Given the strong interdisciplinary nature of microfluidic immobilized enzyme reactor (μ-IMER) technology, several branches of science contribute to its successful implementation. A combination of physical, chemical knowledge and engineering skills is often required. The development and application of μ-IMERs in the proteomic community are experiencing increasing importance due to their attractive features of enzyme reusability, shorter digestion times, the ability to handle minute volumes of sample and the prospect of on-line integration into analytical workflows. The aim of this review is to give an account of the current (2017–2021) trends regarding the preparation of microdevices, immobilization strategies, and IMER configurations. The different aspects of microfabrication (designs, fabrication technologies and detectors) and enzyme immobilization (empty and packed channels, and monolithic supports) are surveyed focusing on μ-IMERs developed for proteomic analysis. Based on the advantages and limitations of the published approaches and the different applications, a probable perspective is given.
The goal of this paper was to develop an in-line immobilized enzyme reactor (IMER) integrated into a capillary electrophoresis platform. In our research, we created the IMER by adsorbing trypsin onto the inner surface of a capillary in a short section. Enzyme immobilization was possible due to the electrostatic attraction between the oppositely charged fused silica capillary surface and trypsin. The reactor was formed by simply injecting and removing trypsin solution from the capillary inlet (~1–2 cms). We investigated the factors affecting the efficiency of the reactor. The main advantages of the proposed method are the fast, cheap, and easy formation of an IMER with in-line protein digestion capability. Human tear samples were used to test the efficiency of the digestion in the microreactor.
A CZE-MS method was developed for the determination of several phenolic compounds (phenolic acids, flavonoids). Since the analysis of these components necessitates the application of basic conditions for CZE separation and negative ionization mode for MS detection, the simplest choice was to use 0.5 M NH4OH and IPA:water (1:1 v/v%) as the background electrolyte and sheath liquid, respectively. The LOD values ranged between 0.004–1.9 mg/L showing that there are relatively large differences in the ionization (and chemical) features of these compounds. The precision data were better than 0.75 RSD% for migration times and were between 5–8 RSD% for peak areas. In order to test the applicability of the developed method, a honey sample was analyzed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.