The Bonebridge is a transcutaneous alternative to the well-established percutaneous bone conducting devices in patients with single sided deafness. An improvement in hearing in noise and quiet as well as a decrease of the head shadow effect can be expected.
The coupling between FMT and RW membrane was improved by the application of static RW preloads as indicated by increased SFP amplitudes to RW stimulation.
This work assesses the efficiency of the Codacs system actuator (Cochlear Ltd., Sydney Australia) in different inner ear stimulation modalities. Originally the actuator was intended for direct perilymph stimulation after stapedotomy using a piston prosthesis. A possible alternative application is the stimulation of middle ear structures or the round window (RW). Here the perilymph stimulation with a K-piston through a stapes footplate (SFP) fenestration (N = 10) as well as stimulation of the stapes head (SH) with a Bell prosthesis (N = 9), SFP stimulation with an Omega/Aerial prosthesis (N = 8) and reverse RW stimulation (N = 10) were performed in cadaveric human temporal bones (TBs). Codacs actuator output is expressed as equivalent sound pressure level (eq. SPL) using RW and SFP displacement responses, measured by Laser Doppler velocimetry as reference. The axial actuator coupling force in stimulation of stapes and RW was adjusted to ~ 5 mN. The Bell prosthesis and Omega/Aerial prosthesis stimulation generated similar mean eq. SPLs (Bell: 127.5–141.8 eq. dB SPL; Omega/Aerial: 123.6–143.9 eq. dB SPL), being significantly more efficient than K-piston perilymph stimulation (108.6–131.6 eq. dB SPL) and RW stimulation (108.3–128.2 eq. dB SPL). Our results demonstrate that SH, SFP and RW are adequate alternative stimulation sites for the Codacs actuator using coupling prostheses and an axial coupling force of ~ 5 mN. Based on the eq. SPLs, all investigated methods were adequate for in vivo hearing aid applications, provided that experimental conditions including constant coupling force will be implemented.
Objectives: The principal aim of this study was to assess the safety and effectiveness of the middle ear implant Vibrant Soundbridge (VSB) in patients with moderate-to-severe sensorineural hearing loss up to a mean (± standard deviation) duration of 11.1 ± 2.1 years (min. = 8.2, max. = 13.9, n = 16) after the intervention. Design: This was a retrospective, single-subject repeated-measurements study over a long-term period. A total of 104 German-speaking adults (for 122 implants) were included in this study (54 male, 50 female). The mean age at implantation was 54.5 years (min. = 19.0, max. = 80.4). Audiological outcome and speech intelligibility were assessed in all VSB patients at different time points in non-overlapping groups. Results: Bone conduction (BC) thresholds were preserved after the implantation and no indication was found of an increase over time of the small air-bone gaps introduced by the implantation. BC and air conduction thresholds worsened similarly in both implanted and non-implanted ears over time. The decrease in audiological benefit provided by the VSB was moderate and the Word Recognition Score in quiet conditions at 65 dB SPL was still largely improved with the VSB in the longest observed group. Conclusions: These results confirm that the VSB does not affect the integrity of the inner/middle ear and is still beneficial in long-term follow-up.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.