We present a highly sensitive room-temperature atomic magnetometer (AM), designed for use in biomedical applications. The magnetometer sensor head is only 2×2×5 cm3 and is constructed using readily available, low-cost optical components. The magnetic field resolution of the AM is <10 fT/√Hz, which is comparable to cryogenically cooled superconducting quantum interference device (SQUID) magnetometers. We present side-by-side comparisons between our AM and a SQUID magnetometer, and show that equally high quality magnetoencephalography (MEG) and magnetocardiography (MCG) recordings can be obtained using our AM.
The human fetal heart develops arrhythmias and conduction disturbances in response to ischemia, inflammation, electrolyte disturbances, altered load states, structural defects, inherited genetic conditions, and many other causes. Yet sinus rhythm is present without altered rate or rhythm in some of the most serious electrophysiological diseases, which makes detection of diseases of the fetal conduction system challenging in the absence of magnetocardiographic or electrocardiographic recording techniques. Life-threatening changes in QRS or QT intervals can be completely unrecognized if heart rate is the only feature to be altered. For many fetal arrhythmias, echocardiography alone can assess important clinical parameters for diagnosis. Appropriate treatment of the fetus requires awareness of arrhythmia characteristics, mechanisms, and potential associations. Criteria to define fetal bradycardia specific to gestational age are now available and may allow detection of ion channelopathies, which are associated with fetal and neonatal bradycardia. Ectopic beats, once thought to be entirely benign, are now recognized to have important pathologic associations. Fetal tachyarrhythmias can now be defined precisely for mechanism-specific therapy and for subsequent monitoring of response. This article reviews the current and future diagnostic techniques and pharmacologic treatments for fetal arrhythmia.
Background-Using fetal magnetocardiography (fMCG), we characterize for the first time the electrophysiological patterns of initiation and termination of reentrant fetal supraventricular tachycardia (SVT), the most common form of life-threatening fetal arrhythmia. Methods and Results-In contrast to the expectation that reentrant SVT is initiated by spontaneous premature atrial contractions (PACs) and is terminated by spontaneous block, 5 distinct patterns of initiation and 4 patterns of termination were documented, with the most common patterns of initiation involving reentrant PACs. Waveform morphology and timing, including QRS and ventriculoatrial interval, were assessed. This enabled detection of such phenomena as Wolff-Parkinson-White syndrome, QRS aberrancy, and multiple reentrant pathways that were crucial for defining the rhythm patterns. In addition, fMCG actocardiography revealed an unexpectedly strong association between fetal trunk movement and the initiation and termination of SVT, suggesting that autonomic influences play a key role. Conclusions-This study demonstrates that the patterns of initiation and termination of fetal SVT are more diverse than is generally believed and that the most common patterns of initiation involve reentrant PACs. The ability to discern such patterns can help elucidate the underlying mechanisms and guide antiarrhythmic drug therapy. fMCG provides a noninvasive means of analyzing complex tachyarrhythmia in utero, with efficacy approaching that of postnatal electrocardiographic rhythm monitoring.
Second-degree AVB, isolated 3 degrees AVB, and 3 degrees AVB associated with structural cardiac disease manifest distinctly different electrophysiological characteristics and outcome. Fetuses with 2 degrees AVB or isolated 3 degrees AVB commonly exhibited complex, changing heart rate and rhythm patterns; all 19 delivered fetuses are alive and healthy. Fetuses with structural cardiac disease and 3 degrees AVB exhibited largely monotonous heart rate and rhythm patterns and poor prognosis. Junctional ectopic tachycardia and/or ventricular tachycardia may be characteristic of an acute stage of heart block.
Detection and careful stratification of fetal heart rate (FHR) is extremely important in all pregnancies. The most lethal cardiac rhythm disturbances occur during apparently normal pregnancies where FHR and rhythmare regular and within normal or low-normal ranges. These hidden depolarization and repolarization abnormalities, associated with genetic ion channelopathies cannot be detected by echocardiography, and may be responsible for up to 10% of unexplained fetal demise, prompting a need for newer and better fetal diagnostic techniques. Other manifest fetal arrhythmias such as premature beats, tachycardia, and bradycardia are commonly recognized. Heart rhythm diagnosis in obstetrical practice is usually made by M-mode and pulsed Doppler fetal echocardiography, but not all fetal cardiac time intervals are captured by echocardiographic methods. This article reviews different types of fetal arrhythmias, their presentation and treatment strategies, and gives an overview of the present and future diagnostic techniques.
Background The electrophysiology of long QT syndrome (LQTS) in utero is virtually unstudied. Our goal here was to evaluate the efficacy of fetal magnetocardiography (fMCG) for diagnosis and prognosis of fetuses at risk of LQTS. Methods and Results We reviewed the pre/postnatal medical records of 30 fetuses referred for fMCG due to a family history of LQTS (n=17); neonatal/childhood sudden cardiac death (n=3) and/or presentation of prenatal LQTS rhythms (n=12): 2° AVB, ventricular tachycardia, heart rate < 3rd percentile. We evaluated heart rate and reactivity, cardiac time intervals, T-wave characteristics, and initiation/termination of Torsade de Pointes (TdP), and compared these with neonatal ECG findings. After birth, subjects were tested for LQTS mutations. Based on accepted clinical criteria, 21 subjects (70%; 9 KCNQ1, 5 KCNH2, 2 SCN5A, 2 other, 3 untested) had LQTS. Using a threshold of QTc= 490 ms, fMCG accurately identified LQTS fetuses with 89% (24/27) sensitivity and 89% (8/9) specificity in 36 sessions. Four fetuses (2 KCNH2 and 2 SCN5A), all with QTc ≥ 620 ms, had frequent episodes of TdP, which were present 22–79% of the time. While some episodes initiated with a long-short sequence, most initiations showed QRS aberrancy and a notable lack of pause dependency. T-wave alternans was strongly associated with severe LQTS phenotype. Conclusions QTc prolongation (≥490 ms) assessed by fMCG accurately identified LQTS in utero; extreme QTc prolongation (≥620 ms) predicted TdP. FMCG can play a critical role in the diagnosis and management of fetuses at risk of LQTS.
A new source model for representing spatially distributed neural activity is presented. The signal of interest is modeled as originating from a patch of cortex and is represented using a set of basis functions. Each cortical patch has its own set of bases, which allows representation of arbitrary source activity within the patch. This is in contrast to previously proposed cortical patch models which assume a specific distribution of activity within the patch. We present a procedure for designing bases that minimize the normalized mean squared representation error, averaged over different activity distributions within the patch. Extension of existing algorithms to the basis function framework is straightforward and is illustrated using linearly constrained minimum variance (LCMV) spatial filtering and maximum-likelihood signal estimation/generalized likelihood ratio test (ML/GLRT). The number of bases chosen for each patch determines a tradeoff between representation accuracy and the ability to differentiate between distinct patches. We propose choosing the minimum number of bases that satisfy a constraint on the normalized mean squared representation accuracy. A mismatch analysis for LCMV and ML/GLRT is presented to show that this is an appropriate strategy for choosing the number of bases. The effectiveness of the patch basis model is demonstrated using real and simulated evoked response data. We show that significant changes in performance occur as the number of basis functions varies, and that very good results are obtained by allowing modest representation error.
We describe an array of spin-exchange-relaxation-free optical magnetometers designed for detection of fetal magnetocardiography (fMCG). The individual magnetometers are configured with a small volume with intense optical pumping, surrounded by a large pump-free region. Spin-polarized atoms that diffuse out of the optical pumping region precess in the ambient magnetic field and are detected by a probe laser. Four such magnetometers, at the corners of a 7 cm square, are configured for gradiometry by feeding back the output of one magnetometer to a field coil to null uniform magnetic field noise at frequencies up to 200 Hz. We present the first measurements of fMCG signals using an atomic magnetometer.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.