Resting-state, low frequency (< 0.08 Hz) fluctuations of blood oxygenation level dependent (BOLD) magnetic resonance signal have been shown to exhibit high correlation among functionally connected regions. However, correlations of cerebral blood flow (CBF) fluctuations during the resting state have not been extensively studied. The main challenges of using arterial spin labeling perfusion magnetic resonance imaging to detect CBF fluctuations are low sensitivity, low temporal resolution, and contamination from BOLD. This work demonstrates CBF-based quantitative functional connectivity mapping by combining continuous arterial spin labeling (CASL) with a neck labeling coil and a multi-channel receiver coil to achieve high perfusion sensitivity. In order to reduce BOLD contamination, the CBF signal was extracted from the CASL signal time course by high frequency filtering. This processing strategy is compatible with sinc interpolation for reducing the timing mismatch between control and label images and has the flexibility of choosing an optimal filter cutoff frequency to minimize BOLD fluctuations. Most subjects studied showed high CBF correlation in bilateral sensorimotor areas with good suppression of BOLD contamination. Root-mean-square CBF fluctuation contributing to bilateral correlation was estimated to be 29% ± 19% (N = 13) of the baseline perfusion, while BOLD fluctuation was 0.26% ± 0.14% of the mean intensity (at 3T and 12.5 ms echo time).
A variety of continuous and pulsed arterial spin labeling (ASL) perfusion MRI techniques have been demonstrated in recent years. One of the reasons these methods are still not routinely used is the limited extent of the imaging region. Of the ASL methods proposed to date, continuous ASL (CASL) with a separate labeling coil is particularly attractive for whole-brain studies at high fields. This approach can provide an increased signal-to-noise ratio (SNR) in perfusion images because there are no magnetization transfer (MT) effects, and lessen concerns regarding RF power deposition at high field because it uses a local labeling coil. In this work, we demonstrate CASL whole-brain quantitative perfusion imaging at 3.0 T using a combination of strategies: 3D volume acquisition, background tissue signal suppression, and a separate labeling coil. The results show that this approach can be used to acquire perfusion images in all brain regions with good sensitivity. Further, it is shown that the method can be performed safely on humans without exceeding the current RF power deposition limits. The current method can be extended to higher fields, and further improved by the use of multiple receiver coils and parallel imaging techniques to reduce scan time or provide increased resolution.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.