IntroductionThe incidence of postoperative thrombocytopenia after aortic valve replacement (AVR) with the Perceval S Sutureless bioprosthesis remains unclear. The aim of this study was to report thrombocytopenia associated with the use of sutureless AVR.MethodsThe data was collected retrospectively for patients who had isolated AVR with sutureless Perceval S valve (Group A: 72 patients) and was compared with patients who underwent isolated sutured AVR with Perimount Magna Ease Bioprosthesis (Group B: 101 patients) in our institution between June 2014 and January 2017.ResultsCardiopulmonary bypass and cross-clamp time were significantly shorter in group A. Maximum drop in platelet count was 58% mean (day 2.3) in group A versus 44% mean (day 1.7) in group B (P=0.0001). Absolute platelet count on postoperative day 1-6 in group A was significantly less than in group B (P≤0.05). Platelet count recovered to preoperative value in 44% patients in group B versus only in 26% patients in group A at discharge (P=0.018). Moderate thrombocytopenia occurs more often in group A (41% vs. 26%) (P=0.008) while severe thrombocytopenia (<50 x 109) was observed in 6% in group A but never in group B. Platelets (P=0.007) and packed red blood cells (P=0.009) transfusion was significantly higher in the group A.ConclusionThe implantation of sutureless Perceval aortic valves was associated with a significant drop in platelet count postoperatively with slow recovery and higher platelets and packed red blood cells transfusion requirements. A prospective randomised trial is needed to confirm our findings.
Recent evidence suggests that the production of colorectal carcinogens is facilitated when the pH of the colonic contents is alkaline. It follows that the colonic intraluminal pH of patients with colorectal neoplasms should be higher than in normal subjects. Gastrointestinal pH has been measured in 30 patients with colorectal cancer and 37 patients with benign colorectal adenomas (using a pH sensitive radiotelemetry capsule). These values have been compared with those recorded in 66 normal subjects. No differences in gastrointestinal pH were found and the results did not support the hypothesis that colonic pH plays a role in the aetiology of colorectal neoplasia.
ObjectiveThe aim of this retrospective study was to compare early postoperative outcomes after aortic valve replacement (AVR) with sutureless bioprostheses and conventional stented bioprostheses implanted through median sternotomy.MethodsFrom January 2011 to December 2016, 763 patients underwent aortic valve replacement with bioprostheses; of these, 139 received a Perceval S sutureless valve (Group A) and 624 received a Perimount Magna Ease valve (Group B). These groups were further divided into A1 (isolated Perceval AVR), A2 (Perceval AVR with coronary artery bypass grafting [CABG]), B1 (isolated conventional stented bioprosthesis), and B2 (conventional stented bioprosthesis + CABG).ResultsPatients in Group A were older (mean 74 years vs. 71 years; P<0.0001), predominantly women (53% vs. 32%; P<0.0001), had a higher logistic EuroSCORE (3.26 vs. 2.43; P<0.001), more preoperative atrial fibrillation (20% vs. 13%; P=0.03), and had a lower reopening rate for bleeding (2.1% vs. 6.7%; P=0.04). Compared to Group B1, Group A1 had shorter cross-clamp (mean 40 min vs. 57 min; P≤0.0001) and bypass times (mean 63 min vs. mean 80 min; P=0.02), and they bled less postoperatively (mean 295 ml vs. mean 393 ml; P=0.002). The mean gradient across Perceval valve was 12.5 mmHg while its effective orifice area was 1.5 cm2.ConclusionIn our retrospective study of 763 patients, sutureless valve group patients are older, mostly women, more symptomatic preoperatively, and have higher logistic EuroSCORE. They have shorter cross-clamp and bypass times, less postoperative bleeding, and reduced incidence of reopening. Further studies are needed to evaluate the clinical benefits in short, mid, and long-terms.
ObjectiveThe aim of this retrospective study is to evaluate the safety and performance of the Perceval sutureless valve in patients undergoing aortic valve replacement. We report the 30-day clinical outcomes of 139 patients.MethodsFrom January 2014 to December 2016, 139 patients underwent sutureless aortic valve replacement. Their operation notes, National Adult Cardiac Surgery Database and perioperative transoesophageal echocardiography findings were studied retrospectively.ResultsNinety-two patients underwent isolated aortic valve replacement (group A) with Perceval valve and 47 patients had combined procedures of aortic valve replacement and coronary artery bypass grafting (group B). The patients received a size S (n=23), M (n=39), L (n=42) or XL (n=35) prosthesis. Perceval valve was successfully implanted in 135 (97.1%) patients. Mean cross-clamping time and bypass time were 40 and 63 minutes for isolated cases, while 68 and 107 minutes for combined cases. Three (2.1%) patients died within 30 days. Four patients suffered stroke and 5 patients went into acute renal failure. Median intensive care unit and hospital stay was 2 and 8.5, respectively. Four valves were explanted due to significant paravalvular leak after surgery. Five patients had permanent pacemaker as a result of complete heart block and mean postoperative drainage was 295 mL for isolated case and 457 mL for combined cases. The mean gradient across Perceval valve was 12.5 mmHg while its effective orifice area was 1.5 cm2.ConclusionEarly postoperative results showed that Perceval valve is safe. Further follow up is needed to evaluate the long-term outcome with this bioprosthesis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.