A stability-indicating reverse phase–high performance liquid chromatography (RP–HPLC) method was developed and validated for the determination of atazanavir sulfate in tablet dosage forms using C18 column Phenomenix (250 mm×4.6 mm, 5 μm) with a mobile phase consisting of 900 mL of HPLC grade methanol and 100 mL of water of HPLC grade. The pH was adjusted to 3.55 with acetic acid. The mobile phase was sonicated for 10 min and filtered through a 0.45 μm membrane filter at a flow rate of 0.5 mL/min. The detection was carried out at 249 nm and retention time of atazanavir sulfate was found to be 8.323 min. Linearity was observed from 10 to 90 μg/mL (coefficient of determination R2 was 0.999) with equation, y=23.427x+37.732. Atazanavir sulfate was subjected to stress conditions including acidic, alkaline, oxidation, photolysis and thermal degradation, and the results showed that it was more sensitive towards acidic degradation. The method was validated as per ICH guidelines.
A Simple, accurate and precise method was developed and validated for the determination of flucloxacillin sodium in its tablet dosage form. The separation was eluted on xterra c18 column (4.6x150mm, 5micron) using a mixture of octane buffer and methanol as mobile phase in a ratio of (30:70) which was pumped through column at a flow rate of 1ml/min. Optimised wavelength for flucloxacillin was 237nm, the retention time was 2.305minutes and the percentage purity was found to be 98.14%. System suitability parameters such as theoretical plate and tailing factor for flucloxacillin sodium was found to be 2991.64 and 1.90 respectively, the proposed method was validated as per ICH guidelines (ICH, Q2 AND (R1)) the method was found to be linear at the concentration range of 20-100µg/ml and the correlation coefficient (r2) value was found to be 0.9994 percentage RSD for precision was 0.9% and percentage RSD for ruggedness was 0.5%. The precision study was precise, robust and repeatable. The LOD and LOQ values are 2.98 and 9.98 respectively. Hence the suggested RP-HPLC method can be used for routine analysis for flucloxacillin sodium in tablet dosage form.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.