BackgroundIn light of declining autopsy rates around the world, post-mortem MR imaging is a promising alternative to conventional autopsy in the investigation of infant death. A major drawback of this non-invasive autopsy approach is the fact that histopathological and microbiological examination of the tissue is not possible. The objective of this prospective study is to compare the performance of minimally invasive, virtual autopsy, including CT-guided biopsy, with conventional autopsy procedures in a paediatric population.Methods/DesignFoetuses, newborns and infants that are referred for autopsy at three different institutions associated with the University of Zurich will be eligible for recruitment. All bodies will be examined with a commercial CT and a 3 Tesla MRI scanner, masked to the results of conventional autopsy. After cross-sectional imaging, CT-guided tissue sampling will be performed by a multifunctional robotic system (Virtobot) allowing for automated post-mortem biopsies. Virtual autopsy results will be classified with regards to the likely final diagnosis and major pathological findings and compared to the results of conventional autopsy, which remains the diagnostic gold standard.DiscussionThere is an urgent need for the development of alternative post-mortem examination methods, not only as a counselling tool for families and as a quality control measure for clinical diagnosis and treatment but also as an instrument to advance medical knowledge and clinical practice. This interdisciplinary study will determine whether virtual autopsy will narrow the gap in information between non-invasive and traditional autopsy procedures.Trial RegistrationClinicalTrials.gov: NCT01888380
In this paper we present the second prototype of a robotic system to be used in forensic medicine. The system is capable of performing automated surface documentation using photogrammetry, optical surface scanning and image-guided, post-mortem needle placement for tissue sampling, liquid sampling, or the placement of guide wires. The upgraded system includes workflow optimizations, an automatic tool-change mechanism, a new software module for trajectory planning and a fully automatic computed tomography-data-set registration algorithm. We tested the placement accuracy of the system by using a needle phantom with radiopaque markers as targets. The system is routinely used for surface documentation and resulted in 24 surface documentations over the course of 11 months. We performed accuracy tests for needle placement using a biopsy phantom, and the Virtobot placed introducer needles with an accuracy of 1.4 mm (±0.9 mm). The second prototype of the Virtobot system is an upgrade of the first prototype but mainly focuses on streamlining the workflow and increasing the level of automation and also has an easier user interface. These upgrades make the Virtobot a potentially valuable tool for case documentation in a scalpel-free setting that uses purely imaging techniques and minimally invasive procedures and is the next step toward the future of virtual autopsy.
Postmortem CT for investigating childhood deaths is increasingly utilised as a noninvasive adjunct or alternative to standard autopsy; however there are no standardised published imaging protocols. This article describes a standardised imaging protocol that has been developed based on current practices of international postmortem imaging practitioners and experts. This recommendation is expected to be useful for postmortem imaging centres wishing to update their existing practices and for those starting paediatric postmortem CT as a new service.
CT-guided, minimally invasive needle biopsy techniques can be used to retrieve tissue or body fluid samples for histologic tissue diagnoses in forensic investigations. The purpose of this study was an evaluation of CT-guided needle-positioning robot B-Rob II. To operate under CT guidance, we adopted the B-Rob II robotic needle placement system and its workflow. The accuracy and speed of the procedure were tested on a gelatin phantom in a series of 21 biopsies. We achieved an average needle placement accuracy of 1.8 mm (±1.1 mm) using robotic assistance. The procedure required an average of 2 min 21 s. The needle placement accuracy for minimally invasive needle biopsies using the B-Rob II biopsy robot is sufficiently accurate and fast for forensic postmortem examinations of focal organ changes. Further tests will be performed to test the feasibility of the robot for performing biopsies of focal organ changes in human bodies.
The postmortem redistribution (PMR) phenomenon complicates interpretation in forensic toxicology. Human data on time-dependent PMR are rare and only exist for blood so far. A new method for investigation of time-dependent PMR in blood as well as in alternative body fluids and tissues was developed and evaluated using automated biopsy sampling. At admission of the bodies, introducer needles were placed in liver, lung, kidney, muscle, spleen, adipose tissue, heart, femoral vein, and lumbar spine using a robotic arm guided by a computed tomography scanner (CT). Needle placement accuracy was analyzed and found to be acceptable for the study purpose. Tissue biopsies and small volume body fluid samples were collected in triplicate through the introducer needles. At autopsy (around 24 h after admission), samples from the same body regions were collected. After mastering of the technical challenges, two authentic cases were analyzed as a proof of concept. Drug concentrations of venlafaxine, O-desmethylvenlafaxine, bromazepam, flupentixol, paroxetine, and lorazepam were determined by LC-MS/MS, and the percentage concentration changes between the two time points were calculated. Concentration changes were observed with both increases and decreases depending on analyte and matrix. While venlafaxine, flupentixol, paroxetine, and lorazepam generally showed changes above 30% and more, O-desmethylvenlafaxine and bromazepam did not undergo extensive PMR. The presented study shows that CT-controlled biopsy collection provides a valuable tool for systematic time-dependent PMR investigation, demanding only minimal sample amount and causing minimal damage to the body.
A man killed his wife and their shared household cats before killing himself. The combination of the killing (suicide or homicide) of a family member and the pet is seen on occasions in forensic pathology. The purpose of this case report is to provide a comparison of the killing methods of animals, ill pets and of household animals, also in extended suicides or homicides given the initially outlined case.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.