Results from a search for neutrinoless double-beta decay (0νββ) of ^{136}Xe are presented using the first year of data taken with the upgraded EXO-200 detector. Relative to previous searches by EXO-200, the energy resolution of the detector has been improved to σ/E=1.23%, the electric field in the drift region has been raised by 50%, and a system to suppress radon in the volume between the cryostat and lead shielding has been implemented. In addition, analysis techniques that improve topological discrimination between 0νββ and background events have been developed. Incorporating these hardware and analysis improvements, the median 90% confidence level 0νββ half-life sensitivity after combining with the full data set acquired before the upgrade has increased twofold to 3.7×10^{25} yr. No statistically significant evidence for 0νββ is observed, leading to a lower limit on the 0νββ half-life of 1.8×10^{25} yr at the 90% confidence level.
We report on an improved measurement of the 2νββ half-life of 136 Xe performed by EXO-200. The use of a large and homogeneous time projection chamber allows for the precise estimate of the fiducial mass used for the measurement, resulting in a small systematic uncertainty. We also discuss in detail the data analysis methods used for double-beta decay searches with EXO-200, while emphasizing those directly related to the present measurement. The 136 Xe 2νββ half-life is found to be T 2νββ 1/2 = 2.165 ± 0.016(stat) ± 0.059(sys) · 10 21 years. This is the most precisely measured half-life of any 2νββ decay to date.
The scattering of dark matter (DM) particles with sub-GeV masses off nuclei is difficult to detect using liquid xenon-based DM search instruments because the energy transfer during nuclear recoils is smaller than the typical detector threshold. However, the tree-level DM-nucleus scattering diagram can be accompanied by simultaneous emission of a Bremsstrahlung photon or a so-called "Migdal" electron. These provide an electron recoil component to the experimental signature at higher energies than the corresponding nuclear recoil. The presence of this signature allows liquid xenon detectors to use both the scintillation and the ionization signals in the analysis where the nuclear recoil signal would not be otherwise visible. We report constraints on spin-independent DM-nucleon scattering
Future tonne-scale liquefied noble gas detectors depend on efficient light detection in the VUV range. In the past years Silicon Photomultipliers (SiPMs) have emerged as a valid alternative to standard photomultiplier tubes or large area avalanche photodiodes. The next generation double beta decay experiment, nEXO, with a 5 tonne liquid xenon time projection chamber, will use SiPMs for detecting the 175 nm xenon scintillation light, in order to achieve an energy resolution of σ/Qββ = 1 %. This paper presents recent measurements of the VUV-HD generation SiPMs from Fondazione Bruno Kessler in two complementary setups. It includes measurements of the photon detection efficiency with gaseous xenon scintillation light in a vacuum setup and dark measurements in a dry nitrogen gas setup. We report improved photon detection efficiency at 175 nm compared to previous generation devices, that would meet the criteria of nEXO. Furthermore, we present the projected nEXO detector light collection and energy resolution that could be achieved by using these SiPMs. Index Terms-silicon photomultiplier, xenon detectors, photo detectors, vacuum ultra-violet light, nEXO I. NEUTRINO-LESS DOUBLE BETA DECAY AND NEXO N eutrino-less double beta decay (0νββ) is a hypothetical nuclear decay where two neutrons decay into two protons and two electrons are emitted but no anti-neutrinos are present in the final state. The observation of this process would have a fundamental impact on the Standard Model of Particle Physics, specifically showing a violation of lepton number conservation (|∆L| = 2), and would imply that the neutrino is a Majorana fermion [1], independently of the actual process enabling the decay [2]. Furthermore, the half-life of the decay would shed light on the absolute neutrino mass scale [3]. The nEXO collaboration plans to build a cylindrical singlephase time projection chamber (TPC) filled with 5 tonnes of liquid xenon (LXe), with 90 % enrichment in 136 Xe [4]. nEXO takes advantage of the experience from its predecessor EXO-200 [5], but will incorporate new light and charge detectors [6]. Together with cold electronics sitting inside the LXe, this allows nEXO to achieve an energy resolution of σ/Q ββ = 1 % for the 0νββ decay of 136 Xe (2458.07 ± 0.31 keV [7], [8]).In particular, instead of the EXO-200 Large Area Avalanche Photo-diodes (LAAPDs), nEXO will use Silicon Photomultipliers (SiPMs) for the detection of xenon scintillation light. The SiPMs will fully cover the lateral surface of the cylinder with a total photo-sensitive area of about 4 m 2 , as shown in Figure 1. The devices will be immersed in LXe and placed in the high field region behind the field shaping rings of the TPC field cage [9]. The performance of SiPMs has improved significantly over the past decade and they are especially interesting because of their high gain, on the order of 10 6 , and their single photon resolution capability.The half-life sensitivity of nEXO to the 0νββ decay of 136 Xe is projected to be 9.5 × 10 27 yr for 90 % C.L. after 10 years o...
Dual-phase xenon detectors, as currently used in direct detection dark matter experiments, have observed elevated rates of background electron events in the low energy region. While this background negatively impacts detector performance in various ways, its origins have only been partially studied. In this paper we report a systematic investigation of the electron pathologies observed in the LUX dark matter experiment. We characterize different electron populations based on their emission intensities and their correlations with preceding energy depositions in the detector. By studying the background under different experimental conditions, we identified the leading emission mechanisms, including photoionization and the photoelectric effect induced by the xenon luminescence, delayed emission of electrons trapped under the liquid surface, capture and release of drifting electrons by impurities, and grid electron emission. We discuss how these backgrounds can be mitigated in LUX and future xenon-based dark matter experiments.
The EXO-200 Collaboration is searching for neutrinoless double beta decay using a liquid xenon (LXe) time projection chamber. This measurement relies on modeling the transport of charge deposits produced by interactions in the LXe to allow discrimination between signal and background events. Here we present measurements of the transverse diffusion constant and drift velocity of electrons at drift fields between 20 V/cm and 615 V/cm using EXO-200 data. At the operating field of 380 V/cm EXO-200 measures a drift velocity of 1.705 +0.014 −0.010 mm/µs and a transverse diffusion coefficient of 55±4 cm 2 /s.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.