Biopsy is the standard method for the diagnosis of prostate cancer; however, it is inadequate for the assessment of lymph node invasion. Radionuclide imaging might be useful for both diagnosis and N staging, but it requires high uptake of radiotracers in order to overcome difficulties arising from the anatomy of the region. The aim of this study was to assess whether or not technetium-99m labelled bombesin (99mTc-BN) scan is able to detect prostate cancer and invasion of pelvic lymph nodes. Ten patients were studied with 99mTc-BN, transrectal ultrasonography, biopsy, computed tomography and magnetic resonance imaging. All the patients with cancer were operated on. Planar dynamic scintigraphy and single-photon emission tomography (SPET) were performed after administration of 185 MBq 99mTc-BN. Two patients showed benign adenoma and eight showed cancer at biopsy. The average Gleason's score was 7.5+/-1.3. 99mTc-BN dynamic planar scan showed hot spots in the prostatic fossa in two of the eight patients with cancer, both of whom had a prostate-specific antigen level higher than 20 ng/ml. In these patients, high uptake inside the prostatic fossa was detected as early as 1 min after injection, before the arrival of radioactivity in the bladder. True positive SPET scans were obtained in all eight patients with cancer. Invasion of the obturator nodes was detected by SPET in three patients, and in all three was confirmed at surgery. Our preliminary data encourage further studies on the prostate with 99mTc-BN. If the high sensitivity of 99mTc-BN SPET is confirmed, this method may play an important role in diagnosing and staging prostate cancer.
Background. Total thyroidectomy (TT) is recommended in the treatment of malignant and benignant thyroid diseases, and, to date, transient hypocalcemia is the most frequent complication after the procedure. We prospectively evaluated the role of vitamin D deficiency as a predictor of postoperative hypocalcemia. Methods. This is a prospective cohort study which was conducted between January 2016 and April 2019. A total of 177 consecutive patients (141 (79.7%) women and 36 (20.3%) men) who underwent TT were included in the current study. Hypocalcemia occurred when serum calcium levels were below 8.0 mg/dL or 1.10 mmol/L. Patients were divided into two groups (Group 1, normocalcemic; Group 2, hypocalcemic) and were assessed taking into consideration preoperative serum 25-hydroxy vitamin D (25-OHD) levels, preoperative serum calcium levels, thyroid hormone levels, sex, body mass index (BMI), and smoking habits. Vitamin D deficiency was defined as 25-OHD levels <25 ng/mL. Results. The incidence of postoperative asymptomatic and symptomatic hypocalcemia in the two groups was 19.8% and 15.8%, respectively. Preoperative 25-OHD level was significantly different between Group 1 and Group 2 (31.5 ± 15.0 ng/mL vs 18.7 ± 9.8 ng/mL,p=0.017). Logistic regression analysis revealed that preoperative vitamin D deficiency was a significant predictive factor of postoperative hypocalcemia (p=0.012), and, specifically, the risk of hypocalcemia increased 15-fold in patients with a preoperative vitamin D level <25 ng/mL (odds ratio [OR], 14.8). Conclusions. Postoperative hypocalcemia is significantly associated with low preoperative levels of serum 25-OHD. Our studies demonstrate that vitamin D deficiency (<25 ng/mL) is an independent predictive factor of postoperative hypocalcemia.
Heart valve diseases are usually treated by surgical intervention addressed for the replacement of the damaged valve with a biosynthetic or mechanical prosthesis. Although this approach guarantees a good quality of life for patients, it is not free from drawbacks (structural deterioration, nonstructural dysfunction, and reintervention). To overcome these limitations, the heart valve tissue engineering (HVTE) is developing new strategies to synthesize novel types of valve substitutes, by identifying efficient sources of both ideal scaffolds and cells. In particular, a natural matrix, able to interact with cellular components, appears to be a suitable solution. On the other hand, the well-known Wharton's jelly mesenchymal stem cells (WJ-MSCs) plasticity, regenerative abilities, and their immunomodulatory capacities make them highly promising for HVTE applications. In the present study, we investigated the possibility to use porcine valve matrix to regenerate in vitro the valve endothelium by WJ-MSCs differentiated along the endothelial lineage, paralleled with human umbilical vein endothelial cells (HUVECs), used as positive control. Here, we were able to successfully decellularize porcine heart valves, which were then recellularized with both differentiated-WJ-MSCs and HUVECs. Data demonstrated that both cell types were able to reconstitute a cellular monolayer. Cells were able to positively interact with the natural matrix and demonstrated the surface expression of typical endothelial markers. Altogether, these data suggest that the interaction between a biological scaffold and WJ-MSCs allows the regeneration of a morphologically well-structured endothelium, opening new perspectives in the field of HVTE.
The commonly used gamma probes are easy to use but also give rough information when employed in radioisotope-guided surgery. When images are required for exact localization, a gamma camera as well as a probe have to be used. Position-sensitive photomultipliers have contemporaneously allowed high-resolution scintigraphy and miniaturization of gamma cameras. We have assembled a miniature gamma camera with a 1-square-inch field of view and an intrinsic resolution of about 1 mm. When the minicamera is collimated with a large-holed, highly sensitive collimator, it acquires a spatial resolution of 3 mm. This prototype has been tested in the detection of difficult-to-image breast cancer sentinel nodes. Five nodes that had not been found with the usual technique of an Anger camera plus conventional probe were checked with the miniature camera that we named imaging probe: it actually is small enough to be used as a probe and large enough to give an image. One of the five nodes was found and imaged. It was small, disease-free, close to the tumor and probably hidden by the Compton halo around the peritumoral injection site. Our pilot study shows that the imaging probe, although still a prototype, has certain advantages over conventional methods when lymph node localization is required during surgery.
Introduction. Intersigmoid hernia is a hernia of the small bowel into the intersigmoid fossa. It is well known to be a rare condition. Recent reports reveal that the preoperative differentiation of intersigmoid hernias is difficult and the diagnosis is often confirmed during the laparotomic exploration. Due to the vague clinical manifestation in most cases, the surgical treatment is frequently delayed. Materials and Methods. In this study, we systematically reviewed the literature up to 2019 covering 114 studies and 124 patients with an intersigmoid hernia. The purpose of this work is to improve the understanding of the anatomical aspects, clinical presentation, diagnosis, and treatment of intersigmoid hernia so as to assist the preoperative differentiation of these hernias when presented as acute abdomen in the emergency department. Results. The diameter of the intersigmoid recess was reported with mean 2.65 cm (range 1–10 cm, SD 1.15 cm) and the length of the incarcerated small intestine was between 3 cm (min) and 150 cm (max): mean 25.25 cm, SD 35.04 cm. The diameter of the sigmoid recess was greater in patients who underwent resection due to strangulation (mean 3.31 cm, SD 1.53 cm) compared to those who underwent only reduction of the hernia (mean 2.35 cm, SD 0.74 cm). The time from onset to operation was less in patients undergoing resection surgery due to throttling (mean 3.03 days, SD 3.01 days) compared to those who underwent only a reduction of hernia incarceration (mean 8.49 days, SD 6.83 days). Conclusion. Intersigmoid hernia is often a forgotten diagnosis and a clinical challange due to its anatomical characteristics.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.