The removal of natural organic matter (NOM) using a continuous flow fixed bed granular activated carbon (GAC) column was studied and the results were then fitted with the Adams-Bohart, Bed-Depth-Service-Time and Clarks models. The GAC, KI-6070 and KI-8085 used in the study had external surface areas of 277 m2/g and 547 m2/g, respectively. Adsorption of NOM by the GAC was complex and involved more than one rate-limiting step. The critical bed depths for KI-6070 and KI-8085 were 0.24 m and 0.3 m, respectively. The Clark model was more effective in simulating the absorbent breakthrough process as compared to the Adams-Bohart model. The lower empty bed contact time (EBCT) i.e. 15 minutes gave a better fit to the Clark Model as compared to EBCT of 20 and 30 minutes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.