Summary Background Whole-body magnetic resonance imaging (WB-MRI) could be an alternative to multi-modality staging of non-small-cell lung cancer (NSCLC), but its diagnostic accuracy, effect on staging times, number of tests needed, cost, and effect on treatment decisions are unknown. We aimed to prospectively compare the diagnostic accuracy and efficiency of WB-MRI-based staging pathways with standard pathways in NSCLC. Methods The Streamline L trial was a prospective, multicentre trial done in 16 hospitals in England. Eligible patients were 18 years or older, with newly diagnosed NSCLC that was potentially radically treatable on diagnostic chest CT (defined as stage IIIb or less). Exclusion criteria were severe systemic disease, pregnancy, contraindications to MRI, or histologies other than NSCLC. Patients underwent WB-MRI, the result of which was withheld until standard staging investigations were complete and the first treatment decision made. The multidisciplinary team recorded its treatment decision based on standard investigations, then on the WB-MRI staging pathway (WB-MRI plus additional tests generated), and finally on all tests. The primary outcome was difference in per-patient sensitivity for metastases between standard and WB-MRI staging pathways against a consensus reference standard at 12 months, in the per-protocol population. Secondary outcomes were difference in per-patient specificity for metastatic disease detection between standard and WB-MRI staging pathways, differences in treatment decisions, staging efficiency (time taken, test number, and costs) and per-organ sensitivity and specificity for metastases and per-patient agreement for local T and N stage. This trial is registered with the International Standard Randomised Controlled Trial registry, number ISRCTN50436483, and is complete. Findings Between Feb 26, 2013, and Sept 5, 2016, 976 patients were screened for eligibility. 353 patients were recruited, 187 of whom completed the trial; 52 (28%) had metastasis at baseline. Pathway sensitivity was 50% (95% CI 37–63) for WB-MRI and 54% (41–67) for standard pathways, a difference of 4% (−7 to 15, p=0·73). No adverse events related to imaging were reported. Specificity did not differ between WB-MRI (93% [88–96]) and standard pathways (95% [91–98], p=0·45). Agreement with the multidisciplinary team's final treatment decision was 98% for WB-MRI and 99% for the standard pathway. Time to complete staging was shorter for WB-MRI (13 days [12–14]) than for the standard pathway (19 days [17–21]); a 6-day (4–8) difference. The number of tests required was similar WB-MRI (one [1–1]) and standard pathways (one [1–2]). Mean per-patient costs were £317 (273–361) for WBI-MRI and £620 (574–666) for standard pathways. Interpretation WB-MRI staging pathways have similar accuracy to standard pathways, and reduce the staging time and costs. Funding UK National Institute...
Background Whole-body MRI (WB-MRI) could be an alternative to multimodality staging of colorectal cancer, but its diagnostic accuracy, effect on staging times, number of tests needed, cost, and effect on treatment decisions are unknown. We aimed to prospectively compare the diagnostic accuracy and efficiency of WB-MRI-based staging pathways with standard pathways in colorectal cancer. Methods The Streamline C trial was a prospective, multicentre trial done in 16 hospitals in England. Eligible patients were 18 years or older, with newly diagnosed colorectal cancer. Exclusion criteria were severe systemic disease, pregnancy, contraindications to MRI, or polyp cancer. Patients underwent WB-MRI, the result of which was withheld until standard staging investigations were complete and the first treatment decision made. The multidisciplinary team recorded its treatment decision based on standard investigations, then on the WB-MRI staging pathway (WB-MRI plus additional tests generated), and finally on all tests. The primary outcome was difference in per-patient sensitivity for metastases between standard and WB-MRI staging pathways against a consensus reference standard at 12 months, in the per-protocol population. Secondary outcomes were difference in per-patient specificity for metastatic disease detection between standard and WB-MRI staging pathways, differences in treatment decisions, staging efficiency (time taken, test number, and costs), and per-organ sensitivity and specificity for metastases and per-patient agreement for local T and N stage. This trial is registered with the International Standard Randomised Controlled Trial registry, number ISRCTN43958015, and is complete.
INTRODUCTION The aim of this study was to conduct retrospective analysis of abdominopelvic computed tomography (CT) reports, identifying those patients in whom bowel wall thickening (BWT) was observed, and to correlate these reports with subsequent endoscopic evaluation. METHODS Formal reports for all patients undergoing abdominopelvic CT between February 2007 and September 2009 were reviewed. Where patients were identified as having colorectal 'wall thickening', results of subsequent endoscopic evaluations were documented. Only those patients with a report of BWT who had follow-up endoscopy (colonoscopy, sigmoidoscopy) were included in the analysis. RESULTS A total of 165 patients were included. Abnormalities on endoscopy at the exact site of the BWT on CT were found in 95 patients (57.58%); in 36 cases (21.82%) this was a malignant lesion. BWT of the transverse colon was significantly more likely to correspond to an endoscopic finding of cancer than other sites (p=0.034). Rectal bleeding was reported significantly more often in patients with BWT and neoplastic disease on endoscopy compared with those with normal endoscopy (p=0.04). Excluding patients with inflammatory/diverticular lesions, 59.02% of Caucasians had a neoplastic lesion at the site of reported BWT, significantly higher than the other ethnic groups (p=0.008). There were 38 patients (23.03%) who did not present with bowel symptoms and, of these, 6 were diagnosed subsequently with colorectal cancer. CONCLUSIONS This study supports endoscopic evaluation to investigate patients with CT evidence of BWT, especially in cases involving the transverse colon, in Caucasian patients or in association with symptoms of rectal bleeding.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.