Electric fields produced by a selection of video display units have been measured over a frequency range from DC to 1 MHz. The magnitude and the time variation of the electric fields were both recorded by means of a single broadband capacitive sensor located on the surface of a simple simulation of the human body. The electric field at a given location was found to be the sum of three discrete components, each having a different spatial and time variation. These components are produced by, respectively, the charged CRT screen, the flyback transformer, and the low-voltage circuitry. For the units tested, operator exposures are substantially below the limits of existing workplace guidelines.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.