We study the impact of coil orientation on the motor threshold (MT) and present an optimal coil orientation for stimulation of the foot. The result can be compared to results of models that predict this orientation from electrodynamic properties of the media in the skull and from orientations of cells, respectively. We used a robotized TMS system for precise coil placement and recorded motor-evoked potentials with surface electrodes on the abductor hallucis muscle of the right foot in 8 healthy control subjects. First, we performed a hot-spot search in standard (lateral) orientation and then rotated the coil in steps of 10° or 20°. At each step we estimated the MT. For navigated stimulation and for correlation with the underlying anatomy a structural MRI scan was obtained. Optimal coil orientation was 33.1±18.3° anteriorly in relation to the standard lateral orientation. In this orientation the threshold was 54±18% in units of maximum stimulator output. There was a significant difference of 8.0±5.9% between the MTs at optimal and at standard orientation. The optimal coil orientations were significantly correlated with the direction perpendicular to the postcentral gyrus (). Robotized TMS facilitates sufficiently precise coil positioning and orientation to study even small variations of the MT with coil orientation. The deviations from standard orientation are more closely matched by models based on field propagation in media than by models based on orientations of pyramidal cells.
Abstract-The commission of an error triggers cognitive control processes dedicated to error correction and prevention. Post-error adjustments leading to response slowing following an error (''post-error slowing''; PES) might be driven by changes in excitability of the motor regions and the corticospinal tract (CST). The time-course of such excitability modulations of the CST leading to PES is largely unknown. To track these presumed excitability changes after an error, single pulse transcranial magnetic stimulation (TMS) was applied to the motor cortex ipsilateral to the responding hand, while participants were performing an Eriksen flanker task. A robotic arm with a movement compensation system was used to maintain the TMS coil in the correct position during the experiment. Magnetic pulses were delivered over the primary motor cortex ipsilateral to the active hand at different intervals (150, 300, 450 ms) after correct and erroneous responses, and the motor-evoked potentials (MEP) of the first dorsal interosseous muscle (FDI) contralateral to the stimulated hemisphere were recorded. MEP amplitude was increased 450 ms after the error. Two additional experiments showed that this increase was neither associated to the correction of the erroneous responses nor to the characteristics of the motor command. To the extent to which the excitability of the motor cortex ipsi-and contralateral to the response hand are inversely related, these results suggest a decrease in the excitability of the active motor cortex after an erroneous response. This modulation of the activity of the CST serves to prevent further premature and erroneous responses. At a more general level, the study shows the power of the TMS technique for the exploration of the temporal evolution of post-error adjustments within the motor system. Ó
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.