Background: β-decay spectroscopy provides valuable information on exotic nuclei and a stringent test for nuclear theories beyond the stability line. Purpose: To search for new β-delayed protons and γ rays of 25 Si to investigate the properties of 25 Al excited states. Method: 25 Si β decays were measured by using the Gaseous Detector with Germanium Tagging system at the National Superconducting Cyclotron Laboratory. The protons and γ rays emitted in the decay were detected simultaneously. A Monte Carlo method was used to model the Doppler broadening of 24 Mg γ-ray lines caused by nuclear recoil from proton emission. Shell-model calculations using two newly-developed sd-shell Hamiltonians, USDC and USDI, were performed. Results: The most precise 25 Si half-life to date has been determined. A new proton branch at 724(4) keV and new proton-γ-ray coincidences have been identified. Three 24 Mg γ-ray lines and eight 25 Al γ-ray lines are observed for the first time in 25 Si decay. The first measurement of the 25 Si β-delayed γ ray intensities through the 25 Al unbound states is reported. All the bound states of 25 Al are observed to be populated in the β decay of 25 Si. Several inconsistencies between the previous measurements have been resolved, and new information on the 25 Al level scheme is provided. An enhanced decay scheme has been constructed and compared to the mirror decay of 25 Na and the shell-model calculations. Conclusions: The measured excitation energies, γ-ray and proton branchings, log f t values, and Gamow-Teller transition strengths for the states of 25 Al populated in the β decay of 25 Si are in good agreement with the shell model calculations, offering gratifyingly consistent insights into the fine nuclear structure of 25 Al.
Nursing leaders must build a learning organization and an environment where colleagues can flourish. Enhance professional knowledge of self-care while maintaining stable donor blood donation. Create a good initial impression with blood donors and deepen the quality of service. Support coworkers and nurses. In accordance with the Medical Device Manual and Standard Operating Procedure, conduct regular inspections and audits to ensure normal operation of blood donation instruments. Under the internal audit mechanism, individually verify and correct missing files and submit the report. Improve professional knowledge, maintain the enthusiasm and technical level of medical personnel and provide the most appropriate services for blood donors.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.