Background Supraphysiological hemodynamics are a recognized driver of platelet activation and thrombosis at high-grade stenosis and in blood contacting circulatory support devices. However, whether platelets mechano-sense hemodynamic parameters directly in free flow (in the absence of adhesion receptor engagement), the specific hemodynamic parameters at play, the precise timing of activation, and the signaling mechanism(s) involved remain poorly elucidated. Results Using a generalized Newtonian computational model in combination with microfluidic models of flow acceleration and quasi-homogenous extensional strain, we demonstrate that platelets directly mechano-sense acute changes in free-flow extensional strain independent of shear strain, platelet amplification loops, von Willebrand factor, and canonical adhesion receptor engagement. We define an extensional strain sensing “mechanosome” in platelets involving cooperative Ca2+ signaling driven by the mechanosensitive channel Piezo1 (as the primary strain sensor) and the fast ATP gated channel P2X1 (as the secondary signal amplifier). We demonstrate that type II PI3 kinase C2α activity (acting as a “clutch”) couples extensional strain to the mechanosome. Conclusions Our findings suggest that platelets are adapted to rapidly respond to supraphysiological extensional strain dynamics, rather than the peak magnitude of imposed wall shear stress. In the context of overall platelet activation and thrombosis, we posit that “extensional strain sensing” acts as a priming mechanism in response to threshold levels of extensional strain allowing platelets to form downstream adhesive interactions more rapidly under the limiting effects of supraphysiological hemodynamics.
Von Willebrand's disease (VWD) is the most common inherited bleeding disorder caused by either quantitative or qualitative defects of von Willebrand factor (VWF). Current tests for VWD require relatively large blood volumes, have low throughput, are time-consuming, and do not incorporate the physiologically relevant effects of haemodynamic forces. We developed a microfluidic device incorporating micro-contractions that harnesses well-defined haemodynamic strain gradients to initiate platelet aggregation in citrated whole blood. The microchannel architecture has been specifically designed to allow for continuous real-time imaging of platelet aggregation dynamics. Subjects aged ≥18 years with previously diagnosed VWD or who presented for evaluation of a bleeding disorder, where the possible diagnosis included VWD, were tested. Samples were obtained for device characterization as well as for pathology-based testing. Platelet aggregation in the microfluidic device is independent of platelet amplification loops but dependent on low-level platelet activation, GPIb/IX/V and integrin αβ engagement. Microfluidic output directly correlates with VWF antigen levels and is able to sensitively detect aggregation defects associated with VWD subtypes. Testing demonstrated a strong correlation with standard clinical laboratory-based tests. Head-to-head comparison with PFA100® demonstrated equivalent, if not improved, sensitivity for screening aggregation defects associated with VWD. This strain rate gradient microfluidic prototype has the potential to be a clinically useful, rapid and high throughput-screening tool for VWD as well as other strain-dependent platelet disorders. In addition, the microfluidic device represents a novel approach to examine the effects of high magnitude/short duration (ms) strain rate gradients on platelet function.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.