We performed denaturing gradient gel electrophoresis (DGGE) of exons 4, 5, 6 and their exon-intron boundaries of the LPL-gene in 169 unrelated male patients suffering from familial combined hyperlipidemia (FCH). Twenty patients were found to carry a nucleotide substitution in exon 6. Sequence and PCR/digestion analysis revealed one common mutation (Asn291Ser) in all these cases. This mutation was talso present in 215 male controls, albeit at a lower frequency than in FCH patients (10/215 = 4.6% vs. 20/169 = 11.8%; p < 0.02). Analysis of lipid, lipoprotein and apolipoprotein levels demonstrated an association between the presence of this Asn291Ser substitution and decreased HDL-cholesterol (0.94 +/- 0.31 vs. 1.12 +/- 0.26 mmol/l; p < 0.04) in our controls. FCH patients carrying this mutation showed decreased HDL-cholesterol (0.75 +/- 0.16 vs. 0.95 +/- 0.36 mmol/l; p = 0.05) and increased triglyceride levels (5.96 +/- 4.12 vs. 3.48 +/- 1.78 mmol/l; p < 0.005) compared to non-carriers. The high triglyceride and low HDL-cholesterol phenotype in carriers of this substitution was most obvious when BMI exceeded 27 kg/m2. Our study of male FCH patients revealed the presence of a common mutation in the LPL-gene that is associated with lipoprotein abnormalities, indicating that defective LPL is at least one of the factors contributing to the FCH-phenotype.
Background: Cardiotocography (CTG) is worldwide the method for fetal surveillance during labour. However, CTG alone shows many false positive test results and without fetal blood sampling (FBS), it results in an increase in operative deliveries without improvement of fetal outcome. FBS requires additional expertise, is invasive and has often to be repeated during labour. Two clinical trials have shown that a combination of CTG and ST-analysis of the fetal electrocardiogram (ECG) reduces the rates of metabolic acidosis and instrumental delivery. However, in both trials FBS was still performed in the ST-analysis arm, and it is therefore still unknown if the observed results were indeed due to the ST-analysis or to the use of FBS in combination with ST-analysis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.