Increased flow resistance is responsible for the elevated intraocular pressure characteristic of glaucoma, but the cause of this resistance increase is not known. We tested the hypothesis that altered biomechanical behavior of Schlemm's canal (SC) cells contributes to this dysfunction. We used atomic force microscopy, optical magnetic twisting cytometry, and a unique cell perfusion apparatus to examine cultured endothelial cells isolated from the inner wall of SC of healthy and glaucomatous human eyes. Here we establish the existence of a reduced tendency for pore formation in the glaucomatous SC cell-likely accounting for increased outflow resistance-that positively correlates with elevated subcortical cell stiffness, along with an enhanced sensitivity to the mechanical microenvironment including altered expression of several key genes, particularly connective tissue growth factor. Rather than being seen as a simple mechanical barrier to filtration, the endothelium of SC is seen instead as a dynamic material whose response to mechanical strain leads to pore formation and thereby modulates the resistance to aqueous humor outflow. In the glaucomatous eye, this process becomes impaired. Together, these observations support the idea of SC cell stiffness-and its biomechanical effects on pore formation-as a therapeutic target in glaucoma.cell mechanics | primary open-angle glaucoma | modulus | cytoskeleton
Plaques vulnerable to rupture are characterized by a thin and stiff fibrous cap overlaying a soft lipid-rich necrotic core. The ability to measure local plaque stiffness directly to quantify plaque stress and predict rupture potential would be very attractive, but no current technology does so. This study seeks to validate the use of Brillouin microscopy to measure the Brillouin frequency shift, which is related to stiffness, within vulnerable plaques. The left carotid artery of an ApoE 2/2 mouse was instrumented with a cuff that induced vulnerable plaque development in nine weeks. Adjacent histological sections from the instrumented and control arteries were stained for either lipids or collagen content, or imaged with confocal Brillouin microscopy. Mean Brillouin frequency shift was 15.79 + 0.09 GHz in the plaque compared with 16.24 + 0.15 ( p , 0.002) and 17.16 + 0.56 GHz ( p , 0.002) in the media of the diseased and control vessel sections, respectively. In addition, frequency shift exhibited a strong inverse correlation with lipid area of 20.67 + 0.06 ( p , 0.01) and strong direct correlation with collagen area of 0.71 + 0.15 ( p , 0.05). This is the first study, to the best of our knowledge, to apply Brillouin spectroscopy to quantify atherosclerotic plaque stiffness, which motivates combining this technology with intravascular imaging to improve detection of vulnerable plaques in patients.
The bulk of aqueous humor passing through the conventional outflow pathway must cross the inner wall endothelium of Schlemm’s canal (SC), likely through micron-sized transendothelial pores. SC pore density is reduced in glaucoma, possibly contributing to obstructed aqueous humor outflow and elevated intraocular pressure (IOP). Little is known about the mechanisms of pore formation; however, pores are often observed near dome-like cellular outpouchings known as giant vacuoles (GVs) where significant biomechanical strain acts on SC cells. We hypothesize that biomechanical strain triggers pore formation in SC cells. To test this hypothesis, primary human SC cells were isolated from three non-glaucomatous donors (aged 34, 44 and 68), and seeded on collagen-coated elastic membranes held within a membrane stretching device. Membranes were then exposed to 0%, 10% or 20% equibiaxial strain, and the cells were aldehyde-fixed 5 minutes after the onset of strain. Each membrane contained 3–4 separate monolayers of SC cells as replicates (N = 34 total monolayers), and pores were assessed by scanning electron microscopy in 12 randomly selected regions (~65,000 μm2 per monolayer). Pores were identified and counted by four independent masked observers. Pore density increased with strain in all three cell lines (p < 0.010), increasing from 87±37 pores/mm2 at 0% strain to 342±71 at 10% strain; two of the three cell lines showed no additional increase in pore density beyond 10% strain. Transcellular “I-pores” and paracellular “B-pores” both increased with strain (p < 0.038), however B-pores represented the majority (76%) of pores. Pore diameter, in contrast, appeared unaffected by strain (p = 0.25), having a mean diameter of 0.40 μm for I-pores (N = 79 pores) and 0.67 μm for B-pores (N = 350 pores). Pore formation appears to be a mechanosensitive process that is triggered by biomechanical strain, suggesting that SC cells have the ability to modulate local pore density and filtration characteristics of the inner wall endothelium based on local biomechanical cues. The molecular mechanisms of pore formation and how they become altered in glaucoma may be studied in vitro using stretched SC cells.
The precise flow characteristics that promote different atherosclerotic plaque types remain unclear. We previously developed a blood flow-modifying cuff for ApoE−/− mice that induces the development of advanced plaques with vulnerable and stable features upstream and downstream of the cuff, respectively. Herein, we sought to test the hypothesis that changes in flow magnitude promote formation of the upstream (vulnerable) plaque, whereas altered flow direction is important for development of the downstream (stable) plaque. We instrumented ApoE−/− mice (n = 7) with a cuff around the left carotid artery and imaged them with micro-CT (39.6 µm resolution) eight to nine weeks after cuff placement. Computational fluid dynamics was then performed to compute six metrics that describe different aspects of atherogenic flow in terms of wall shear stress magnitude and/or direction. In a subset of four imaged animals, we performed histology to confirm the presence of advanced plaques and measure plaque length in each segment. Relative to the control artery, the region upstream of the cuff exhibited changes in shear stress magnitude only (p < 0.05), whereas the region downstream of the cuff exhibited changes in shear stress magnitude and direction (p < 0.05). These data suggest that shear stress magnitude contributes to the formation of advanced plaques with a vulnerable phenotype, whereas variations in both magnitude and direction promote the formation of plaques with stable features.
C oronary heart disease is projected to remain the worldwide leading cause of death until 2030.1 Coronary heart disease is a major cause of morbidity and reduced quality of life with enormous economic consequences.2,3 Atherosclerosis, a multifocal lipid-driven inflammatory process, is the principal underlying pathology in patients with coronary heart disease, which commonly presents clinically with symptoms secondary to luminal narrowing of an epicardial coronary artery or Background-Although disturbed flow is thought to play a central role in the development of advanced coronary atherosclerotic plaques, no causal relationship has been established. We evaluated whether inducing disturbed flow would cause the development of advanced coronary plaques, including thin cap fibroatheroma. Methods and Results-D374Y-PCSK9 hypercholesterolemic minipigs (n=5) were instrumented with an intracoronary shear-modifying stent (SMS). Frequency-domain optical coherence tomography was obtained at baseline, immediately poststent, 19 weeks, and 34 weeks, and used to compute shear stress metrics of disturbed flow. At 34 weeks, plaque type was assessed within serially collected histological sections and coregistered to the distribution of each shear metric. The SMS caused a flow-limiting stenosis, and blood flow exiting the SMS caused regions of increased shear stress on the outer curvature and large regions of low and multidirectional shear stress on the inner curvature of the vessel. As a result, plaque burden was ≈3-fold higher downstream of the SMS than both upstream of the SMS and in the control artery (P<0.001). Advanced plaques were also primarily observed downstream of the SMS, in locations initially exposed to both low (P<0.002) and multidirectional (P<0.002) shear stress. Thin cap fibroatheroma regions demonstrated significantly lower shear stress that persisted over the duration of the study in comparison with other plaque types (P<0.005). Conclusions-These data support a causal role for lowered and multidirectional shear stress in the initiation of advanced coronary atherosclerotic plaques. Persistently lowered shear stress appears to be the principal flow disturbance needed for the formation of thin cap fibroatheroma. an acute coronary syndrome. The latter is a major cause of coronary heart disease death and most commonly results from rupture at the site of a thin cap fibroatheroma (TCFA) leading to coronary thrombosis. 4The precise environmental cues that lead plaques toward an advanced and high-risk phenotype are not yet fully elucidated, but disturbed blood flow is thought to play a central role in both lesion initiation and progression.5 Disturbed flow is most frequently quantified by metrics of shear stress, which is the frictional force imposed by blood flowing over the endothelial surface, and association between these metrics and coronary atherosclerotic lesion stage have been demonstrated in vivo in both animal models 6-9 and patients. 10,11 However, few studies have investigated the impact of prevalent shear co...
Aqueous humour transport across the inner wall endothelium of Schlemm’s canal likely involves flow through giant vacuoles and pores, but the mechanics of how these structures form and how they influence the regulation of intraocular pressure (IOP) are not well understood. In this study, we developed an in vitro model of giant vacuole formation in human Schlemm’s canal endothelial cells (HSCECs) perfused in the basal-to-apical direction (i.e., the direction that flow crosses the inner wall in vivo) under controlled pressure drops (2 or 6 mmHg). The system was mounted on a confocal microscope for time-lapse en face imaging, and cells were stained with calcein, a fluorescent vital dye. At the onset of perfusion, elliptical void regions appeared within an otherwise uniformly stained cytoplasm, and 3-dimensional reconstructions revealed that these voids were dome-like outpouchings of the cell to form giant vacuole-like structures or GVLs that reproduced the classic “signet ring” appearance of true giant vacuoles. Increasing pressure drop from 2 to 6 mmHg increased GVL height (14 ± 4 vs. 21 ± 7 µm, p < 0.0001) and endothelial hydraulic conductivity (1.15 ± 0.04 vs. 2.11 ± 0.49 µL min−1 mmHg−1 cm−2; p < 0.001), but there was significant variability in the GVL response to pressure between cell lines isolated from different donors. During perfusion, GVLs were observed “migrating” and agglomerating about the cell layer and often collapsed despite maintaining the same pressure drop. GVL formation was also observed in human umbilical vein and porcine aortic endothelial cells, suggesting that giant vacuole formation is not a unique property of Schlemm’s canal cells. However, in these other cell types, GVLs were rarely observed “migrating” or contracting during perfusion, suggesting that Schlemm’s canal endothelial cells may be better adapted to withstand basal-to-apical directed pressure gradients. In conclusion, we have established an in vitro model system to study giant vacuole dynamics, and we have demonstrated that this system reproduces key aspects of giant vacuole morphology and behaviour. This model offers promising opportunities to investigate the role of endothelial cell biomechanics in the regulation of intraocular pressure in normal and glaucomatous eyes.
The lens capsule of the eye functions, in part, as a deformable support through which the ciliary body applies tractions that can alter lens curvature and corresponding refractive power during the process of accommodation. Although it has long been recognized that characterization of the mechanical properties of the lens capsule is fundamental to understanding this physiologic process as well as clinical interventions, prior data have been limited by one-dimensional testing of excised specimens despite the existence of multiaxial loading in vivo. In this paper, we employ a novel experimental approach to study in situ the regional, multiaxial mechanical behavior of both normal and diabetic human anterior lens capsules. Furthermore, we use these data to calculate material parameters in a nonlinear stress-strain relation via a custom sub-domain inverse finite element method (FEM). These parameters are then used to predict capsular stresses in response to imposed loads using a forward FEM model. Our results for both normal and diabetic human eyes show that the anterior lens capsule exhibits a nonlinear pseudoelastic behavior over finite strains that is typical of soft tissues, and that strains are principal relative to meridional and circumferential directions. Experimental data and parameter estimation suggest further that the capsule is regionally anisotropic, with the circumferential direction becoming increasingly stiffer than the meridional direction towards the equator. Although both normal and diabetic lens capsules exhibited these general characteristic behaviors, diabetic capsules were significantly stiffer at each distension. Finally, the forward FEM model predicted a nearly uniform, equibiaxial stress field during normalcy that will be perturbed by cataract surgery. Such mechanical perturbations may be an underlying modulator of the sustained errant epithelial cell behavior that is observed well after cataract surgery and may ultimately contribute to opacification of the posterior lens capsule.
This review provides an overview of the effect of blood flow on endothelial cell (EC) signalling pathways, applying microarray technologies to cultured cells, and in vivo studies of normal and atherosclerotic animals. It is found that in cultured ECs, 5-10% of genes are up- or down-regulated in response to fluid flow, whereas only 3-6% of genes are regulated by varying levels of fluid flow. Of all genes, 90% are regulated by the steady part of fluid flow and 10% by pulsatile components. The associated gene profiles show high variability from experiment to experiment depending on experimental conditions, and importantly, the bioinformatical methods used to analyse the data. Despite this high variability, the current data sets can be summarized with the concept of endothelial priming. In this concept, fluid flows confer protection by an up-regulation of anti-atherogenic, anti-thrombotic, and anti-inflammatory gene signatures. Consequently, predilection sites of atherosclerosis, which are associated with low-shear stress, confer low protection for atherosclerosis and are, therefore, more sensitive to high cholesterol levels. Recent studies in intact non-atherosclerotic animals confirmed these in vitro studies, and suggest that a spatial component might be present. Despite the large variability, a few signalling pathways were consistently present in the majority of studies. These were the MAPK, the nuclear factor-κB, and the endothelial nitric oxide synthase-NO pathways.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.