BackgroundThere is a potential for adverse cardiovascular effects in long-term breast cancer survivors following adjuvant radiotherapy (RT). For this purpose, the deep inspiration breath-hold technique (DIBH) has been introduced into clinical practice, to maximally reduce the radiation dose to the heart. However, there are a variety of DIBH delivery techniques, patient positioning and visual patient feedback mechanisms. The aim of the present study was to evaluate the application of radiotherapy in DIBH using the CatalystTM/SentinelTM system, with a special emphasis on treatment planning and dosimetric plan comparison in free breathing (FB) and DIBH.Patients and methodsA total of 13 patients with left-sided breast cancer following breast conserving surgery were included in this prospective clinical trial. For treatment application the CatalystTM/SentinelTM system (C-RAD AB, Uppsala, Sweden) was used and gating control was performed by an audio-visual patient feedback system. CT and surface data were acquired in FB and DIBH and dual treatment plans were created using Pencil Beam and Collapsed Cone Convolution. Dosimetric output parameters of organs at risk were compared using Wilcoxon signed-rank test. Central lung distance (CLD) was retrieved from iViewTM portal images during treatment delivery.ResultsThe system contains a laser surface scanner (SentinelTM) and an optical surface scanner (CatalystTM) interconnected to the LINAC systems via a gating interface and allows for a continuous and touchless surface scanning. Overall, 225 treatment fractions with audio-visual guidance were completed without any substantial difficulties. Following initial patient training and treatment setup, radiotherapy in DIBH with the CatalystTM/SentinelTM system was time-efficient and reliable. Following dual treatment planning for all patients, nine of 13 patients were treated in DIBH. In these patients, the reduction of the mean heart dose for DIBH compared to FB was 52 % (2.73 to 1.31 Gy; p = 0.011). The maximum doses to the heart and LAD were reduced by 59 % (47.90 to 19.74 Gy; p = 0.008) and 75 % (38.55 to 9.66 Gy; p = 0.008), respectively. In six of the nine patients the heart completely moved out of the treatment field by DIBH. The standard deviation of the CLD varied between 0.12 and 0.29 cm (mean: 0.16 cm).ConclusionThe CatalystTM/SentinelTM system enabled a fast and reliable application and surveillance of DIBH in daily clinical routine. Furthermore, the present data show that using the DIBH technique during RT could significantly reduce high dose areas and mean doses to the heart.Trial registration DRKS: DRKS00010929 registered on 5. August 2016.
Ideally, the DIBH technique should be offered to all patients with left-sided breast cancer. However, highest benefits are expected for patients with a favourable tumour prognosis, high mean heart dose or high baseline IHD risk, independent of their age.
Although the organ preservation strategy by breast-conserving surgery (BCS) followed by radiation therapy (BCT) has revolutionized the treatment approach of early stage breast cancer (BC), the choice between treatment options in this setting can still vary according to patient preferences. The aim of the present study was to compare the oncological outcome of mastectomy versus breast-conserving therapy in patients treated in a modern clinical setting outside of clinical trials. 7565 women diagnosed with early invasive BC (pT1/2pN0/1) between 1998 and 2014 were included in this study (median follow-up: 95.2 months). In order to reduce selection bias and confounding, a subgroup analysis of a matched 1:1 case-control cohort consisting of 1802 patients was performed (median follow-up 109.4 months). After adjusting for age, tumor characteristics and therapies, multivariable analysis for local recurrence-free survival identified BCT as an independent predictor for improved local control (hazard ratio [HR]:1.517; 95%confidence interval:1.092–2.108, p = 0.013) as compared to mastectomy alone in the matched cohort. Ten-year cumulative incidence (CI) of lymph node recurrences was 2.0% following BCT, compared to 5.8% in patients receiving mastectomy (p < 0.001). Similarly, 10-year distant-metastasis-free survival (89.4% vs. 85.5%, p = 0.013) was impaired in patients undergoing mastectomy alone. This translated into improved survival in patients treated with BCT (10-year overall survival (OS) estimates 85.3% vs. 79.3%, p < 0.001), which was also significant on multivariable analysis (p = 0.011). In conclusion, the present study showed that patients treated with BCS followed by radiotherapy had an improved outcome compared to radical mastectomy alone. Specifically, local control, distant control, and overall survival were significantly better using the conservative approach. Thus, as a result of the present study, physicians should encourage patients to receive BCS with radiotherapy rather than mastectomy, whenever it is medically feasible and appropriate.
The results indicate that 3D-CRT plans in DIBH pose the lowest risk for both major coronary events and secondary lung cancer.
Purpose/Objective:Reproducible patient positioning remains one of the major challenges in modern radiation therapy. Recently, optical surface scanners have been introduced into clinical practice in addition to well-established positioning systems, such as room laser and skin marks. The aim of this prospective study was to evaluate setup errors of the optical surface scanner Catalyst HD (C-RAD AB) in different anatomic regions.Material/Methods:Between October 2016 and June 2017 a total of 1902 treatment sessions in 110 patients were evaluated. The workflow of this study included conventional setup procedures using laser-based positioning with skin marks and an additional registration of the 3-dimensional (3D) deviations detected by the Catalyst system. The deviations of the surface-based method were then compared to the corrections of cone beam computed tomography alignment which was considered as gold standard. A practical Catalyst setup error was calculated between the translational deviations of the surface scanner and the laser positioning. Two one-sided t tests for equivalence were used for statistical analysis.Results:Data analysis revealed total deviations of 0.09 mm ± 2.03 mm for the lateral axis, 0.07 mm ± 3.21 mm for the longitudinal axis, and 0.44 mm ± 3.08 mm vertical axis for the Catalyst system, compared to −0.06 ± 3.54 mm lateral, 0.53 ± 3.47 mm longitudinal, and 0.19 ± 3.49 mm vertical for the laser positioning compared to cone beam computed tomography. The lowest positional deviations were found in the cranial region, and larger deviations occurred in the thoracic and abdominal sites. A statistical comparison using 2 one-sided t tests showed a general concordance of the 2 methods (P ≤ 0.036), excluding the vertical direction of the abdominal region (P = 0.198).Conclusion:The optical surface scanner Catalyst HD is a reliable and feasible patient positioning system without any additional radiation exposure. From the head to the thoracic and abdominal region, a decrease in accuracy was observed within a comparable range for Catalyst and laser-assisted positioning.
Purpose: Patients with left-sided breast cancer frequently receive deep inspiration breath-hold (DIBH) radiotherapy to reduce the risk of cardiac side effects. The aim of the present study was to analyze intra-breath-hold stability and inter-fraction breath-hold reproducibility in clinical practice. Material and methods: Overall, we analyzed 103 patients receiving left-sided breast cancer radiotherapy using a surface-guided DIBH technique. During each treatment session the vertical motion of the patient was continuously measured by a surface guided radiation therapy (SGRT) system and automated gating control (beam on/off) was performed using an audiovisual patient feedback system. Dose delivery was automatically triggered when the tracking point was within a predefined gating window. Intra-breath-hold stability and inter-fraction reproducibility across all fractions of the entire treatment course were analyzed per patient. Results: In the present series, 6013 breath-holds during beam-on time were analyzed. The mean amplitude of the gating window from the baseline breathing curve (maximum expiration during free breathing) was 15.8 mm (95%confidence interval: [8.5-30.6] mm) and had a width of 3.5 mm (95%-CI: [2-4.3] mm). As a measure of intra-breathhold stability, the median standard deviation of the breath-hold level during DIBH was 0.3 mm (95%-CI: [0.1-0.9] mm). Similarly, the median absolute intra-breath-hold linear amplitude deviation was 0.4 mm (95%-CI: [0.01-2.1] mm). Reproducibility testing showed good inter-fractional reliability, as the maximum difference in the breathing amplitudes in all patients and all fractions were 1.3 mm on average (95%-CI: [0.5-2.6] mm). Conclusion: The clinical integration of an optical surface scanner enables a stable and reliable DIBH treatment delivery during SGRT for left-sided breast cancer in clinical routine.
BackgroundIntra-fraction motion represents a crucial issue in the era of precise radiotherapy in several settings, including breast irradiation. To date, only few data exist on real-time measured intra-fraction motion in breast cancer patients. Continuous surface imaging using visible light offers the capability to monitor patient movements in three-dimensional space without any additional radiation exposure. The aim of the present study was to quantify the uncertainties of possible intra-fractional motion during breast radiotherapy.Material and methodsOne hundred and four consecutive patients that underwent postoperative radiotherapy following breast conserving surgery or mastectomy were prospectively evaluated during 2028 treatment sessions. During each treatment session the patients’ motion was continuously measured using the Catalyst™ optical surface scanner (C-RAD AB, Sweden) and compared to a reference scan acquired at the beginning of each session. The Catalyst system works through an optical surface imaging with light emitting diode (LED) light and reprojection captured by a charge coupled device (CCD) camera, which provide target position control during treatment delivery with a motion detection accuracy of 0.5 mm. For 3D surface reconstruction, the system uses a non-rigid body algorithm to calculate the distance between the surface and the isocentre and using the principle of optical triangulation. Three-dimensional deviations and relative position differences during the whole treatment fraction were calculated by the system and analyzed statistically.ResultsOverall, the maximum magnitude of the deviation vector showed a mean change of 1.93 mm ± 1.14 mm (standard deviation [SD]) (95%-confidence interval: [0.48–4.65] mm) and a median change of 1.63 mm during dose application (beam-on time only). Along the lateral and longitudinal axis changes were quite similar (0.18 mm ± 1.06 mm vs. 0.17 mm ± 1.32 mm), on the vertical axis the mean change was 0.68 mm ± 1.53 mm. The mean treatment session time was 154 ± 53 (SD) seconds and the mean beam-on time only was 55 ± 16 s. According to Friedman’s test differences in the distributions of the three possible directions (lateral, longitudinal and vertical) were significant (p < 0.01), in post-hoc analysis there were no similarities between any two of the three directions.ConclusionThe optical surface imaging system is an accurate and easy tool for real-time motion management in breast cancer radiotherapy. Intra-fraction motion was reported within five millimeters in all directions. Thus, intra-fraction motion in our series of 2028 treatment sessions seems to be of minor clinical relevance in postoperative radiotherapy of breast cancer.
A sequential neoadjuvant chemo-/radiotherapy to allow IBR following mastectomy in selected cases of LABC seems feasible and can be safely attempted. Careful patient selection, close monitoring, and continuous patient support is mandatory to ensure compliance in this treatment strategy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.