This paper discusses the experimental examination of anisotropic steel-made samples subjected to a static stress load. A nondestructive testing (NDT) measurement system with a transducer, which enables observation of local hysteresis loops and detection of samples’ inhomogeneity, is proposed. Local hysteresis loops are measured on two perpendicular axes, including one parallel to the rolling direction of the samples. The results confirm that the selected features of the local hysteresis loops provide important information about the conditions of ferromagnetic materials. Furthermore, it is shown that the selected parameters of the statistical analysis of the achieved measurements are beneficial for evaluating stress and fatigue changes induced in the material.
This paper proposes and experimentally investigates a novel nondestructive testing method for ferromagnetic elements monitoring, the Magnetic Recording Method (MRM). In this method, the inspected element must be magnetized in a strictly defined manner before operation. This can be achieved using an array of permanent magnets arranged to produce a quasi-sinusoidal magnetization path. The magnetic field caused by the original residual magnetization of the element is measured and stored for future reference. After the operation or loading, the magnetic field measurement is repeated. Analysis of relative changes in the magnetic field (for selected components) allows identifying applied stress. The proposed research methodology aims to provide information on the steel structure condition unambiguously and accurately. An interpretation of the results without referring to the original magnetization is also possible but could be less accurate. The method can be used as a standard technique for NDT (Non-Destructive Testing) or in structural health monitoring (SHM) systems.
This paper shows an experimental investigation of the steel-made samples using a novel nondestructive testing technique, the Magnetic Recording Method (MRM). The technique is intended to examine stress or fatigue-loaded ferromagnetic structures. First, the material has to be magnetized (e.g. using an array of permanent magnets) to obtain a specific magnetization path with a quasi-sinusoidal shape. Then, remanence is measured and recorded for further analysis. After the operation or static stress load, the measurement is repeated. Analysis of the relative change in magnetization enables applied stress to be identified unequivocally.
This paper presents the results of experiments using the eddy current system designated for nondestructive inspection of carbon fiber-reinforced composites. For this purpose, the eddy current testing system with a differential transducer with two pairs of excitation coils oriented perpendicularly and a central pick-up coil was utilized. The transducer measures the magnetic flux difference flowing through the pick-up coil. The transducer of this design has already been successfully utilized to inspect isotropic metal structures. However, the anisotropy of the composites and their lower conductivity compared to metal components made the transducer parameters adjustment essential. Thus, various excitation frequencies were considered and investigated. The system was evaluated using a sample made of orthogonally woven carbon fiber-reinforced composites with two artificial flaws (the notches with a maximum relative depth of 30% and 70%, respectively, thickness of 0.4 mm, and a length of 5 mm). The main goal was to find a configuration suitable for detecting hidden flaws in such materials.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.