Two new methods for the detection of antibodies to Toxoplasma gondii, an enzyme-linked immunosorbent assay and a quantitative immunofluorescence assay, were evaluated and compared with the conventional indirect fluorescent-antibody slide test. Each of 100 human sera was assayed twice by the three procedures. Both the enzyme-linked immunosorbent assay and the quantitative immunofluorescence assay correlated well with serologically positive (indirect fluorescent-antibody titer greater than or equal to 1:32) and negative sera. The enzyme-linked immunosorbent assay was more specific, but less sensitive, than the quantitative immunofluorescence assay. However, the quantitative immunofluorescence assay was more reproducible and more rapid than the enzyme-linked immunosorbent assay.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.