Purpose Small field dosimetry has been an active area of research for over a decade. It is now known that large dosimetric errors can be introduced if proper detectors or correction factors are not used. The International Atomic Energy Agency (IAEA) through the technical report series No. 483 provides guidelines for small field dosimetry procedures as well as correction factors for most detectors available in the market. The plastic scintillator detector (PSD) Exradin W1 has been found to have a correction factor close to unity; however, it is not designed for beam scanning. To overcome this limitation, the new PSD Exradin W2 has been developed to be used as a scanning as well as a relative dosimeter. Characterization of this detector in small field dosimetry is presented in this study. Methods A 6 MV beam from a Varian‐Edge linac was used to collect data for the characterization of a W2 detector. Cerenkov light ratio (CLR) is corrected through a separate new electrometer system that comes with the W2 detector. The parameters investigated include the dose and dose rate linearity, beam profiles, percent depth dose (PDD), field output factors, and temperature response. The results were compared with Gafchromic film (EBT‐3 film) for beam profiles. The field output factor and temperature response were compared to the Exradin W1 detector. Results The dose linearity measured with 600 MU/min dose rate showed minimal variations (<0.5%) even for small MU, and similar results were seen for dose rate linearity. The comparison of field output factors between the W2 and W1 showed small differences for various depth and field sizes. The temperature response showed small variation when the temperature was varied from 6∘C to 50∘C. The slope was −0.0017false/∘C and −0.0016false/∘C for the W2 and the W1 detector, respectively. The differences in profiles are 0.5% in umbra and penumbra region for 1×1cm2 field size when compared to the EBT‐3 film profile. Conclusions The W2 scintillator detector showed similar dosimetric and temperature properties to the W1 scintillator detector. The main advantage of the W2 detector among other plastic scintillators is the beam scanning capabilities that, combined with its correction factor of 1.0, make it an ideal detector for commissioning of SRS and SBRT techniques.
Independent verification of the dose per monitor unit (MU) to deliver the prescribed dose to a patient has been a mainstay of radiation oncology quality assurance (QA). We discuss the role of secondary dose/MU calculation programs as part of a comprehensive QA program. This report provides guidelines on calculationbased dose/MU verification for intensity modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT) provided by various modalities. We provide a review of various algorithms for "independent/second check" of monitor unit calculations for IMRT/VMAT. The report makes recommendations on the clinical implementation of secondary dose/MU calculation programs; on commissioning and acceptance of various commercially available secondary dose/MU calculation programs; on benchmark QA and periodic QA; and on clinically reasonable action levels for agreement of secondary dose/MU calculation programs. | REPORT OF AAPM TASK GROUP 219 ON INDEPENDENT CALCULATION-BASED DOSE/ MU VERIFICATION FOR IMRT
A trend is underway toward the use of prepackaged low dose rate brachytherapy sources, which come in the form of strands, coiled line sources, preloaded needles, and sterile cartridge packs. Since the medical physicist is responsible for verification of source strength prior to patient treatment, development of prepackaged source strength verification methods is needed. Existing guidelines are reviewed to establish the situation that medical physicists find with respect to prepackaged sources. This investigation presents an experimental evaluation of the effect of some of these multiseed geometries on source strength measurements. Multiseed strands and coils, whether 125I, 103Pd, or 192Ir can be measured in a chamber with a long, sensitive axial length with a uniform response. Sterile seed cartridge packs can also be measured but require a correction factor to be applied. Sources in needles, however, cannot be measured in the needle since there is too great a variation in needle composition and needle tolerance thickness. Removing these seeds from the needle into a sterile measurement insert, which maintains sterility is a practical source strength verification method, similar to those done for multiple seed configurations in a well chamber with adequate axial uniformity. Values are compared with individual air kerma strength calibrations, and correction factors, are presented' where needed. In each case, care must be taken to maintain sterility as multiple seeds are measured in well chamber inserts.
(1) Background: The Exradin W2 is a commercially available scintillator detector designed for reference and relative dosimetry in small fields. In this work, we investigated the performance of the W2 scintillator in a 10 MV flattening-filter-free photon beam and compared it to the performance of ion chambers designed for small field measurements. (2) Methods: We measured beam profiles and percent depth dose curves with each detector and investigated the linearity of each system based on dose per pulse (DPP) and pulse repetition frequency. (3) Results: We found excellent agreement between the W2 scintillator and the ion chambers for beam profiles and percent depth dose curves. Our results also showed that the two-voltage method of calculating the ion recombination correction factor was sufficient to correct for the ion recombination effect of ion chambers, even at the highest DPP. (4) Conclusions: These findings show that the W2 scintillator shows excellent agreement with ion chambers in high DPP conditions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.