The purpose of this study was to assess the functional and prognostic correlates of B-lines during stress echocardiography (SE). BACKGROUND B-profile detected by lung ultrasound (LUS) is a sign of pulmonary congestion during SE. METHODS The authors prospectively performed transthoracic echocardiography (TTE) and LUS in 2,145 patients referred for exercise (n ¼ 1,012), vasodilator (n ¼ 1,054), or dobutamine (n ¼ 79) SE in 11 certified centers. B-lines were evaluated in a 4-site simplified scan (each site scored from 0: A-lines to 10: white lung for coalescing B-lines). During stress the following were also analyzed: stress-induced new regional wall motion abnormalities in 2 contiguous segments; reduced left ventricular contractile reserve (peak/rest based on force, #2.0 for exercise and dobutamine, #1.1 for vasodilators); and abnormal coronary flow velocity reserve #2.0, assessed by pulsed-wave Doppler sampling in left anterior descending coronary artery and abnormal heart rate reserve (peak/rest heart rate) #1.80 for exercise and dobutamine (#1.22 for vasodilators). All patients completed follow-up. RESULTS According to B-lines at peak stress patients were divided into 4 different groups: group I, absence of stress B-lines (score: 0 to 1; n ¼ 1,389; 64.7%); group II, mild B-lines (score: 2 to 4; n ¼ 428; 20%); group III, moderate B-lines (score: 5 to 9; n ¼ 209; 9.7%) and group IV, severe B-lines (score: $10; n ¼ 119; 5.4%). During median follow-up of 15.2 months (interquartile range: 12 to 20 months) there were 38 deaths and 28 nonfatal myocardial infarctions in 64 patients. At multivariable analysis, severe stress B-lines (hazard ratio [
With stress echo (SE) 2020 study, a new standard of practice in stress imaging was developed and disseminated: the ABCDE protocol for functional testing within and beyond CAD. ABCDE protocol was the fruit of SE 2020, and is the seed of SE 2030, which is articulated in 12 projects: 1-SE in coronary artery disease (SECAD); 2-SE in diastolic heart failure (SEDIA); 3-SE in hypertrophic cardiomyopathy (SEHCA); 4-SE post-chest radiotherapy and chemotherapy (SERA); 5-Artificial intelligence SE evaluation (AI-SEE); 6-Environmental stress echocardiography and air pollution (ESTER); 7-SE in repaired Tetralogy of Fallot (SETOF) ; 8-SE in post-COVID-19 (SECOV); 9: Recovery by stress echo of conventionally unfit donor good hearts (RESURGE); 10-SE for mitral ischemic regurgitation (SEMIR); 11-SE in valvular heart disease (SEVA); 12-SE for coronary vasospasm (SESPASM). The study aims to recruit in the next 5 years (2021–2025) ≥10,000 patients followed for ≥5 years (up to 2030) from ≥20 quality-controlled laboratories from ≥10 countries. In this COVID-19 era of sustainable health care delivery, SE2030 will provide the evidence to finally recommend SE as the optimal and versatile imaging modality for functional testing anywhere, any time, and in any patient.
Background: Lung ultrasound detects pulmonary congestion as B-lines at rest, and more frequently, during exercise stress echocardiography (ESE). Methods: We performed ESE plus lung ultrasound (4-site simplified scan) in 4392 subjects referred for semi-supine bike ESE in 24 certified centers in 9 countries. B-line score ranged from 0 (normal) to 40 (severely abnormal). Five different populations were evaluated: control subjects (n=103); chronic coronary syndromes (n=3701); heart failure with reduced ejection fraction (n=395); heart failure with preserved ejection fraction (n=70); ischemic mitral regurgitation ≥ moderate at rest (n=123). In a subset of 2478 patients, follow-up information was available. Results: During ESE, B-lines increased in all study groups except controls. Age, hypertension, abnormal ejection fraction, peak wall motion score index, and abnormal heart rate reserve were associated with B-lines in multivariable regression analysis. Stress B lines (hazard ratio, 2.179 [95% CI, 1.015–4.680]; P =0.046) and ejection fraction <50% (hazard ratio, 2.942 [95% CI, 1.268–6.822]; P =0.012) were independent predictors of all-cause death (n=29 after a median follow-up of 29 months). Conclusions: B-lines identify the pulmonary congestion phenotype at rest, and more frequently, during ESE in ischemic and heart failure patients. Stress B-lines may help to refine risk stratification in these patients. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT 03049995.
Functional testing with stress echocardiography is based on the detection of regional wall motion abnormality with two-dimensional echocardiography and is embedded in clinical guidelines. Yet, it under-uses the unique versatility of the technique, ideally suited to describe the different functional abnormalities underlying the same wall motion response during stress. Five parameters converge conceptually and methodologically in the state-of-the-art ABCDE protocol, assessing multiple vulnerabilities of the ischemic patient. The five steps of the ABCDE protocol are (1) step A: regional wall motion; (2) step B: B-lines by lung ultrasound assessing extravascular lung water; (3) step C: left ventricular contractile reserve by volumetric two-dimensional echocardiography; (4) step D: coronary flow velocity reserve in mid-distal left anterior descending coronary with pulsed-wave Doppler; and (5) step E: assessment of heart rate reserve with a one-lead electrocardiogram. ABCDE stress echo offers insight into five functional reserves: epicardial flow (A); diastolic (B), contractile (C), coronary microcirculatory (D), and chronotropic reserve (E). The new format is more comprehensive and allows better functional characterization, risk stratification, and personalized tailoring of therapy. ABCDE protocol is an ‘ecumenic’ and ‘omnivorous’ functional test, suitable for all stresses and all patients also beyond coronary artery disease. It fits the need for sustainability of the current era in healthcare, since it requires universally available technology, and is low-cost, radiation-free, and nearly carbon-neutral.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.