In the current COVID-19 pandemic, a significant proportion of cases shed SARS-Coronavirus-2 (SARS-CoV-2) with their faeces. To determine if SARS-CoV-2 RNA was present in sewage during the emergence of COVID-19 in The Netherlands, sewage samples of six cities and the airport were tested using four qRT-PCR assays, three targeting the nucleocapsid gene (N1−N3) and one the envelope gene (E). No SARS-CoV-2 RNA was detected on February 6, 3 weeks before the first Dutch case was reported. On March 4/5, one or more gene fragments were detected in sewage of three sites, in concentrations of 2.6−30 gene copies per mL. In Amersfoort, N3 was detected in sewage 6 days before the first cases were reported. As the prevalence of COVID-19 in these cities increased in March, the RNA signal detected by each qRT-PCR assay increased, for N1−N3 up to 790−2200 gene copies per mL. This increase correlated significantly with the increase in reported COVID-19 prevalence. The detection of the virus RNA in sewage, even when the COVID-19 prevalence is low, and the correlation between concentration in sewage and reported prevalence of COVID-19, indicate that sewage surveillance could be a sensitive tool to monitor the circulation of the virus in the population.
In the current COVID-19 pandemic, a significant proportion of cases shed SARS-Coronavirus-2 (SARS-CoV-2) with their faeces. To determine if SARS-CoV-2 is present in sewage during the emergence of COVID-19 in the Netherlands, sewage samples of 7 cities and the airport were tested using RT-PCR against three fragments of the nucleocapsid protein gene (N1-3) and one fragment of the envelope protein gene (E). No SARS-CoV-2 was detected in samples of February 6, three weeks before the first case was reported in the Netherlands on February 27. On March 5, the N1 fragment was detected in sewage of five sites. On March 15/16, the N1 fragment was detected in sewage of six sites, and the N3 and E fragment were detected at 5 and 4 sites respectively. This is the first report of detection of SARS-CoV-2 in sewage. The detection of the virus in sewage, even when the COVID-19 prevalence is low, indicates that sewage surveillance could be a sensitive tool to monitor the circulation of the virus in the population.
ObjectiveThe goal of the current study was to gain insight into the prevalence and concentrations of antimicrobial resistant (AMR) Escherichia coli in Dutch surface water, and to explore the role of wastewater as AMR contamination source.MethodsThe prevalence of AMR E. coli was determined in 113 surface water samples obtained from 30 different water bodies, and in 33 wastewater samples obtained at five health care institutions (HCIs), seven municipal wastewater treatment plants (mWWTPs), and an airport WWTP. Overall, 846 surface water and 313 wastewater E. coli isolates were analysed with respect to susceptibility to eight antimicrobials (representing seven different classes): ampicillin, cefotaxime, tetracycline, ciprofloxacin, streptomycin, sulfamethoxazole, trimethoprim, and chloramphenicol.ResultsAmong surface water isolates, 26% were resistant to at least one class of antimicrobials, and 11% were multidrug-resistant (MDR). In wastewater, the proportions of AMR/MDR E. coli were 76%/62% at HCIs, 69%/19% at the airport WWTP, and 37%/27% and 31%/20% in mWWTP influents and effluents, respectively. Median concentrations of MDR E. coli were 2.2×102, 4.0×104, 1.8×107, and 4.1×107 cfu/l in surface water, WWTP effluents, WWTP influents and HCI wastewater, respectively. The different resistance types occurred with similar frequencies among E. coli from surface water and E. coli from municipal wastewater. By contrast, among E. coli from HCI wastewater, resistance to cefotaxime and resistance to ciprofloxacin were significantly overrepresented compared to E. coli from municipal wastewater and surface water. Most cefotaxime-resistant E. coliisolates produced ESBL. In two of the mWWTP, ESBL-producing variants were detected that were identical with respect to phylogenetic group, sequence type, AMR-profile, and ESBL-genotype to variants from HCI wastewater discharged onto the same sewer and sampled on the same day (A1/ST23/CTX-M-1, B23/ST131/CTX-M-15, D2/ST405/CTX-M-15).ConclusionIn conclusion, our data show that MDR E. coli are omnipresent in Dutch surface water, and indicate that municipal wastewater significantly contributes to this occurrence.
Concentration of water samples is a prerequisite for the detection of the low virus levels that are present in water and may present a public health hazard. The aim of this study was to develop a rapid, standardized molecular method for the detection of enteroviruses in large-volume surface water samples, using a concentration method suitable for the detection of infectious viruses as well as virus RNA. Concentration of water was achieved by a conventional filter adsorption-elution method and ultrafiltration, resulting in a 10,000-fold concentration of the sample. Isolation of virus RNA by a silica-based RNA extraction method was compared with the nonmagnetic and magnetic NucliSens RNA isolation methods. By using the silica-based RNA extraction method in two out of five samples, enterovirus RNA was detected, whereas four out of five samples were positive following RNA isolation with magnetic silica beads. Moreover, estimated RNA levels increased at least 100 to 500 times. Furthermore, we compared enterovirus detection by an in-house reverse transcription (RT)-PCR with a novel commercially available real-time nucleic acid sequence-based amplification (NASBA) assay. We found that the rapid real-time NASBA assay was slightly less sensitive than our in-house RT-PCR. The advantages, however, of a commercial real-time NASBA assay, like the presence of an internal control RNA, standardization, and enormous decrease in turnaround time, makes it an attractive alternative to RT-PCR.
The use of roof-collected rainwater as a freely available and sustainable alternative to drinking water produced by drinking water companies increases worldwide. Initially, rainwater is free of microbial contamination, but it may become contaminated by animals and humans or, alternatively, human pathogens may grow in stored rainwater resulting in a significant human health risk from infectious diseases. This three-year study demonstrated that rainwater stored in different reservoirs in The Netherlands was frequently faecally contaminated and incidentally contained potential human pathogens such as Campylobacter, Cryptosporidium, Giardia, Aeromonas hydrophila and Legionella.Analysis of samples during a period with variable weather conditions showed a correlation between rainfall intensity and faecal indicator counts and increased detection of pathogens after heavy rainfall incidents. Outside temperature had a limited effect on both the temperature and the microbiological quality of the water in the reservoirs, which did not comply with Dutch drinking water legislation and should thus not be consumed without treatment. In general, a health risk may arise from exposure to pathogens when contaminated droplets are inhaled, ingested or come into contact with the skin. Health risks may be reduced by regular cleaning of the collection, storage and transport means, but to assess their efficacy field intervention studies are required.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.