The ANTARES neutrino telescope is being constructed in the Mediterranean Sea. It consists of a large three-dimensional array of photo-multiplier tubes. The data acquisition system of the detector takes care of the digitisation of the photo-multiplier tube signals, data transport, data filtering, and data storage. The detector is operated using a control program interfaced with all elements. The design and the implementation of the data acquisition system are described.
The normal growth pattern of female C57BL/6J mice, from 5 to 30 weeks of age, has been investigated in a longitudinal study. Weight, body surface area (BS), and body mass index (BMI) were evaluated in forty mice. Lean mass and fat mass, bone mineral content (BMC), and bone mineral density (BMD) were monitored by dual energy X-ray absorptiometry (DEXA). Weight and BS increased linearly (16.15 ± 0.64–27.64 ± 1.42 g; 51.13 ± 0.74–79.57 ± 2.15 cm2, P < 0.01), more markedly from 5 to 9 weeks of age (P < 0.001). BMD showed a peak at 17 weeks (0.0548 ± 0.0011 g/cm2∗ m, P < 0.01). Lean mass showed an evident gain at 9 (15.8 ± 0.8 g, P < 0.001) and 25 weeks (20.5 ± 0.3 g, P < 0.01), like fat mass from 13 to 17 weeks (2.0 ± 0.4–3.6 ± 0.7 g, P < 0.01). BMI and lean mass index (LMI) reached the highest value at 21 weeks (3.57 ± 0.02–0.284 ± 0.010 g/cm2, resp.), like fat mass index (FMI) at 17 weeks (0.057 ± 0.009 g/cm2) (P < 0.01). BMI, weight, and BS showed a moderate positive correlation (0.45–0.85) with lean mass from 5 to 21 weeks. Mixed linear models provided a good prediction for lean mass, fat mass, and BMD. This study may represent a baseline reference for a future comparison of wild-type C57BL/6J mice with models of altered growth.
The NEMO (NEutrino Mediterranean Observatory) Collaboration has been carrying out since 1998 an evaluation programme of deep sea sites suitable for the construction of the future Mediterranean km3 Čerenkov neutrino telescope. We investigated the seawater optical and oceanographic properties of several deep sea marine areas close to the Italian Coast. Inherent optical properties (light absorption and attenuation coefficients) have been measured as a function of depth using an experimental apparatus equipped with standard oceanographic probes and the commercial transmissometer AC9 manufactured by WETLabs. This paper reports on the visible light absorption and attenuation coefficients measured in deep seawater of a marine region located in the Southern Ionian Sea, 60 100 km SE of Capo Passero (Sicily). Data show that blue light absorption coefficient is about 0.015 m-1 (corresponding to an absorption length of 67 m) close to the one of optically pure water and it does not show seasonal variation
18 pages, 12 figures, submitted to Astroparticle PhysicsIn 2005, the ANTARES Collaboration deployed and operated at a depth of 2500 m a so-called Mini Instrumentation Line equipped with Optical Modules (MILOM) at the ANTARES site. The various data acquired during the continuous operation from April to December 2005 of the MILOM confirm the satisfactory performance of the Optical Modules, their front-end electronics and readout system, as well as the calibration devices of the detector. The in-situ measurement of the Optical Module time response yields a resolution better than 0.5 ns. The performance of the acoustic positioning system, which enables the spatial reconstruction of the ANTARES detector with a precision of about 10 cm, is verified. These results demonstrate that with the full ANTARES neutrino telescope the design angular resolution of better than $0.3^\circ$ can be realistically achieved
ANTARES is a neutrino telescope being deployed in the Mediterranean Sea. It consists of a three-dimensional array of photomultiplier tubes that can detect the Cherenkov light induced by charged particles produced in the interactions of neutrinos with the surrounding medium. High angular resolution can be achieved, in particular, when a muon is produced, provided that the Cherenkov photons are detected with sufficient timing precision. Considerations of the intrinsic time uncertainties stemming from the transit time spread in the photomultiplier tubes and the mechanism of transmission of light in sea water lead to the conclusion that a relative time accuracy of the order of 0.5 ns is desirable. Accordingly, different time calibration systems have been developed for the ANTARES telescope. In this article, a system based on Optical Beacons, a set of external and well-controlled pulsed light sources located throughout the detector, is described. This calibration system takes into account the optical properties of sea water, which is used as the detection volume of the ANTARES telescope. The design, tests, construction and first results of the two types of beacons, LED and laser-based, are presented. (C) 2007 Elsevier B.V. All rights reserved
Purpose
We assessed the effects of the COVID-19 pandemic on myocardial perfusion imaging (MPI) for ischemic heart disease during the lockdown imposed by the Italian Government.
Methods
We retrospectively reviewed the number and the findings of stress single-photon emission computed tomography (SPECT)-MPI performed between February and May 2020 during the COVID-19 pandemic at the University of Napoli Federico II. The number and the findings of stress SPECT-MPI studies acquired in the corresponding months of the years 2017, 2018, and 2019 were also evaluated for direct comparison.
Results
The number of stress SPECT-MPI studies performed during the COVID-19 pandemic (
n
= 123) was significantly lower (
P
< 0.0001) compared with the mean yearly number of procedures performed in the corresponding months of the years 2017, 2018, and 2019 (
n
= 413). Yet, the percentage of abnormal stress SPECT-MPI studies was similar (
P
= 0.65) during the pandemic (36%) compared with the mean percentage value of the corresponding period of the years 2017, 2018, and 2019 (34%).
Conclusion
The number of stress SPECT-MPI studies was significantly reduced during the COVID-19 pandemic compared with the corresponding months of the previous 3 years. The lack of difference in the prevalence of abnormal SPECT-MPI studies between the two study periods strongly suggests that many patients with potentially abnormal imaging test have been missed during the pandemic.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.