They require substantially less memory than a 4DCT dataset, are continuous in space and time, and facilitate automatic target propagation and combining of doses over the respiratory cycle. The motion models are constructed from CT data acquired in cine mode while the patient is free breathing (free breathing CT - FBCT). A "slab" of data is acquired at each couch position, with 3-4 contiguous slabs being acquired per patient. For each slab a sequence of 20 or 30 volumes was acquired over 20 seconds. A respiratory signal is simultaneously recorded in order to calculate the position in the respiratory cycle for each FBCT. Additionally, a high quality reference CT volume is acquired at breath hold. The reference volume is nonrigidly registered to each of the FBCT volumes. A motion model is then constructed for each slab by temporally fitting the nonrigid registration results. The value of each of the registration parameters is related to the position in the respiratory cycle by fitting an approximating B spline to the registration results. As an approximating function is used, and the data is acquired over several respiratory cycles, the function should model an average respiratory cycle. This can then be used to calculate the value of each degree of freedom at any desired position in the respiratory cycle. The resulting nonrigid transformation will deform the reference volume to predict the contents of the slab at the desired position in the respiratory cycle. The slab model predictions are then concatenated to produce a combined prediction over the entire region of interest. We have performed a number of experiments to assess the accuracy of the nonrigid registration results and the motion model predictions. The individual slab models were evaluated by expert visual assessment and the tracking of easily identifiable anatomical points. The combined models were evaluated by calculating the discontinuities between the transformations at the slab boundaries. The experiments were performed on five patients with a total of 18 slabs between them. For the point tracking experiments, the mean distance between where a clinician manually identified a point and where the registration results located the point, the target registration error (TRE), was 1.3 mm. The mean distance between a manually identified point and the models prediction of the point's location, the target model error (TME), was 1.6 mm. The mean discontinuity between model predictions at the slab boundaries, the Continuity Error, was 2.2 mm. The results show that the motion models perform with a level of accur...
Displaced acetabular fractures are best treated with open reduction to achieve anatomic reduction and maximize the chance of a good functional outcome. Because of the anatomic complexity and often limited visualization, fracture reduction can be difficult. Virtual planning software can allow the surgeon to understand the fracture morphology and to rehearse reduction maneuvers. The purpose of this study was to determine the effect of a novel virtual fracture reduction module on time and accuracy of reduction. Four acetabular fracture patterns were created in synthetic pelves, which were implanted with fiducial markers and were registered with CT scan. Ten surgeons used virtual fracture reduction software or conventional 2D planning methods and immediately reduced the fractures blindly in a viscous gel medium. 3D imaging was again performed and the accuracy of reduction was assessed. The average malreduction was significantly improved following planning with the virtual software compared to the standard technique. The time taken for reduction was also significantly less for two of the four fracture patterns. Virtual software may be useful for visualizing and planning treatment of fractures of the acetabulum, potentially leading to more accurate and efficient reductions, and may also be an effective educational tool. ß
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.